Karina Wierzbowska-Drabik

Dr. Karina Wierzbowska-Drabik

orcid

Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 August 2021 in European Heart Journal
Verified
Journal Article
Open access
PDF file
QCQuirino Ciampi
Quirino Ciampi
AZAngela Zagatina
Angela Zagatina
LCLauro Cortigiani
Lauro Cortigiani
KWKarina Wierzbowska-Drabik
Karina Wierzbowska-Drabik
Jaroslaw Damian KasprzakJaroslaw Damian Kasprzak
Jaroslaw Damian Kasprzak
EPEugenio Picano
Eugenio Picano
The aim of this study was to assess the prognostic value of ABCDE-SE in a prospective, large scale, multicentre, international, effectiveness study. Stress echocardiography (SE) was recently upgraded to the ABCDE protocol: step A, regional wall motion abnormalities; step B, B lines; step C, left ventricular contractile reserve; step D, Doppler-based coronary flow velocity reserve in left anterior descending coronary artery; and step E, electrocardiogram-based heart rate reserve. From July 2016 to November 2020, we enrolled 3574 all-comers (age 65 ± 11 years, 2070 males, 58%; ejection fraction 60 ± 10%) with known or suspected chronic coronary syndromes referred from 13 certified laboratories. All patients underwent clinically indicated ABCDE-SE. The employed stress modality was exercise (n = 952, with semi-supine bike, n = 887, or treadmill, n = 65 with adenosine for step D) or pharmacological stress (n = 2622, with vasodilator, n = 2151; or dobutamine, n = 471). SE response ranged from score 0 (all steps normal) to score 5 (all steps abnormal). All-cause death was the only endpoint. Rate of abnormal results was 16% for A, 30% for B, 36% for C, 28% for D, and 37% for E steps. During a median follow-up of 21 months (interquartile range: 13–36), 73 deaths occurred. Global X 2 was 49.5 considering clinical variables, 50.7 after step A only (P = NS (not significant)) and 80.6 after B–E steps (P < 0.001 vs. step A). Annual mortality rate ranged from 0.4% person-year for score 0 up to 2.7% person-year for score 5. ABCDE-SE allows an effective prediction of survival in patients with chronic coronary syndromes. This study recruited 3,574 patients from 13 stress echo laboratories of 5 countries and shows the prognostic value of the new state-of-the art cardiac functional testing with stress echo ABCDE protocol: Step A for regional wall motion abnormalities; step B for B-lines obtained with 4-site simplified scan and lung ultrasound; step C for contractile reserve with volumetric echocardiography; step D for Doppler-based assessment of coronary flow reserve in mid-distal left anterior descending coronary artery; step E for EKG-based heart rate reserve.

17 August 2021 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
EPEugenio Picano
Eugenio Picano
QCQuirino Ciampi
Quirino Ciampi
LCLauro Cortigiani
Lauro Cortigiani
AAAdelaide M. Arruda-Olson
Adelaide M. Arruda-Olson
Clarissa Borguezan DarosClarissa Borguezan Daros
Clarissa Borguezan Daros
T(The Stress Echo 2030 Study Group of the Italian Society of Echocardiography and Cardiovascular Imaging (SIECVI)
The Stress Echo 2030 Study Group of the Italian Society of Echocardiography and Cardiovascular Imaging (SIECVI)
With stress echo (SE) 2020 study, a new standard of practice in stress imaging was developed and disseminated: the ABCDE protocol for functional testing within and beyond CAD. ABCDE protocol was the fruit of SE 2020, and is the seed of SE 2030, which is articulated in 12 projects: 1-SE in coronary artery disease (SECAD); 2-SE in diastolic heart failure (SEDIA); 3-SE in hypertrophic cardiomyopathy (SEHCA); 4-SE post-chest radiotherapy and chemotherapy (SERA); 5-Artificial intelligence SE evaluation (AI-SEE); 6-Environmental stress echocardiography and air pollution (ESTER); 7-SE in repaired Tetralogy of Fallot (SETOF); 8-SE in post-COVID-19 (SECOV); 9: Recovery by stress echo of conventionally unfit donor good hearts (RESURGE); 10-SE for mitral ischemic regurgitation (SEMIR); 11-SE in valvular heart disease (SEVA); 12-SE for coronary vasospasm (SESPASM). The study aims to recruit in the next 5 years (2021–2025) ≥10,000 patients followed for ≥5 years (up to 2030) from ≥20 quality-controlled laboratories from ≥10 countries. In this COVID-19 era of sustainable health care delivery, SE2030 will provide the evidence to finally recommend SE as the optimal and versatile imaging modality for functional testing anywhere, any time, and in any patient.

2 October 2018 in Cardiovascular Ultrasound
Verified
Journal Article
Open access
PDF file
EPEugenio Picano
Eugenio Picano
QCQuirino Ciampi
Quirino Ciampi
KWKarina Wierzbowska-Drabik
Karina Wierzbowska-Drabik
MUMădălina-Loredana Urluescu
Mădălina-Loredana Urluescu
DMDoralisa Morrone
Doralisa Morrone
CCClara Carpeggiani
Clara Carpeggiani
The detection of regional wall motion abnormalities is the cornerstone of stress echocardiography. Today, stress echo shows increasing trends of utilization due to growing concerns for radiation risk, higher cost and stronger environmental impact of competing techniques. However, it has also limitations: underused ability to identify factors of clinical vulnerability outside coronary artery stenosis; operator-dependence; low positivity rate in contemporary populations; intermediate risk associated with a negative test; limited value of wall motion beyond coronary artery disease. Nevertheless, stress echo has potential to adapt to a changing environment and overcome its current limitations. Four parameters now converge conceptually, logistically, and methodologically in the Integrated Quadruple (IQ)-stress echo. They are: 1- regional wall motion abnormalities; 2-B-lines measured by lung ultrasound; 3-left ventricular contractile reserve assessed as the stress/rest ratio of force (systolic arterial pressure by cuff sphygmomanometer/end-systolic volume from 2D); 4- coronary flow velocity reserve on left anterior descending coronary artery (with color-Doppler guided pulsed wave Doppler). IQ-Stress echo allows a synoptic functional assessment of epicardial coronary artery stenosis (wall motion), lung water (B-lines), myocardial function (left ventricular contractile reserve) and coronary small vessels (coronary flow velocity reserve in mid or distal left anterior descending artery). In “ABCD” protocol, A stands for Asynergy (ischemic vs non-ischemic heart); B for B-lines (wet vs dry lung); C for Contractile reserve (weak vs strong heart); D for Doppler flowmetry (warm vs cold heart, since the hyperemic blood flow increases the local temperature of the myocardium). From the technical (acquisition/analysis) viewpoint and required training, B-lines are the kindergarten, left ventricular contractile reserve the primary (for acquisition) and secondary (for analysis) school, wall motion the university, and coronary flow velocity reserve the PhD program of stress echo. Stress echo is changing. As an old landline telephone with only one function, yesterday stress echo used one sign (regional wall motion abnormalities) for one patient with coronary artery disease. As a versatile smart-phone with multiple applications, stress echo today uses many signs for different pathophysiological and clinical targets. Large scale effectiveness studies are now in progress in the Stress Echo2020 project with the omnivorous “ABCD” protocol.

1 May 2022 in Circulation: Cardiovascular Imaging
Verified
Journal Article
Open access
PDF file
EMElisa Merli
Elisa Merli
QCQuirino Ciampi
Quirino Ciampi
MSMaria Chiara Scali
Maria Chiara Scali
AZAngela Zagatina
Angela Zagatina
PMPablo Martin Merlo
Pablo Martin Merlo
O(on behalf of Stress Echo 2020 and 2030 study group of the Italian Society of Echocardiography and Cardiovascular Imaging (SIECVI)
on behalf of Stress Echo 2020 and 2030 study group of the Italian Society of Echocardiography and Cardiovascular Imaging (SIECVI)
Background: Lung ultrasound detects pulmonary congestion as B-lines at rest, and more frequently, during exercise stress echocardiography (ESE). Methods: We performed ESE plus lung ultrasound (4-site simplified scan) in 4392 subjects referred for semi-supine bike ESE in 24 certified centers in 9 countries. B-line score ranged from 0 (normal) to 40 (severely abnormal). Five different populations were evaluated: control subjects (n=103); chronic coronary syndromes (n=3701); heart failure with reduced ejection fraction (n=395); heart failure with preserved ejection fraction (n=70); ischemic mitral regurgitation ≥ moderate at rest (n=123). In a subset of 2478 patients, follow-up information was available. Results: During ESE, B-lines increased in all study groups except controls. Age, hypertension, abnormal ejection fraction, peak wall motion score index, and abnormal heart rate reserve were associated with B-lines in multivariable regression analysis. Stress B lines (hazard ratio, 2.179 [95% CI, 1.015–4.680]; P =0.046) and ejection fraction <50% (hazard ratio, 2.942 [95% CI, 1.268–6.822]; P =0.012) were independent predictors of all-cause death (n=29 after a median follow-up of 29 months). Conclusions: B-lines identify the pulmonary congestion phenotype at rest, and more frequently, during ESE in ischemic and heart failure patients. Stress B-lines may help to refine risk stratification in these patients. Registration: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT 03049995.

13 February 2014 in The International Journal of Cardiovascular Imaging
Verified
Journal Article
Open access
PDF file
KWKarina Wierzbowska-Drabik
Karina Wierzbowska-Drabik
PHPiotr Hamala
Piotr Hamala
NRNikolina Roszczyk
Nikolina Roszczyk
PLPiotr Lipiec
Piotr Lipiec
MPMichał Plewka
Michał Plewka
JKJarosław Damian Kasprzak
Jarosław Damian Kasprzak
Speckle tracking echocardiography (STE) is a method of quantitative assessment of myocardial function complementary to ejection fraction and visual evaluation. Standard STE analysis, demands manual tracing of the myocardium whereas automated function imaging (AFI) offers more convenient (based on selection of three points) assessment of longitudinal strain. Nevertheless, feasibility and correlation between both methods were not thoroughly examined, especially during tachycardia at peak stage of dobutamine stress echocardiography (DSE). We performed DSE in 238 patients (pts) with recording of apical views during baseline (0) and peak (1) DSE and analyzed them by STE and AFI. According to angiography, 127/238 pts had significant (≥70 %) lesions in coronary arteries. We assessed correlations between STE and AFI derived peak systolic longitudinal strain values for global and regional parameters, feasibility, time of analysis and interobserver agreement. Global systolic longitudinal strain measured during baseline and peak stage of DSE by AFI showed very good correlation with standard STE parameters, with correlation coefficients r = 0.90 and r = 0.86 respectively (p < 0.0001). For regional parameters correlation coefficients ranged from 0.83 to 0.85 for baseline and from 0.70 to 0.79 for peak DSE. Both methods provided good and similar feasibility with only 1 % segments excluded from analysis at peak stage of DSE with shorter time and lower coefficient of variance offered by AFI. Global and regional longitudinal strain achieved by faster and less operator-dependent AFI method correlate well with standard more time-consuming STE analysis during baseline and peak stage of DSE.

15 March 2013 in Echocardiography
Verified
Journal Article
Closed access
PDF file
KWKarina Wierzbowska-Drabik
Karina Wierzbowska-Drabik
ŁCŁukasz Chrzanowski
Łukasz Chrzanowski
AKAnna Kapusta
Anna Kapusta
BUBarbara Uznańska‐Loch
Barbara Uznańska‐Loch
EPEdyta Płońska
Edyta Płońska
JKJarosław D. Kasprzak
Jarosław D. Kasprzak