Leopoldo Altamirano-Robles

Dr. Leopoldo Altamirano-Robles

Computational Sciences, National Institute of Astrophysics, Optics and Electronics, Puebla City, Mexico
orcid

Research Focus & Metrics

Academic Career Length

32Years (1995-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2012 in Artificial Intelligence in Medicine
Verified
Journal Article
Closed access
HEHugo Jair Escalante
Hugo Jair Escalante
MMManuel Montes-y-Gómez
Manuel Montes-y-Gómez
JGJesús A. González
Jesús A. González
PGPilar Gómez Gil
Pilar Gómez Gil
LALeopoldo Altamirano-Robles
Leopoldo Altamirano-Robles
ARAlejandro Rosales
Alejandro Rosales

24 June 2015 in PLOS ONE
Verified
Journal Article
Open access
PDF file
CRCarolina Reta
Carolina Reta
LALeopoldo Altamirano-Robles
Leopoldo Altamirano-Robles
JGJesus A. Gonzalez
Jesus A. Gonzalez
RDRaquel Díaz-Hernández
Raquel Díaz-Hernández
HPHayde Peregrina
Hayde Peregrina
RLRuben Lobato
Ruben Lobato
Morphological identification of acute leukemia is a powerful tool used by hematologists to determine the family of such a disease. In some cases, experienced physicians are even able to determine the leukemia subtype of the sample. However, the identification process may have error rates up to 40% (when classifying acute leukemia subtypes) depending on the physician’s experience and the sample quality. This problem raises the need to create automatic tools that provide hematologists with a second opinion during the classification process. Our research presents a contextual analysis methodology for the detection of acute leukemia subtypes from bone marrow cells images. We propose a cells separation algorithm to break up overlapped regions. In this phase, we achieved an average accuracy of 95% in the evaluation of the segmentation process. In a second phase, we extract descriptive features to the nucleus and cytoplasm obtained in the segmentation phase in order to classify leukemia families and subtypes. We finally created a decision algorithm that provides an automatic diagnosis for a patient. In our experiments, we achieved an overall accuracy of 92% in the supervised classification of acute leukemia families, 84% for the lymphoblastic subtypes, and 92% for the myeloblastic subtypes. Finally, we achieved accuracies of 95% in the diagnosis of leukemia families and 90% in the diagnosis of leukemia subtypes.

1 March 2017 in Infrared Physics & Technology
Verified
Journal Article
Closed access
DHD. Hernandez-Contreras
D. Hernandez-Contreras
HPHayde Peregrina-Barreto
Hayde Peregrina-Barreto
Jose Rangel-MagdalenoJose Rangel-Magdaleno
Jose Rangel-Magdaleno
JGJ.A. Gonzalez-Bernal
J.A. Gonzalez-Bernal
LALeopoldo Altamirano-Robles
Leopoldo Altamirano-Robles

31 December 2024 in Sensors
Verified
Journal Article
Open access
PDF file
HAHector Anaya-Sanchez
Hector Anaya-Sanchez
LALeopoldo Altamirano-Robles
Leopoldo Altamirano-Robles
RDRaquel Díaz-Hernández
Raquel Díaz-Hernández
Saúl Zapotecas-MartínezSaúl Zapotecas-Martínez
Saúl Zapotecas-Martínez
Accurate synthetic image generation is crucial for addressing data scarcity challenges in medical image classification tasks, particularly in sensor-derived medical imaging. In this work, we propose a novel method using a Wasserstein Generative Adversarial Network with Gradient Penalty (WGAN-GP) and nearest-neighbor interpolation to generate high-quality synthetic images for diabetic retinopathy classification. Our approach enhances training datasets by generating realistic retinal images that retain critical pathological features. We evaluated the method across multiple retinal image datasets, including Retinal-Lesions, Fine-Grained Annotated Diabetic Retinopathy (FGADR), Indian Diabetic Retinopathy Image Dataset (IDRiD), and the Kaggle Diabetic Retinopathy dataset. The proposed method outperformed traditional generative models, such as conditional GANs and PathoGAN, achieving the best performance on key metrics: a Fréchet Inception Distance (FID) of 15.21, a Mean Squared Error (MSE) of 0.002025, and a Structural Similarity Index (SSIM) of 0.89 in the Kaggle dataset. Additionally, expert evaluations revealed that only 56.66% of synthetic images could be distinguished from real ones, demonstrating the high fidelity and clinical relevance of the generated data. These results highlight the effectiveness of our approach in improving medical image classification by generating realistic and diverse synthetic datasets.

1 February 2003 in Micron
Verified
Journal Article
Closed access
AFA.B Flores
A.B Flores
LALeopoldo Altamirano-Robles
Leopoldo Altamirano-Robles
MAM.O Arias
M.O Arias
JAJ.A Ascencio
J.A Ascencio

24 July 2015 in PLOS ONE
Verified
Journal Article
Open access
PDF file
CRCarolina Reta
Carolina Reta
LALeopoldo Altamirano-Robles
Leopoldo Altamirano-Robles
JGJesus A. Gonzalez
Jesus A. Gonzalez
RDRaquel Díaz-Hernández
Raquel Díaz-Hernández
HPHayde Peregrina
Hayde Peregrina
RLRuben Lobato
Ruben Lobato