Marc-André Avondet

Mr. Marc-André Avondet


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 November 2015 in Toxins
Verified
Journal Article
Open access
PDF file
JWJasmin Weisemann
Jasmin Weisemann
NKNadja Krez
Nadja Krez
UFUwe Fiebig
Uwe Fiebig
SWSylvia Worbs
Sylvia Worbs
MSMartin Skiba
Martin Skiba
Andreas RummelAndreas Rummel
Andreas Rummel
The detection and identification of botulinum neurotoxins (BoNT) is complex due to the existence of seven serotypes, derived mosaic toxins and more than 40 subtypes. Expert laboratories currently use different technical approaches to detect, identify and quantify BoNT, but due to the lack of (certified) reference materials, analytical results can hardly be compared. In this study, the six BoNT/A1–F1 prototypes were successfully produced by recombinant techniques, facilitating handling, as well as improving purity, yield, reproducibility and biosafety. All six BoNTs were quantitatively nicked into active di-chain toxins linked by a disulfide bridge. The materials were thoroughly characterized with respect to purity, identity, protein concentration, catalytic and biological activities. For BoNT/A1, B1 and E1, serotypes pathogenic to humans, the catalytic activity and the precise protein concentration were determined by Endopep-mass spectrometry and validated amino acid analysis, respectively. In addition, BoNT/A1, B1, E1 and F1 were successfully detected by immunological assays, unambiguously identified by mass spectrometric-based methods, and their specific activities were assigned by the mouse LD50 bioassay. The potencies of all six BoNT/A1–F1 were quantified by the ex vivo mouse phrenic nerve hemidiaphragm assay, allowing a direct comparison. In conclusion, highly pure recombinant BoNT reference materials were produced, thoroughly characterized and employed as spiking material in a worldwide BoNT proficiency test organized by the EQuATox consortium.

26 November 2015 in Toxins
Verified
Journal Article
Open access
PDF file
SSStéphanie Simon
Stéphanie Simon
SWSylvia Worbs
Sylvia Worbs
MAMarc-André Avondet
Marc-André Avondet
DTDobryan M. Tracz
Dobryan M. Tracz
JDJulie Dano
Julie Dano
CCCindi Corbett
Cindi Corbett
Ricin, a toxin from the plant Ricinus communis, is one of the most toxic biological agents known. Due to its availability, toxicity, ease of production and absence of curative treatments, ricin has been classified by the Centers for Disease Control and Prevention (CDC) as category B biological weapon and it is scheduled as a List 1 compound in the Chemical Weapons Convention. An international proficiency test (PT) was conducted to evaluate detection and quantification capabilities of 17 expert laboratories. In this exercise one goal was to analyse the laboratories’ capacity to detect and differentiate ricin and the less toxic, but highly homologuous protein R. communis agglutinin (RCA120). Six analytical strategies are presented in this paper based on immunological assays (four immunoenzymatic assays and two immunochromatographic tests). Using these immunological methods “dangerous” samples containing ricin and/or RCA120 were successfully identified. Based on different antibodies used the detection and quantification of ricin and RCA120 was successful. The ricin PT highlighted the performance of different immunological approaches that are exemplarily recommended for highly sensitive and precise quantification of ricin.

13 September 2016 in Toxins
Verified
Journal Article
Open access
PDF file
YNYacine Nia
Yacine Nia
MRMélanie Rodriguez
Mélanie Rodriguez
RZReinhard Zeleny
Reinhard Zeleny
SHSabine Herbin
Sabine Herbin
FAFrederic Auvray
Frederic Auvray
JHJacques-Antoine Hennekinne
Jacques-Antoine Hennekinne
The aim of this work was to organize the first proficiency test (PT) dedicated to staphylococcal enterotoxin B (SEB) detection in milk and buffer solutions. This paper describes the organization of the PT trial according to EN ISO 17043 requirements. Characterization of the SEB stock solution was performed using SDS-PAGE and SE-specific ELISA, and amino acid analysis was used to assign its protein concentration. The solution was then used to prepare six PT materials (four milk and two buffer batches) at a ng/g toxin level, which included one blank and one SEA-containing milk as specificity control. Suitable material homogeneity and stability were assessed using screening and quantitative ELISAs. Among the methods used by the participants, ELISA-based methods demonstrated their efficiency for the detection of SEB in both simple and complex matrices. The results serve as a basis for further improving the detection capabilities in expert laboratories and can therefore be considered as a contribution to biopreparedness.

9 February 2019 in Toxins
Verified
Journal Article
Open access
PDF file
JTJenna Tonacini
Jenna Tonacini
DSDario Stephan
Dario Stephan
GVGuido Vogel
Guido Vogel
MAMarc-André Avondet
Marc-André Avondet
FKFranka Kalman
Franka Kalman
BSBruno Schnyder
Bruno Schnyder
Routine identification of pathogens by MALDI-TOF MS (matrix-assisted laser desorption ionisation time-of-flight mass spectrometry) is based on the fingerprint of intracellular proteins. This work evaluated the use of MALDI-TOF MS for the identification of extracellular pathogen factors. A Staphylococcus aureus isolate from a food contaminant was exponentially grown in liquid cultures. Secreted proteins were collected using methanol– chloroform precipitation and analysed by MALDI-TOF MS. A main peak m/z 28,250 was demonstrated, which was identified as S.aureus enterotoxin type B (SEB) by using the pure authentic SEB reference of 28.2 kDa and by amino acid sequence analysis. SEB was also detected in this intact form following pasteurization and cooking treatments. Further application of the elaborated MALDI-TOF MS protocol resulted in the detection of SEA at m/z 27,032 and SEC at m/z 27,629. In conclusion, a simple sample preparation from S.aureus cultures and an easy-to-perform identification of pathogen factors SE in intact form represents a promising next-generation application of MALDI-TOF MS.

25 November 2015 in Toxins
Verified
Journal Article
Open access
PDF file
KHKirsi Harju
Kirsi Harju
MRMarja-Leena Rapinoja
Marja-Leena Rapinoja
MAMarc-André Avondet
Marc-André Avondet
WAWerner Arnold
Werner Arnold
MSMartin Schär
Martin Schär
PVPaula Sinikka Vanninen
Paula Sinikka Vanninen
Saxitoxin (STX) and some selected paralytic shellfish poisoning (PSP) analogues in mussel samples were identified and quantified with liquid chromatography-tandem mass spectrometry (LC-MS/MS). Sample extraction and purification methods of mussel sample were optimized for LC-MS/MS analysis. The developed method was applied to the analysis of the homogenized mussel samples in the proficiency test (PT) within the EQuATox project (Establishment of Quality Assurance for the Detection of Biological Toxins of Potential Bioterrorism Risk). Ten laboratories from eight countries participated in the STX PT. Identification of PSP toxins in naturally contaminated mussel samples was performed by comparison of product ion spectra and retention times with those of reference standards. The quantitative results were obtained with LC-MS/MS by spiking reference standards in toxic mussel extracts. The results were within the z-score of ±1 when compared to the results measured with the official AOAC (Association of Official Analytical Chemists) method 2005.06, pre-column oxidation high-performance liquid chromatography with fluorescence detection (HPLC-FLD).

25 November 2015 in Toxins
Verified
Journal Article
Open access
PDF file
KHKirsi Harju
Kirsi Harju
MRMarja-Leena Rapinoja
Marja-Leena Rapinoja
MAMarc-André Avondet
Marc-André Avondet
WAWerner Arnold
Werner Arnold
MSMartin Schär
Martin Schär
PVPaula Sinikka Vanninen
Paula Sinikka Vanninen
A saxitoxin (STX) proficiency test (PT) was organized as part of the Establishment of Quality Assurance for the Detection of Biological Toxins of Potential Bioterrorism Risk (EQuATox) project. The aim of this PT was to provide an evaluation of existing methods and the European laboratories’ capabilities for the analysis of STX and some of its analogues in real samples. Homogenized mussel material and algal cell materials containing paralytic shellfish poisoning (PSP) toxins were produced as reference sample matrices. The reference material was characterized using various analytical methods. Acidified algal extract samples at two concentration levels were prepared from a bulk culture of PSP toxins producing dinoflagellate Alexandrium ostenfeldii. The homogeneity and stability of the prepared PT samples were studied and found to be fit-for-purpose. Thereafter, eight STX PT samples were sent to ten participating laboratories from eight countries. The PT offered the participating laboratories the possibility to assess their performance regarding the qualitative and quantitative detection of PSP toxins. Various techniques such as official Association of Official Analytical Chemists (AOAC) methods, immunoassays, and liquid chromatography-mass spectrometry were used for sample analyses.