This paper develops a life cycle assessment framework for embodied environmental impacts of building construction systems. The framework is intended to be used early in the design stage to assist decision making in identifying sources of higher embodied impacts and in selecting sustainable design alternatives. The framework covers commonly used building construction systems such as reinforced concrete construction (RCC), hot-rolled steel construction (HRS), and light steel construction (LSC). The system boundary is defined for the framework from cradle-to-grave plus recycling and reuse possibilities. Building Information Modeling (BIM) and life cycle assessment are integrated in the developed framework to evaluate life cycle embodied energy and embodied greenhouse emissions of design options. The life cycle inventory data used to develop the framework were extracted from BIM models for the building material quantities, verified Environmental Product Declarations (EPD) for the material production stage, and the design of construction operations for the construction and end-of-life stages. Application of the developed framework to a case study of a university building revealed the following results. The material production stage had the highest contribution to embodied impacts, reaching about 90%. Compared with the conventional RCC construction system, the HRS construction system had 41% more life cycle embodied energy, while the LSC construction system had 34% less life cycle embodied energy. When each system was credited with the net benefits resulting from possible recycling/reuse beyond building life, the HRS construction system had 10% less life cycle embodied energy, while the LSC construction system had 68% less life cycle embodied energy. Similarly, the HRS construction system had 29% less life cycle greenhouse gas (GHG) emissions, while the LSC construction system had 62% less life cycle GHG emissions. Sustainability assessment results showed that the RCC construction system received zero Leadership in Energy and Environmental Design (LEED) credit points, the HRS construction system received three LEED credit points, while the LSC construction system received five LEED credit points.
26 February 2019 in Advances in Structural Engineering
This article presents an experimental study on the screw connections between cold-formed steel walls and cement-based boards such as fibercement boards and ferrocement boards. The effect of loading direction, type of sheathing, board thickness, and screw number and spacing were investigated. Tests were performed under shear which is perpendicular to the free edge and also under shear which is parallel to the free edge of the board to simulate the actual behavior of sheathed shear walls. In each case, the peak load and displacement, elastic load and displacement, elastic stiffness and ductility were found and compared to other cases. The results of the 20 test reported in the paper showed that connection strength obtained under parallel loading was much higher than those obtained under perpendicular loading while as the displacements obtained under parallel loading were much larger than those obtained under perpendicular loading. Consequently, the elastic stiffness values were found to be smaller under parallel loading than under perpendicular loading. The results also showed that fibercement boards had much higher strength than ferrocement board, and that the screw strength increased nearly linearly with the board thickness.
The objective of this paper is to apply the life cycle assessment methodology to assess the environmental impacts of light steel framed buildings fabricated from cold formed steel (CFS) sections. The assessment covers all phases over the life span of the building from material production, construction, use, and the end of building life, in addition to loads and benefits from reuse/recycling after building disposal. The life cycle inventory and environmental impact indicators are estimated using the Athena Impact Estimator for Buildings. The input data related to the building materials used are extracted from a building information model of the building while the operating energy in the use phase is calculated using an energy simulation software. The Athena Impact Estimator calculates the following mid-point environmental measures: global warming potential (GWP), acidification potential, human health potential, ozone depletion potential, smog potential, eutrophication potential, primary and non-renewable energy (PE) consumption, and fossil fuel consumption. The LCA assessment was applied to a case study of a university building. Results of the case study related to GWP and PE were as follows. The building foundations were responsible for 29% of the embodied GWP and 20% of the embodied PE, while the CFS skeleton was responsible for 30% of the embodied GWP and 49% of the embodied PE. The production stage was responsible for 90% of the embodied GWP and embodied PE. When benefits associated with recycling/reuse were included in the analysis according to Module D of EN 15978, the embodied GWP was reduced by 15.4% while the embodied PE was reduced by 6.22%. Compared with conventional construction systems, the CFS framing systems had much lower embodied GWP and PE.
This paper represents the finite element results for the local buckling of tapered plate girders subjected to combine pure bending and shear stresses. An idealized model is developed representing the loading of the tapered panel that generates uniform normal stresses due to flexure, or uniform and constant shear stresses in the case of shear. Eigen-value analysis was performed for several tapered web plate girders that have different geometric parameters. A parametric study is made to reduce the FE model size showing the effect of decreasing the tapered panel adjacent straight panels, maintaining the same result accuracy as a complete girder model. The combined buckling capacity of bending and shear is determined by applying all possible load pattern combinations, together with different interaction ratios. An analysis study is presented to investigate the effect of the tapering angle on the combined bending–shear capacity of the girder. The study also includes the effect of the flange and web slenderness on the local buckling of the girder. Considering residual stresses as part of the loading stresses, the analysis procedure is repeated for some cases, and the effect of combining of the residual stresses together with the external loads is found. Empirical approximate formulae are given to estimate the combined flexure–shear buckling resistance of the tapered girder safely