The aim of this study was to investigate whether the liquid embolic agent Onyx, an ethylene vinyl alcohol copolymer, can be used to seal type 1 endoleaks during endovascular aortic repair (EVAR). Six patients with large aortic aneurysms and remaining type 1 endoleaks during or after EVAR were treated with Onyx embolization through a microcatheter placed in the proximal neck in five cases and in the distal neck in one case. Four of the patients were treated using the chimney technique. The type 1 endoleak was primarily sealed by Onyx in all six patients. There was no distal embolization. Two patients had complications during follow-up. One patient had occlusions of chimney grafts to the renal arteries and to one leg extension. These occlusions were not anatomically related to Onyx embolization. One patient had late stentgraft migration of the Onyx-treated distal neck with aneurysm rupture 18 months after treatment. Early experience of Onyx embolization as a bailout solution of type 1 endoleaks after complicated EVAR is promising. However, effective seal with Onyx does not prevent late stentgraft migration. More reported patients and longer follow-up are necessary to evaluate this new technique.
Purpose: Embolic stroke is a dreaded complication of thoracic endovascular aortic repair. The prevailing theory about its cause is that particulate debris from atherosclerotic lesions in the aortic wall are dislodged by endovascular instruments and embolize to the brain. An alternative source of embolism might be air trapped in the endograft delivery system. The aim of this experimental study was to determine whether air is released during deployment of a thoracic endograft. Methods: In an experimental benchtop study, eight thoracic endografts (five Medtronic Valiant Thoracic and three Gore TAG) were deployed in a water-filled transparent container drained from air. Endografts were prepared and deployed according to their instructions for use. Deployment was filmed and the volume of air released was collected and measured in a calibrated syringe. Results: Air was released from all the endografts examined. Air volumes ranged from 0.1 to 0.3 mL for Medtronic Valiant Thoracic and from <0.025 to 0.04 mL for Gore TAG. The largest bubbles had a diameter of approximately 3 mm and came from the proximal end of the Medtronic Valiant device. Conclusion: Air bubbles are released from thoracic endografts during deployment. Air embolism may be an alternative cause of stroke during thoracic endovascular aortic repair.
There is no established technique that directly quantifies lower limb tissue perfusion. Blood oxygenation level-dependent magnetic resonance imaging (BOLD-MRI) is an MRI technique that can determine skeletal muscle perfusion. BOLD-MRI relies on magnetic differences of oxygenated and deoxygenated hemoglobin, and regional changes in oxy/deoxyhemoglobin ratio can be recorded by T2* weighted MRI sequences. We aimed to test whether BOLD-MRI can differentiate lower limb tissue perfusion in peripheral arterial occlusive disease (PAOD) patients and healthy controls. Twenty-two PAOD patients and ten healthy elderly volunteers underwent lower limb BOLD-MRI. Reactive hyperemia was provoked by transient cuff compression and images of the gastrocnemius and soleus muscles were continuously acquired at rest, during ischemia and reperfusion. Key BOLD parameters were baseline T2* absolute value and time to T2* peak value after cuff deflation (TTP). Correlations between imaging parameters and ankle-brachial index (ABI) was investigated. The mean TTP was considerably prolonged in PAOD patients compared to healthy controls (m. gastrocnemius: 111 ± 46 versus 48 ± 22 s, p = 0.000253; m. soleus: 100 ± 42 versus 41 ± 30 s, p = 0.000216). Both gastrocnemius and soleus TTP values correlated strongly with ABI (−0.82 and −0.78, p < 0.01). BOLD-MRI during reactive hyperemia differentiated most PAOD patients from healthy controls. TTP was the most decisive parameter and strongly correlated with the ABI.
12 February 2016 in Journal of Endovascular Therapy
Purpose: To present a new endovascular technique to avoid open surgical arch reconstruction in selected patients with aneurysmal dilatation due to small chronic dissection entries in the aortic arch. Technique: The true and the false lumen of the aortic arch are catheterized from the femoral arteries. An Amplatzer Vascular Plug II (AVP II) is advanced through the proximal entry from the false lumen side and deployed as a sealing button in the entry hole, with 1 disc in the true lumen and the remaining 2 discs in the false lumen. This technique was used in 4 patients with chronic dissection involving the aortic arch, three of whom had had previous surgery for acute type A aortic dissection. In 3 patients, the false lumen of the thoracic aorta was successfully obliterated, with thrombosis and aortic diameter reduction during follow-up. In 1 patient, false lumen flow persisted, and he was subsequently treated with a total arch reconstruction and frozen elephant trunk. Conclusion: Endovascular closure of small proximal dissection entries in the aortic arch with an AVP II used as a sealing button is feasible and may be an alternative to open surgical arch reconstruction in selected patients with chronic aortic dissection and secondary aneurysm expansion.
A crucial step in image fusion for intraoperative guidance during endovascular procedures is the registration of preoperative computed tomography angiography (CTA) with intraoperative Cone Beam CT (CBCT). Automatic tools for image registration facilitate the 3D image guidance workflow. However their performance is not always satisfactory. The aim of this study is to assess the accuracy of a new fully automatic, feature-based algorithm for 3D3D registration of CTA to CBCT. The feature-based algorithm was tested on clinical image datasets from 14 patients undergoing complex endovascular aortic repair. Deviations in Euclidian distances between vascular as well as bony landmarks were measured and compared to an intensity-based, normalized mutual information algorithm. The results for the feature-based algorithm showed that the median 3D registration error between the anatomical landmarks of CBCT and CT images was less than 3 mm. The feature-based algorithm showed significantly better accuracy compared to the intensity-based algorithm (p < 0.001). A feature-based algorithm for 3D image registration is presented.