Helge Egil Seime Pettersen

Dr. Helge Egil Seime Pettersen

Haukeland University Hospital
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 October 2020 in Frontiers in Physics
Verified
Journal Article
Open access
PDF file
JAJohan Alme
Johan Alme
GBGergely Gábor Barnaföldi
Gergely Gábor Barnaföldi
RBRene Barthel
Rene Barthel
VBVyacheslav Borshchov
Vyacheslav Borshchov
TBTea Bodova
Tea Bodova
HYHiroki Yokoyama
Hiroki Yokoyama
A typical proton CT (pCT) detector comprises a tracking system, used to measure the proton position before and after the imaged object, and an energy/range detector to measure the residual proton range after crossing the object. The Bergen pCT collaboration was established to design and build a prototype pCT scanner with a high granularity digital tracking calorimeter used as both tracking and energy/range detector. In this work the conceptual design and the layout of the mechanical and electronics implementation, along with Monte Carlo simulations of the new pCT system are reported. The digital tracking calorimeter is a multilayer structure with a lateral aperture of 27 cm × 16.6 cm, made of 41 detector/absorber sandwich layers (calorimeter), with aluminum (3.5 mm) used both as absorber and carrier, and two additional layers used as tracking system (rear trackers) positioned downstream of the imaged object; no tracking upstream the object is included. The rear tracker’s structure only differs from the calorimeter layers for the carrier made of ∼200 μm carbon fleece and carbon paper (carbon-epoxy sandwich), to minimize scattering. Each sensitive layer consists of 108 ALICE pixel detector (ALPIDE) chip sensors (developed for ALICE, CERN) bonded on a polyimide flex and subsequently bonded to a larger flexible printed circuit board. Beam tests tailored to the pCT operation have been performed using high-energetic (50–220 MeV/u) proton and ion beams at the Heidelberg Ion-Beam Therapy Center (HIT) in Germany. These tests proved the ALPIDE response independent of occupancy and proportional to the particle energy deposition, making the distinction of different ion tracks possible. The read-out electronics is able to handle enough data to acquire a single 2D image in few seconds making the system fast enough to be used in a clinical environment. For the reconstructed images in the modeled Monte Carlo simulation, the water equivalent path length error is lower than 2 mm, and the relative stopping power accuracy is better than 0.4%. Thanks to its ability to detect different types of radiation and its specific design, the pCT scanner can be employed for additional online applications during the treatment, such as in-situ proton range verification.

1 November 2021 in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
Verified
Journal Article
Open access
GEGrete May Engeseth
Grete May Engeseth
RHRenjie He
Renjie He
DMDragan Mirkovic
Dragan Mirkovic
PYPablo Yepes
Pablo Yepes
Abdallah Sherif Radwan MohamedAbdallah Sherif Radwan Mohamed
Abdallah Sherif Radwan Mohamed
GGGary Brandon Gunn
Gary Brandon Gunn
Intensity modulated proton therapy (IMPT) could yield high linear energy transfer (LET) in critical structures and increased biological effect. For head and neck cancers at the skull base this could potentially result in radiation-associated brain image change (RAIC). The purpose of the current study was to investigate voxel-wise dose and LET correlations with RAIC after IMPT. For 15 patients with RAIC after IMPT, contrast enhancement observed on T1-weighted magnetic resonance imaging was contoured and coregistered to the planning computed tomography. Monte Carlo calculated dose and dose-averaged LET (LETd) distributions were extracted at voxel level and associations with RAIC were modelled using uni- and multivariate mixed effect logistic regression. Model performance was evaluated using the area under the receiver operating characteristic curve and precision-recall curve. An overall statistically significant RAIC association with dose and LETd was found in both the uni- and multivariate analysis. Patient heterogeneity was considerable, with standard deviation of the random effects of 1.81 (1.30-2.72) for dose and 2.68 (1.93-4.93) for LETd, respectively. Area under the receiver operating characteristic curve was 0.93 and 0.95 for the univariate dose-response model and multivariate model, respectively. Analysis of the LETd effect demonstrated increased risk of RAIC with increasing LETd for the majority of patients. Estimated probability of RAIC with LETd = 1 keV/µm was 4% (95% confidence interval, 0%, 0.44%) and 29% (95% confidence interval, 0.01%, 0.92%) for 60 and 70 Gy, respectively. The TD15 were estimated to be 63.6 and 50.1 Gy with LETd equal to 2 and 5 keV/µm, respectively. Our results suggest that the LETd effect could be of clinical significance for some patients; LETd assessment in clinical treatment plans should therefore be taken into consideration.

1 July 2017 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
Helge Egil Seime PettersenHelge Egil Seime Pettersen
Helge Egil Seime Pettersen
JAJ. Alme
J. Alme
ABA. Biegun
A. Biegun
ABA. van Den Brink
A. van Den Brink
MCM. Chaar
M. Chaar
DRD. Röhrich
D. Röhrich

1 November 2019 in Radiotherapy and Oncology
Verified
Journal Article
Closed access
JDJon Espen Dale
Jon Espen Dale
SMSilvia Molinelli
Silvia Molinelli
VVViviana Vitolo
Viviana Vitolo
BVBarbara Vischioni
Barbara Vischioni
MBMaria Bonora
Maria Bonora
PFPiero Fossati
Piero Fossati

1 July 2019 in Physica Medica
Verified
Journal Article
Closed access
Helge Egil Seime PettersenHelge Egil Seime Pettersen
Helge Egil Seime Pettersen
JAJohan Alme
Johan Alme
GBGergely Gábor Barnaföldi
Gergely Gábor Barnaföldi
RBRene Barthel
Rene Barthel
ABAnthony van Den Brink
Anthony van Den Brink
DRDieter Röhrich
Dieter Röhrich

31 July 2019 in Acta Oncologica
Verified
Journal Article
Closed access
CSCamilla H. Stokkevåg
Camilla H. Stokkevåg
DIDaniel J. Indelicato
Daniel J. Indelicato
KHKlaus Herfarth
Klaus Herfarth
HMHenriette Magelssen
Henriette Magelssen
MEMorten E. Evensen
Morten E. Evensen
LMLudvig P. Muren
Ludvig P. Muren
Background: Children with brain tumors undergoing radiotherapy are at particular risk of radiation-induced morbidity and are therefore routinely considered for proton therapy (PT) to reduce the dose to healthy tissues. The aim of this study was to apply pediatric constraints and normal tissue complication probability (NTCP) models when evaluating the differences between PT and contemporary photon-based radiotherapy, volumetric modulated arc therapy (VMAT). Methods: Forty patients (aged 1-17 years) referred from Norwegian institutions to cranial PT abroad during 2014-2016 were selected for VMAT re-planning using the original CT sets and target volumes. The VMAT and delivered PT plans were compared by dose/volume metrics and NTCP models related to growth hormone deficiency, auditory toxicity, visual impairment, xerostomia, neurocognitive outcome and secondary brain and parotid gland cancers. Results: The supratentorial brain, temporal lobes, hippocampi, hypothalamus, pituitary glands, cochleas, salivary glands, optic nerves and chiasm received lower mean doses from PT. Reductions in population median NTCP were significant for auditory toxicity (VMAT: 3.8%; PT: 0.3%), neurocognitive outcome (VMAT: 3.0 IQ points decline at 5 years post RT; PT: 2.5 IQ points), xerostomia (VMAT: 2.0%; PT: 0.6%), excess absolute risk of secondary cancer of the brain (VMAT: 9.2%; PT: 6.7%) and salivary glands (VMAT: 2.8%; PT:0.5%). Across all patients, 23/38 PT plans had better or comparable estimated risks for all endpoints (within ±10% of the risk relative to VMAT), whereas for 1/38 patients all estimates were better or comparable with VMAT. Conclusions: PT reduced the volumes of normal tissues exposed to radiation, particularly low-to-intermediate dose levels, and this was reflected in lower NTCP. Of the included endpoints, substantial reductions in population medians were seen from the delivered PT plans for auditory complications, xerostomia, and risk of secondary cancers of the brain and salivary glands.