Habiba A. Bougherara

Habiba A. Bougherara


Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 January 2022 in The International Journal of Advanced Manufacturing Technology
Verified
Journal Article
Closed access
PDF file
PNPooyan Nayyeri
Pooyan Nayyeri
Kourosh ZareiniaKourosh Zareinia
Kourosh Zareinia
Habiba A. BougheraraHabiba A. Bougherara
Habiba A. Bougherara

1 June 2018 in Composites Part A: Applied Science and Manufacturing
Verified
Journal Article
Closed access
ZMZia Mahboob
Zia Mahboob
Habiba A. BougheraraHabiba A. Bougherara
Habiba A. Bougherara

10 December 2013 in Journal of Materials Science
Verified
Journal Article
Closed access
PDF file
ISIhab El Sawi
Ihab El Sawi
ZFZouheir Fawaz
Zouheir Fawaz
ZRZitoune Redouane
Zitoune Redouane
Habiba A. BougheraraHabiba A. Bougherara
Habiba A. Bougherara

1 July 2014 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
ZBZahra S. Bagheri
Zahra S. Bagheri
ISIhab El Sawi
Ihab El Sawi
Habiba A. BougheraraHabiba A. Bougherara
Habiba A. Bougherara
RZRadovan Zdero
Radovan Zdero

1 January 2017 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
SMSaeed Manteghi
Saeed Manteghi
ZMZia Mahboob
Zia Mahboob
ZFZouheir Fawaz
Zouheir Fawaz
Habiba A. BougheraraHabiba A. Bougherara
Habiba A. Bougherara

26 June 2014 in Journal of Biomechanical Engineering
Verified
Journal Article
Closed access
PDF file
ZBZahra S. Bagheri
Zahra S. Bagheri
PAPouria Tavakkoli Avval
Pouria Tavakkoli Avval
Habiba A. BougheraraHabiba A. Bougherara
Habiba A. Bougherara
MAMina S. R. Aziz
Mina S. R. Aziz
ESEmil H. Schemitsch
Emil H. Schemitsch
RZRadovan Zdero
Radovan Zdero
Femur fracture at the tip of a total hip replacement (THR), commonly known as Vancouver B1 fracture, is mainly treated using rigid metallic bone plates which may result in “stress shielding” leading to bone resorption and implant loosening. To minimize stress shielding, a new carbon fiber (CF)/Flax/Epoxy composite plate has been developed and biomechanically compared to a standard clinical metal plate. For fatigue tests, experiments were done using six artificial femurs cyclically loaded through the femoral head in axial compression for four stages: Stage 1 (intact), stage 2 (after THR insertion), stage 3 (after plate fixation of a simulated Vancouver B1 femoral midshaft fracture gap), and stage 4 (after fracture gap healing). For fracture fixation, one group was fitted with the new CF/Flax/Epoxy plate (n = 3), whereas another group was repaired with a standard clinical metal plate (Zimmer, Warsaw, IN) (n = 3). In addition to axial stiffness measurements, infrared thermography technique was used to capture the femur and plate surface stresses during the testing. Moreover, finite element analysis (FEA) was performed to evaluate the composite plate's axial stiffness and surface stress field. Experimental results showed that the CF/Flax/Epoxy plated femur had comparable axial stiffness (fractured = 645 ± 67 N/mm; healed = 1731 ± 109 N/mm) to the metal-plated femur (fractured = 658 ± 69 N/mm; healed = 1751 ± 39 N/mm) (p = 1.00). However, the bone beneath the CF/Flax/Epoxy plate was the only area that had a significantly higher average surface stress (fractured = 2.10 ± 0.66 MPa; healed = 1.89 ± 0.39 MPa) compared to bone beneath the metal plate (fractured = 1.18 ± 0.93 MPa; healed = 0.71 ± 0.24 MPa) (p < 0.05). FEA bone surface stresses yielded peak of 13 MPa at distal epiphysis (stage 1), 16 MPa at distal epiphysis (stage 2), 85 MPa for composite and 129 MPa for metal-plated femurs at the vicinity of nearest screw just proximal to fracture (stage 3), 21 MPa for composite and 24 MPa for metal-plated femurs at the vicinity of screw farthest away distally from fracture (stage 4). These results confirm that the new CF/Flax/Epoxy material could be a potential candidate for bone fracture plate applications as it can simultaneously provide similar mechanical stiffness and lower stress shielding (i.e., higher bone stress) compared to a standard clinical metal bone plate.