7 August 2009 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
CLChien-Hung Liu
Chien-Hung Liu
Yuan-Yih HsuYuan-Yih Hsu
Yuan-Yih Hsu
A self-tuning proportional-integral (PI) controller in which the controller gains are adapted using the particle swarm optimization (PSO) technique is proposed for a static synchronous compensator (STATCOM). An efficient formula for the estimation of system load impedance using real-time measurements is derived. Based on the estimated system load, a PSO algorithm, which takes the best particle gains, the best global gains, and previous change of gains into account, is employed to reach the desired controller gains. To demonstrate the effectiveness of the proposed PSO self-tuning PI controller for a STATCOM, experimental results for a system under different loading conditions are presented. Results from the self-tuning PI controller are compared with those from the fixed-gain PI controllers.

1 May 1997 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
FLFeng-Chang Lu
Feng-Chang Lu
Yuan-Yih HsuYuan-Yih Hsu
Yuan-Yih Hsu
A fuzzy dynamic programming (FDP) approach is proposed for solving the reactive power/voltage control problem in a distribution substation. The main purpose is to improve the voltage profile on the secondary bus and restrain the reactive power flow into a main transformer at the same time. To reach our objectives, the load tap changer (LTC) usually installed in a main transformer is employed to adjust the secondary voltage and the capacitor connected to the secondary bus is employed to compensate the reactive power flow for the load demands. We first forecast the real and reactive power demands of a main transformer and its primary voltages for the next day. With these forecasting data at hand, a fast LTC tap position estimation formula that takes the load models into account is derived to effectively reduce the computational burden for the proposed approach. Practical constraints on bus voltage limits, maximum allowable number switching operations in a day for the LTC and capacitor and the tolerable worst power factor for a main transformer are also considered. To demonstrate the usefulness of the proposed approach, reactive power/voltage control at a distribution substation within the service area of Taipei City District Office of Taiwan Power Company is investigated. It is found that a proper dispatching schedule for the LTC and capacitor can be reached by the proposed approach.

1 January 1998 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
Yuan-Yih HsuYuan-Yih Hsu
Yuan-Yih Hsu
FLFeng-Chang Lu
Feng-Chang Lu

31 January 2008 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
BCBen-Sheng Chen
Ben-Sheng Chen
Yuan-Yih HsuYuan-Yih Hsu
Yuan-Yih Hsu
In this paper, a novel controller with fixed modulation index (MI) and variable dc capacitor voltage reference to minimize voltage and current harmonics is presented for a distribution static synchronous compensator (STATCOM). The STATCOM with the proposed controller consists of a three-phase voltage-sourced inverter and a dc capacitor and is used to provide reactive power compensation and regulate ac system bus voltage with minimum harmonics. A systematic design procedure based on pole-zero cancellation, root locus method, and pole assignment method has been developed to determine proper parameters for the current regulator, the dc voltage controller, and the ac voltage controller of the STATCOM. With the proposed STATCOM controller, harmonic distortions in the inverter output current and voltage can be reduced since the MI is held constant at unity in steady state. In addition, a fast adjustment in the STATCOM output reactive power is achieved to regulate the ac bus voltage through the adjustment of the dc voltage reference during the transient period. Simulation and experimental results for the steady-state operating condition and transient operating conditions for the system subjected to a reactive current reference step change, a three-phase line to neutral fault, and a step load change are presented to demonstrate the effectiveness of the proposed controller.

8 February 2010 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
CLChien-Hung Liu
Chien-Hung Liu
Yuan-Yih HsuYuan-Yih Hsu
Yuan-Yih Hsu
The effect of rotor excitation voltage on steady-state stability and output power of a doubly fed induction generator (DFIG) is investigated. Wind turbine mechanical torque-speed characteristics, as well as generator electromagnetic torque-speed characteristics, are considered in the derivation of the steady-state stability region for the magnitude and phase angle of the rotor excitation voltage. To evaluate the maximum output power of a DFIG, detailed expressions for stator power, rotor power, stator loss, rotor loss, and electrical power are derived as functions of the generator speed and the magnitude and phase angle of the rotor excitation voltage. The effect of stator resistance on the magnitude and phase angle of the resultant optimal rotor excitation voltage, which gives maximum output power and minimum loss, is examined. Experimental results are given to demonstrate the effectiveness of the theoretical analysis.

1 May 2015 in IET Renewable Power Generation
Verified
Journal Article
Open access
PDF file
YWYung‐Tsai Weng
Yung‐Tsai Weng
Yuan-Yih HsuYuan-Yih Hsu
Yuan-Yih Hsu
Maximum power tracking and copper loss minimisation of a doubly fed induction generator (DFIG) can be achieved through the control of rotor currents. In this study, a sliding mode regulator (SMR) is presented to regulate the rotor current of a DFIG. The purpose of the SMR is to regulate the rotor current to the target commands of maximum power tracking and copper loss minimisation with stator flux orientation. The robustness to parameter variations can be accomplished by the proposed SMR when the wind turbine is subject to changing wind speed. Simulation results of the DFIG system on a 2.5 MW generator are provided and compared with a fixed‐gain proportional–integral (PI) regulator. It is observed from the simulation results that the dynamic responses achieved by the proposed SMR are more robust than those by the fixed‐gain PI regulator. The chattering effect caused by the switching function of the SMR can be reduced by an integral type SMR.