Naoki Asakawa

Prof. Dr. Naoki Asakawa

Graduate School of Science and Technology, Gunma University, 1-5-1 Tenjincho, Kiryu, Gunma 376-8515, Japan

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 July 2024 in Journal of Ethnopharmacology
Verified
Journal Article
Closed access
SGSumin Ge
Sumin Ge
SWSihua Wu
Sihua Wu
QYQin Yin
Qin Yin
MTMeng Tan
Meng Tan
SWSichuan Wang
Sichuan Wang
XPxin pan
xin pan

1 April 2024 in Review of Scientific Instruments
Verified
Journal Article
Open access
PDF file
NKNatsuki Kawabata
Natsuki Kawabata
Naoki AsakawaNaoki Asakawa
Naoki Asakawa
A new technique for ex situ solid-state nuclear magnetic resonance imaging of polymeric films has been developed. This method uses the static magnetic field gradient generated by a water-cooled copper electromagnet. The imaging process involves scanning the sample in the plane of the film under a static magnetic field gradient. Two-dimensional (2D) 19F MRI measurements are attempted, where the fast Fourier transform (FFT) spectra of the second half of a Hahn echo peak is used for the depth (X-axis) direction, and the sample film is mechanically moved for the Y-axis, which is in-plane with respect to the film surface and normal to the inter-magnetic-pole line (Z-axis). The sample is a poly(tetrafluoroethylene) [PTFE] film with carved stripes on its surface. Furthermore, three-dimensional (3D) measurements of the film surface and thickness orientations were also performed for an analogous PTFE film. For 2D profiling on the film surface, 2D sample-moving was used. For depth profiling, FFT spectrum analysis was undertaken for each voxel situated at a specific (Y, Z) coordinate within the film. As a result, a 3D image of the sample and its corresponding geometry were obtained, although the scanning area was restricted to a part of the sample. Finally, numerical simulations of the spatial distribution of the static magnetic field were performed to confirm the validity of the present method.

18 November 2024 in Physical Review E
Verified
Journal Article
Closed access
NKNatsuki Kawabata
Natsuki Kawabata
Naoki AsakawaNaoki Asakawa
Naoki Asakawa
TKTeruo Kanki
Teruo Kanki
An ex-situ solid-state nuclear magnetic resonance (NMR) method employing localized magnetic field gradients generated by a needlelike ferromagnet is described. The depth profiling of a multilayer polymeric film using the proposed method and spin density imaging is successfully acquired. The imaging of the variable-frequency spinlattice relaxation rate in the depth direction reveals differences in the spectral density function for molecular dynamics between the surface and interior of the film. This may be due to the differences in the correlation time distribution of the molecular dynamics between the surfaces and interior of the film.

15 February 2022 in Polymers
Verified
Journal Article
Open access
PDF file
YSYoshiharu Suzuki
Yoshiharu Suzuki
Naoki AsakawaNaoki Asakawa
Naoki Asakawa
Stochastic Resonance (SR) is a phenomenon in which noise improves the performance of a system. With the addition of noise, a weak input signal to a nonlinear system, which may exceed its threshold, is transformed into an output signal. In the other words, noise-driven signal transfer is achieved. SR has been observed in nonlinear response systems, such as biological and artificial systems, and this review will focus mainly on examples of previous studies of mathematical models and experimental realization of SR using poly(hexylthiophene)-based organic field-effect transistors (OFETs). This phenomenon may contribute to signal processing with low energy consumption. However, the generation of SR requires a noise source. Therefore, the focus is on OFETs using materials such as organic materials with unstable electrical properties and critical elements due to unidirectional signal transmission, such as neural synapses. It has been reported that SR can be observed in OFETs by application of external noise. However, SR does not occur under conditions where the input signal exceeds the OFET threshold without external noise. Here, we present an example of a study that analyzes the behavior of SR in OFET systems and explain how SR can be made observable. At the same time, the role of internal noise in OFETs will be explained.

26 January 2018 in Physical Review E
Verified
Journal Article
Closed access
PDF file
YSYoshiharu Suzuki
Yoshiharu Suzuki
Naoki AsakawaNaoki Asakawa
Naoki Asakawa
The application of noise to a nonlinear system can have the effect of increasing the signal transmission of the system through the phenomenon of stochastic resonance (SR). This paper presents an analytical characterization of the dependence of the signal transmission performance of an organic field-effect transistor (OFET) on external noise. Similarly to the threshold of a nonlinear system, the additive internal noise of the system can be used to control the emergence of SR. Internal noise or the addition of random numbers to the system enables one to observe the SR phenomenon in an OFET under an intrinsically nonresonant condition. Internal noise plays a thresholdlike role, but it functions in a different manner. The fluctuations in performance due to external noise become smaller when the effect of internal noise becomes dominant compared with that of the threshold. In conclusion, it is found that internal noise plays a robust thresholdlike role with respect to variations in external noise intensity.

14 August 2017 in Frontiers in Materials
Verified
Journal Article
Open access
KFKunito Fukuda
Kunito Fukuda
Naoki AsakawaNaoki Asakawa
Naoki Asakawa
Spin-dependent space-charge-limited carrier conduction in a Schottky barrier diode using polycrystalline p-type π-conjugated molecular pentacene is explored using multiple-frequency electrically detected magnetic resonance (EDMR) spectroscopy with a variable-angle configuration. The measured EDMR spectra are decomposed into two components derived, respectively, from mobile and trapped positive polarons. The linewidth of the EDMR signal for the trapped polarons increases with increasing resonance magnetic field for an in-plane configuration where the normal vector of the device substrate is perpendicular to the resonance magnetic field, while it is independent of the field for an out-of-plane configuration. This difference is consistent with the pentacene arrangement on the device substrate, where pentacene molecules exhibit a uniaxial orientation on the out-of-substrate plane. By contrast, the mobile polarons do not show anisotropic behavior with respect to the resonance magnetic field, indicating that the anisotropic effect is averaged out owing to carrier motion. These results suggest that the orientational arrangements of polycrystalline pentacene molecules in a nano thin film play a crucial role in spin-dependent electrical conduction.