Fang Liu

Dr. Fang Liu

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 January 2024 in Sensors
Verified
Journal Article
Open access
PDF file
LZLi Zhangwen
Li Zhangwen
JCJinxing Cheng
Jinxing Cheng
FLFang Liu
Fang Liu
WQWang Qingbo
Wang Qingbo
WWWei-Wei Wen
Wei-Wei Wen
ZWZeqian Wu
Zeqian Wu
CdZnTe (CZT) is a new type of compound semiconductor that has emerged in recent years. Compared to other semiconductor materials, it possesses an ideal bandgap, high density, and high electron mobility, rendering it an excellent room-temperature composite semiconductor material for X-ray and γ-ray detectors. Due to the exceptional performance of CZT material, detectors manufactured using it exhibit high energy resolution, spatial resolution, and detection efficiency. They also have the advantage of operating at room temperature. CZT array detectors, furthermore, demonstrate outstanding spatial detection and three-dimensional imaging capabilities. Researchers worldwide have conducted extensive studies on this subject. This paper, building upon this foundation, provides a comprehensive analysis of CZT crystals and CZT array detectors and summarizes existing research to offer valuable insights for envisioning new detector methodologies.

13 August 2024 in International Journal of Hydrogen Energy
Verified
Journal Article
Closed access
LWLin Wang
Lin Wang
XLXuefeng Lyu
Xuefeng Lyu
JZJiayu Zhang
Jiayu Zhang
FLFang Liu
Fang Liu
XLXiangbin Li
Xiangbin Li
TMTie Ma
Tie Ma

31 January 2022 in Sensors
Verified
Journal Article
Open access
PDF file
FLFang Liu
Fang Liu
XFXiaoxue Fan
Xiaoxue Fan
XSXilei Sun
Xilei Sun
Bin LiuBin Liu
Bin Liu
JLJunjie Li
Junjie Li
PYPeiguang Yan
Peiguang Yan
Silicon Photomultiplier (SiPM) is a sensor that can detect low-light signals lower than the single-photon level. In order to study the properties of neutrinos at a low detection threshold and low radioactivity experimental background, a low-temperature CsI neutrino coherent scattering detector is designed to be read by the SiPM sensor. Less thermal noise of SiPM and more light yield of CsI crystals can be obtained at the working temperature of liquid nitrogen. The breakdown voltage (Vbd) and dark count rate (DCR) of SiPM at liquid nitrogen temperature are two key parameters for coherent scattering detection. In this paper, a low-temperature test is conducted on the mass-produced ON Semiconductor J-Series SiPM. We design a cryogenic system for cooling SiPM at liquid nitrogen temperature and the changes of operating voltage and dark noise from room to liquid nitrogen temperature are measured in detail. The results show that SiPM works at the liquid nitrogen temperature, and the dark count rate drops by six orders of magnitude from room temperature (120 kHz/mm2) to liquid nitrogen temperature (0.1 Hz/mm2).

1 January 2023 in Acta Physica Sinica
Verified
Journal Article
Closed access
PDF file
JZJian-Ming Zhang
Jian-Ming Zhang
ZLZhi-Wei Li
Zhi-Wei Li
FLFang Liu
Fang Liu
JLJing-Tai Li
Jing-Tai Li
XMXin Mao
Xin Mao
RHRan Han
Ran Han
The muon transmission imaging method is a non-destructive detection imaging method and can obtain the internal density structure of the target object by analyzing the flux change of cosmic ray muon before and after passing through the target object. This method assumes that muon travels along a straight line in a lowatomic number material. However, the multiple Coulomb scattering causes the muon deviate from the straight line to a certain extent when penetrating the material, which may have a certain influence on the accuracy of muon transmission imaging. This study uses the Geant4 software package to carry out Monte Carlo simulation of muon transmission imaging. Object models with multiple density structures and several meters are used to analyze the effect of multiple scattering on the accuracy of transmission imaging. In the experiment, we set up a model in which muons of different energy vertically pass through a rock with a certain thickness, we can intuitively see the influence of scattering on the penetration path of muons. By setting up rock-water block models with thickness in a range of 0.8, 2.4 and 4.0 m, the effect of Coulomb scattering on the transmission imaging of small-scale material muons is analyzed. The results suggest that the muon transmission imaging method can well restore the geometric shape and spatial distribution characteristics of density anomalies for objects with several-meter scale for standard rock materials with a scale of several meters. However, the flux deviation caused by multiple Coulomb scattering on the muons in the near-vertical direction can reach 5%, and up to 13% in the boundary areas of the standard rock and air. We limit the scattering angle of the muon, and select the muon with a scattering angle of less than or equal to 1° for imaging. The results of transmission imaging by using the selected muon have improved. The image does not have the illusion of an abnormally increased flux around the model caused by scattering, but the muon flux in the model area is reduced even more, thereby affecting the accuracy of restoring the absolute density of an object using flux differences. Therefore, the effects of multiple Coulomb scattering should be considered for recovering more accurate absolute density in small-scale muon transmission imaging study.

20 November 2023 in Scientific Reports
Verified
Journal Article
Open access
PDF file
XYXin Yuan
Xin Yuan
FLFang Liu
Fang Liu
HZHongchi Zhou
Hongchi Zhou
Bin LiuBin Liu
Bin Liu
GLGuanda Li
Guanda Li
FNFenglei Niu
Fenglei Niu
Gamma radiation is progressively emerging as an effective method to enhance the sterilization efficiency of medical plastics including Polyvinyl chloride (PVC). The parameters of the radiation facility will affect the efficiency of radiation sterilization. To investigate these effects, we simulate the gamma radiation sterilization performance of PVC material sample using Monte Carlo Method. The simulation results indicated that compared with the sterilization time of 20–90 min from high-temperature steam sterilization of medical waste, by optimizing the parameters of the model radiation facility, the radiation sterilization time can be reduced to 6.61 min. The optimized model facility parameters are as follows: the gamma photon energy is 1.25 MeV, the model space is 300 × 300 × 300 cm3, the reflective layer material is concrete and its thickness is 8 cm, the PVC sample layer area is 100 × 100 cm2, the distance between the radiation source and the PVC sample layer is 150 cm, the energy deposition in the bottom layer of the PVC sample layer is 1.31315 × 10–6 MeV/g. This study offers a potentially feasible way for PVC sterilization, while also providing a crucial reference for the further promotion and application of radiation sterilization technology.

9 December 2021 in Life
Verified
Journal Article
Open access
PDF file
FLFang Liu
Fang Liu
ZZZhengtong Zhong
Zhengtong Zhong
Bin LiuBin Liu
Bin Liu
TJTianze Jiang
Tianze Jiang
HZHongchi Zhou
Hongchi Zhou
XOXiao-ping Ouyang
Xiao-ping Ouyang
The SARS-CoV-2 virus is deadly, contagious, can cause COVID-19 disease, and endangers public health and safety. The development of SARS-CoV-2 inactivation technology is crucial and imminent in current pandemic period. Neutron radiation is usually used to sterilize viruses because neutron radiation is 10 times more effective than gamma-rays in inactivating viruses. In this work we established a closed SARS-CoV-2 inactivation container model by the Monte Carlo method and simulated the inactivation performance by using several different neutrons sources. To study the effects of inactivation container factors, including the reflector thickness, the type of the reflector material, the SARS-CoV-2 layer area and the distance from the radiation source on the energy deposition of a single neutron particle in SARS-CoV-2 sample, we simulated the neutron energy deposition on a SARS-CoV-2 sample. The simulation results indicate that the saturated thicknesses of reflector materials for graphite, water and paraffin are approximately 30 cm, 15 cm, and 10 cm, respectively, and the energy deposition (radiation dose) becomes larger when the SARS-CoV-2 layer area is smaller and the SARS-CoV-2 layer is placed closer to the neutron source. The calculated single-neutron energy deposition on 10 × 10 cm2 SARS-CoV-2 layer is about 3.0059 × 10−4 MeV/g with graphite as the reflection layer, when the 14 MeV neutron source intensity is 1012 n/s and the SARS-CoV-2 layer is 5 cm away from the neutron source. If the lethal dose of SARS-CoV-2 is assumed as the IAEA recommended reference dose, 25 kGy, the SARS-CoV-2 could be decontaminated in about 87 min, and the sterilization time could be less than 52 s if the 14 MeV neutron intensity is increased to 1014 n/s.