Screening techniques have been widely deployed in industrial production for the size-separation of granular materials such as coal. The elliptical vibrating screen has been regarded as an excellent screening apparatus in terms of its high screening efficiency and large processing capacity. However, its fundamental mechanisms and operational principles remain poorly understood. In this paper, the sieving process of an elliptical vibrating screen was numerically simulated based on the discrete element method (DEM), and an approach coupling the DEM and the finite element method (DEM–FEM) was introduced to further explore the collision impact of materials on the screen deck. The screening time, screening efficiency, maximum stress and maximum deformation were examined for the evaluation of sieving performance. The effects of six parameters—length of the semi-major axis, length ratio between two semi-axes, vibration frequency, inclination angle, vibration direction angle and vibration direction—on different sieving results were systematically investigated in univariate and multivariate experiments. Additionally, the relationships among the four performance indexes were discussed and the relational functions were obtained. The conclusions and methodologies presented in this work could be of great significance for the design and improvement of elliptical vibrating screens.
Stroke rehabilitation with the assistance of exoskeleton robots has the potential to facilitate the recovery of motor skills by guiding, supporting, and encouraging movement in the affected limbs. In this work, an upper-extremity exoskeleton actuated by the cable transmission mechanism, was developed for rehabilitation training of stroke patients. The exoskeleton is designed with three DOFs, including shoulder abduction/adduction, shoulder flexion/extension, and elbow flexion/extension. The main body of exoskeleton is comprised of three links and two cuffs, with a total weight of approximately 1.7 kg. Based on the mechanical design and cable arrangement, the kinematics and dynamics of the actuation cables are analyzed. In addition, a PID-based position control strategy and an impedance control strategy are designed based on the cable kinematics and dynamics. To investigate the application performance in passive motion assistance, a prototype of the cable-driven exoskeleton system was established, and the corresponding experiments were conducted with five subjects. In position control experiments, the measured joint trajectories exhibit similar variation trends and close peek angles to the demonstration trajectory, which is the main emphasis in rehabilitation scenarios. Meanwhile, it can be inferred that the time lag is the primary reason for the tracking error between the expected and measured trajectories. As to the impedance control experiments, the statistical results indicate that the employment of lower impedance parameters tends to protect the human-robot interaction safety by sacrificing the tracking accuracy of joint position.
The application of exoskeleton robots has demonstrated promising effectiveness in promoting the recovery of motor skills in patients with upper limb dysfunction. However, the joint misalignment caused by rigid exoskeletons usually leads to an uncomfortable experience for users. In this work, an adaptive cable-driven elbow exoskeleton inspired by the structural characteristics of the shrimp shell was developed to facilitate the rehabilitation of the elbow joint and to provide more compliant human-exoskeleton interactions. The exoskeleton was specifically designed for elbow flexion and extension, with a total weight of approximately 0.6 kg. Based on the mechanical design and cable configuration of the exoskeleton, the kinematics and dynamics of driving cables were analyzed. Subsequently, a PID-based control strategy was designed with cable kinematics. To evaluate the practical performance of the proposed exoskeleton in elbow assistance, a prototype was established and experimented with six subjects. According to the experimental results, the measured elbow joint angle trajectory is generally consistent with the desired trajectory, with a mean position tracking accuracy of approximately 0.997, which supports motion stability in rehabilitation scenarios. Meanwhile, the collected sEMG values from biceps brachii and brachioradialis under the exoskeleton condition show a significant reduction in average muscle activation by 37.7% and 28.8%, respectively, compared to the condition without exoskeleton.
Passive back-support exoskeletons commonly employ elastic components to assist users during dynamic tasks. However, these designs are ineffective in providing sustained assistance for prolonged static bending postures, such as those required in surgery, assembly, and farming, where users experience continuous lumbar flexion. To address this limitation, a novel passive back-support exoskeleton inspired by the human spine is proposed in this work. The exoskeleton integrates a five-bar linkage mechanism with vertebrae-mimicking units, allowing for both dynamic flexion–extension movements and rigid support at various flexion angles. During the experiments, subjects are instructed to perform a 30-min forward-bending assembly task under two conditions: with and without wearing the exoskeleton. Compared to the free condition, the electromyography results indicate a 10.1% reduction in integrated EMG (IEMG) and a 9.78% decrease in root mean square (RMS) values of the erector spinae with the exoskeleton. Meanwhile, the metabolic rate is decreased by 11.1%, highlighting the effectiveness of the exoskeleton in mitigating muscle fatigue during prolonged static work. This work provides a promising solution for reducing musculoskeletal strain in occupations requiring sustained forward bending, making it a valuable advancement in passive exoskeleton technology.