Recently, multi-infeed line-commutated converter-based high-voltage direct currents (LCC-HVDCs) represent one of the most attractive ways to accommodate large-scale power transfer in main load centers. However, this approach deteriorates the dynamic var reserve (DVR) in the receiving-end power grid, especially in scenarios with heavy loads. If the system does not reserve sufficient dynamic var in advance, a severe voltage dip may occur and further lead to consecutive commutation failures, ultimately resulting in DC blocking and voltage collapse. To address the voltage/var control challenges, a robust DVR assessment method is proposed in this paper. This method is used to determine both the inductive and capacitive DVR and prevent cascading failures. First, continuous dynamic algebraic equations are formulated using a piecewise functional block approximation method for efficient application of second-order trajectory sensitivity analysis (SOTSA). Next, a robust DVR assessment model is formulated, and the corresponding computational strategy is introduced to effectively and accurately solve the large-scale problem. Finally, in numerical simulations, the computational efficiency and accuracy of the proposed method are verified using a simple system and operational data from a real system in the Eastern China Power Grid.
5 April 2022 in IEEE Transactions on Sustainable Energy
A high proportion of wind power systems with correct as set weak network connections may suffer from cascading trip faults due to the lack of conventional power plants and voltage/var support, which brings about great challenges to secure wind farm operations. To accurately and efficiently evaluate the dynamic var margin for an online field application within large-scale integrated wind areas, the transient dynamic voltage processes of hundreds or thousands of wind turbines must all be considered due to the dramatic interior voltage fluctuation effect of wind units, which brings a heavy computational burden for solving the TSCOPF problem. Therefore, to address these large-scale challenges, this paper proposes an objective-oriented approximation dimensionality reduction equivalent (OOA-DRE) approach, which accurately transforms the high-dimensional differential system to a low-dimensional system with few differential equations and low-dimensional algebraic equations for the wind unit with the maximum electrical distance value. Meanwhile, this paper uses the Levenberg-Marquardt method to obtain the global pre-evaluation error, so that the evaluation error reaches the minimum value. Finally, an actual wind power system verifies that the calculation time is reduced by approximately 2/3 compared with the original model on the premise of ensuring accuracy for large-scale systems.
The installed capacity of renewable energy has continued to increase in recent years, causing excess power to be transmitted to neighboring provinces by DC transmission with wind and thermal power bundling. However, with increasing coal cost and decreasing investment benefit of thermal power, the economic benefit of thermal power investment has decreased. Therefore, this paper proposes a method that replaces the thermal power unit with renewable energy to assume the peak regulating function of the power system. First, a novel heat storage strategy for concentrating solar power (CSP) stations is established. On this basis, the CSP station is included in the wind-thermal bundling model to replace the peak regulating function of some thermal power units, and the planning method of wind-thermal-CSP bundling with an adjustable heat storage strategy is developed. By adjusting the heat storage strategy and comparing the economic parameters under the different strategies, the optimal ratio of the installation of different powers is obtained.
Due to the high dependence of economic and social development on power systems, the demand for reliable operation of power systems is increasing. Considering the popularity and widespread installation of smart meters, accurate system/node reliability indexes can be obtained. The inverse problem of reliability evaluation (IPRE) refers to the use of known system/node reliability indexes to obtain component reliability parameters. In this paper, a novel method of solving the IPRE is proposed. First, based on a nonsequential Monte Carlo (NSMC) method, analytical expressions for system reliability indexes in terms of component reliability parameters are derived, and then, the nonlinear equations of the IPRE are constructed. Second, a high-order polynomial approximation based on the conjugate gradient algorithm is used to calculate the unknown component reliability parameters, and the results are compared with those obtained using traditional neural networks method. Finally, a continuation method is used to correct the errors of the obtained component reliability parameters. Three cases, namely, the IEEE 1979 Reliability Test System (IEEE RTS-79), the Roy Billinton Test System (RBTS) and the Chuanyu power system in Southwest China, are used to test the method proposed in this paper to verify its feasibility and accuracy.
1 January 2023 in Journal of Modern Power Systems and Clean Energy
Determining security/stability boundaries is a common and critical means of preventing cascading failures induced by voltage-related issues, which represents one of the major challenges in bulk power systems. However, traditional approaches suffer from conservative issues and heavy computational burdens. To address these challenges, the concept of an autonomous-synergic voltage security region (AS-VSR) and the corresponding dynamic constraint coefficient pruning (Deep) computation method, which fully consider the volt/var characteristics of bulk power systems, are proposed in this letter. Both linearized and nonlinearized robust optimization problems are introduced to obtain accurate results. The computational accuracy, time cost, and advantages of autonomous-synergic control are observed in the simulation results.
Power consumption forecasting is an important part of the macro planning of the industry and energy sector, and accurate forecasting of power load is very important for power grid management and power dispatching. At present, most of the power load forecasting takes the region as the object, but residents and small and medium-sized enterprise users are the basic units of electricity consumption, and their power load forecasting is as important as regional power load forecasting. compared with the regional power load, the electricity load of residents and small and medium-sized enterprises is more uncertain and more difficult to forecast. Therefore, this study combines the adaptive spectral clustering (ASC) method with the support vector quantile regression model (SVQR) to analyze the electricity consumption behavior of smart grid users and predict the residential power load. In this paper, the grid search is used to optimize the parameters of the Gaussian kernel SVQR model (GSVQR) to predict the power load, and compare it with other algorithms. From the two error evaluation index values of MAPE and pinball loss, the prediction effect of the GSVQR model is the best. In order to effectively provide uncertain information of power load, the GSVQR algorithm is used to predict the load of ultra-high energy consumption users and medium energy consumption users at any time in the future. Extensive experimental results show that: compared with other models, the prediction accuracy of the GSVQR model is higher; and the prediction results of the GSVQR model still have high reliability. Therefore, the method used in this paper can solve the problem of uncertainty of load forecasting.