The minimum energy required after bridge-burst to function a commercially available RP-1 exploding bridgewire detonator with a gold bridgewire was investigated using two capacitor discharge units (CDUs) making use of state-of-the-art on/off high-voltage high-current switches. Both switches are capable of shutting off the current flow in ≈ 100 ns and the conduction time was varied systematically to limit the duration of electrical energy delivered from the CDU until a detonation go/no-go threshold was reached. It was found that the minimal extra electrical energy required for a soft-fire (a statistically marginal go) was approximately half that required for a hard-fire (a definite go). The measured energy required to function the RP-1 detonator from the 11.5 kV CDU was approximately 20 mJ greater than for the 600 V CDU, and it is postulated that this was due to arcing across the detonator terminals and an associated current shunt that was not efficient at depositing energy conducive to detonator functioning. Measurements of the bridgewire temperatures bursting in air showed that the maximum temperature reached was consistent ( ≈ 18 kK ) when sufficient energy was delivered that the detonator functioned (either soft- or hard-fire), but that the temperature for a sub-threshold bridgewire burst was significantly cooler at approximately 8 kK. Furthermore, it was demonstrated that the intensity of the light emitted at burst scaled with deposited energy. A related finding is that the light emission from the bridgewire peaks some tens of nanoseconds after both peak voltage and peak electrical power.

27 April 2020 in bioRxiv
Verified
Preprint
Open access
PDF file
DWDiana Wu
Diana Wu
TFTrevor Fegain
Trevor Fegain
PMPeter Mage
Peter Mage
ARAlexandra Rangel
Alexandra Rangel
LWLeighton Wan
Leighton Wan
SPSharon Pitteri
Sharon Pitteri
Aptamers incorporating chemically modified bases can achieve superior affinity and specificity compared to natural aptamers, but their characterization remains a labor-intensive, low-throughput task. Here we describe the ‘non-natural aptamer array’ (N2A2) system, in which a minimally modified Illumina MiSeq instrument is used for the high-throughput generation and characterization of large libraries (∼10 6 ) of base-modified DNA aptamer candidates on the basis of both target affinity and specificity. We first demonstrate the capability to screen multiple different base modifications to identify the optimal chemistry for high-affinity target binding. We next use N2A2 to generate aptamers that can maintain excellent specificity even in complex samples, with equally strong target affinity in both buffer and diluted human serum. Given that N2A2 requires only minor mechanical modifications to the MiSeq, we believe N2A2 offers a broadly accessible tool for generating high-quality affinity reagents for diverse applications.

18 June 2022 in Combustion and Flame
Verified
Journal Article
Closed access
TFTrevor Fegain
Trevor Fegain
EHEric M. Heatwole
Eric M. Heatwole
DEDavid Eastwood
David Eastwood
ILIan Lopez-Pulliam
Ian Lopez-Pulliam
TCThomas Connolley
Thomas Connolley
GPGary R. Parker
Gary R. Parker

2 April 2021 in Scientific Reports
Verified
Journal Article
Open access
PDF file
TFTrevor Fegain
Trevor Fegain
EHE. M. Heatwole
E. M. Heatwole
PRP. J. Rae
P. J. Rae
RRR. C. Rettinger
R. C. Rettinger
GPG. R. Parker
G. R. Parker
Electrically exploded wires find uses throughout high-energy physics. For example, they are commonly used as high-temperature sources, X-ray generators, and in precision timing detonators. However, the detailed and complete physics that occurs is complex and still poorly understood. A full mechanistic description of these complex phenomena is beyond the scope of a single paper. Instead, we focus on the formation of metal vapor and its transition to plasma. This single transition is commonly assumed to comprise “bridge-burst”. We use a suite of diagnostics including a novel, fiber-based, high-speed, optical pyrometer to better characterize this transition. The primary finding from this project is that peak light output from an exploding wire does not temporally match the peak temperature. Additionally, it is found that peak light does not align with peak bridge-burst voltage and that the peak temperature is not voltage-dependent. These findings are non-intuitive and will allow for the correction of false assumptions previously made about this topic.

23 November 2020
Verified
Report
Closed access
PDF file
MHMatthew David Holmes
Matthew David Holmes
EHEric Heatwole
Eric Heatwole
RBRobert M. Broilo
Robert M. Broilo
PSPeter Schulze
Peter Schulze
TFTrevor Fegain
Trevor Fegain
GJGary Parker Jr.
Gary Parker Jr.
The U.S. Department of Energy's Office of Scientific and Technical Information

10 November 2020
Verified
Report
Closed access
PDF file
MHMatthew David Holmes
Matthew David Holmes
RBRobert M. Broilo
Robert M. Broilo
RRRyan Rettinger
Ryan Rettinger
ABAndrew Thomas Barnes
Andrew Thomas Barnes
EHEric Heatwole
Eric Heatwole
GPGary Parker
Gary Parker
The U.S. Department of Energy's Office of Scientific and Technical Information