Motor current signature analysis (MCSA) for fault detection has found widespread application, especially for induction motors. The basis of MCSA is the evaluation of a motor's current. This analysis is now also used for other motor types and can be used to detect faults of the coupled load. The purpose of this article is to examine whether MCSA can be used to detect faults in a wet-rotor pump. A total of three faults are examined. The results show that, compared with a healthy pump, all faults could be detected. However, a detailed analysis of frequency components has to be carried out to differentiate the faults. A circulation pump with a maximum power consumption of 1.1 kW was used as the test item.
Pumps have a wide range of applications. Methods for fault detection of motors are increasingly being used for pumps. In the context of this paper, a test bench is built to investigate circulation pumps for faults. As a use case, the fault of impeller clogging was first measured and then examined with the help of motor current signature analysis. It can be seen that there are four frequencies at which there is an increase in amplitude in case of a fault. The sidebands around the supply frequency are in particular focus. The clogging of three and four of a total of seven channels leads to the highest amplitudes at the fault frequencies. The efficiency is reduced by 9 to 15% in case of faulty operation. These results indicate that the implementation of fault detection algorithms on the pump electronics represents added value for the pump operator. Furthermore, the results can be transferred to other applications.