Wei Tang

Dr. Wei Tang

New Mexico State University, Klipsch School of Electrical and Computer Engineering, Mexico
orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 February 2023 in Sensors
Verified
Journal Article
Open access
PDF file
ABAmin Biglari
Amin Biglari
WTWei Tang
Wei Tang
Machine learning is an expanding field with an ever-increasing role in everyday life, with its utility in the industrial, agricultural, and medical sectors being undeniable. Recently, this utility has come in the form of machine learning implementation on embedded system devices. While there have been steady advances in the performance, memory, and power consumption of embedded devices, most machine learning algorithms still have a very high power consumption and computational demand, making the implementation of embedded machine learning somewhat difficult. However, different devices can be implemented for different applications based on their overall processing power and performance. This paper presents an overview of several different implementations of machine learning on embedded systems divided by their specific device, application, specific machine learning algorithm, and sensors. We will mainly focus on NVIDIA Jetson and Raspberry Pi devices with a few different less utilized embedded computers, as well as which of these devices were more commonly used for specific applications in different fields. We will also briefly analyze the specific ML models most commonly implemented on the devices and the specific sensors that were used to gather input from the field. All of the papers included in this review were selected using Google Scholar and published papers in the IEEExplore database. The selection criterion for these papers was the usage of embedded computing systems in either a theoretical study or practical implementation of machine learning models. The papers needed to have provided either one or, preferably, all of the following results in their studies—the overall accuracy of the models on the system, the overall power consumption of the embedded machine learning system, and the inference time of their models on the embedded system. Embedded machine learning is experiencing an explosion in both scale and scope, both due to advances in system performance and machine learning models, as well as greater affordability and accessibility of both. Improvements are noted in quality, power usage, and effectiveness.

7 May 2018 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Closed access
XTXiaochen Tang
Xiaochen Tang
QHQisong Hu
Qisong Hu
WTWei Tang
Wei Tang
This paper presents a real-time electrocardiogram (ECG) monitoring system for wearable devices. The system is based on the proposed parallel delta modulator architecture with local maximum point and local minimum point algorithms to detect QRS and PT waves. Therefore, using the proposed system and algorithm, real-time PR and RT intervals, and ST segment measurements can be achieved in long-term wearable ECG recording. The algorithm is tested with the MIT-BIH Arrhythmia Database for QRS complex detection and with the QT Database for the P and T wave detections. The simulation result shows that the algorithm achieves above 99%, 91%, and 98% accuracy in the QRS complex, P wave, and T wave detections, respectively. Experimental results are presented from the system prototype, in which the parallel delta modulator circuits are fabricated in IBM 0.13 $\rm \mu \text{m}$ standard CMOS technology and the algorithms are implemented in a Xilinx Spartan-6 field programmable gate array (FPGA). The parallel delta modulators consume 720 nW at 1 kHz sampling rate with $\rm \pm$0.6 V power supply. The proposed system has the potential to be applied in future long-term wearable ECG recording devices.

11 March 2020 in IEEE Sensors Journal
Verified
Journal Article
Closed access
QHQisong Hu
Qisong Hu
XTXiaochen Tang
Xiaochen Tang
WTWei Tang
Wei Tang
Sitting is the most common status of modern human beings. Some sitting postures may bring health issues. To prevent the harm from bad sitting postures, a local sitting posture recognition system is desired with low power consumption and low computing overhead. The system should also provide good user experience with accuracy and privacy. This paper reports a novel posture recognition system on an office chair that can categorize seven different health-related sitting postures. The system uses six flex sensors, an Analog to Digital Converter (ADC) board and a Machine Learning algorithm of a two-layer Artificial Neural Network (ANN) implemented on a Spartan-6 Field Programmable Gate Array (FPGA). The system achieves 97.78% accuracy with a floating-point evaluation and 97.43% accuracy with the 9-bit fixed-point implementation. The ADC control logic and the ANN are constructed with a maximum propagation delay of 8.714 ns. The dynamic power consumption is 7.35 mW when the sampling rate is 5 Sample/second with the clock frequency of 5 MHz.

14 May 2012 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Closed access
DKDongsoo Kim
Dongsoo Kim
BGBrian Goldstein
Brian Goldstein
WTWei Tang
Wei Tang
FSFred J. Sigworth
Fred J. Sigworth
ECEugenio Culurciello
Eugenio Culurciello
In this paper, we report on the noise analysis of low current measurement systems for biomedical applications and their fundamental limits. We analyzed resistive feedback, capacitive feedback and current amplifier circuits for low current measurement systems. Detailed noise analysis for different biomedical applications are presented and matched with measurement data using a 0.5-μm fabrication process. Based on the theoretical analysis and the corresponding measurement results, the capacitive feedback system provides better noise performance for the measurement of low current than the others. The capacitive feedback circuit is capable of measuring 750 fA RMS at a 10 kHz sampling rate, whereas the resistive feedback provides 4 pA and the current conveyor provides 600 pA at the same bandwidth. This paper provides design guidelines to maximize the performance of low current measuring system for biomedical instrumentation and to provide the best performance available with CMOS technologies.

1 July 2019 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
XTXiaochen Tang
Xiaochen Tang
ZMZiwei Ma
Ziwei Ma
QHQisong Hu
Qisong Hu
WTWei Tang
Wei Tang
Real-time wearable electrocardiogram monitoring sensor is one of the best candidates in assisting cardiovascular disease diagnosis. In this paper, we present a novel real-time machine learning system for Arrhythmia classification. The system is based on the parallel Delta modulation and QRS/PT wave detection algorithms. We propose a patient dependent rotated linear-kernel support vector machine classifier that combines the global and local classifiers, with three types of feature vectors extracted directly from the Delta modulated bit-streams. The performance of the proposed system is evaluated using the MIT-BIH Arrhythmia database. According to the AAMI standard, two binary classifications are performed and evaluated, which are supraventricular ectopic beat (SVEB) versus the rest four classes, and ventricular ectopic beat (VEB) versus the rest. For SVEB classification, the preferred SkP-32 method's F1 score, sensitivity, specificity, and positive predictivity value are 0.83, 79.3%, 99.6%, and 88.2%, respectively, and for VEB classification, the numbers are 0.92%, 92.8%, 99.4%, and 91.6%, respectively. The results show that the performance of our proposed approach is comparable to that of published research. The proposed low-complexity algorithm has the potential to be implemented as an on-sensor machine learning solution.

9 December 2020 in IEEE Sensors Journal
Verified
Journal Article
Closed access
QHQisong Hu
Qisong Hu
XTXiaochen Tang
Xiaochen Tang
WTWei Tang
Wei Tang
Sleeping is an indispensable activity of human beings. Sleeping postures have a significant effect on sleeping quality and health. A real-time low-cost sleeping posture recognition system with high privacy and good user experience is desired. In this article, we propose a sleeping posture recognition system based on a low-cost pressure sensor array which consists of conductive fabric and conductive wires. The sensor array is deployed as a bedsheet with 32 rows and 32 columns resulting in 1024 nodes. An Arduino Nano performs data collection using a 10-bit Analog to Digital Converter (ADC). The sampling rate of the overall sensor array is 0.4 frame/sec. Six health-related sleeping postures of five participants can be recognized by a shallow Convolutional Neural Network (CNN) deployed on a Personal Computer (PC). The system accuracy achieved 84.80% using the standard training-test method and 91.24% using the transfer learning-based subject-specific method. The real-time processing speed achieved 434 us/frame.