WEI CAO

Dr. WEI CAO

Department of Nuclear Medicine, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, China
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2020 in Journal of Thoracic Disease
Verified
Journal Article
Open access
PDF file
HLHaiyan Li
Haiyan Li
WCWEI CAO
WEI CAO
Pulmonary enteric adenocarcinoma (PEAC) is an extremely rare type of non-small cell lung cancer (NSCLC) with a histologic pattern that mimics metastatic colorectal cancer (MCC). The main clinical symptoms in PEAC patients are dyspnoea, coughing, hemoptysis, and chest and back pain. The first article about PEAC appeared in 1991 in the form of a case report. As a variant of invasive lung carcinoma, only a small number of case reports and clinical research studies have been carried out, and the only one guidance on diagnosis and treatment is the WHO Tumor Classification book. It is important for doctors to distinguish PEAC from MCC to extend survival time and improve the quality of life. We reviewed the existing literature regarding the diagnosis, treatment, and prognosis of PEAC to provide some valuable clinical references.

28 October 2024 in Scientific Reports
Verified
Journal Article
Open access
PDF file
YLYu Liu
Yu Liu
MLMengting Li
Mengting Li
HCHong Chen
Hong Chen
WLWei Liu
Wei Liu
MHMengmeng Hu
Mengmeng Hu
XXXiaotian Xia
Xiaotian Xia
To explore the performance of 99mTc-diethylene triaminepentaacetic acid (DTPA) SPECT/CT texture analysis in evaluating the activity of thyroid-associated ophthalmopathy (TAO) . This retrospective study examined 115 TAO patients from a single institution as an internal cohort and 58 TAO patients from another institution as an external validation set. Patients in the internal cohort were randomly divided into training (n = 81) and internal validation sets (n = 34). Radiomics signatures were constructed with the minimal redundancy maximal relevance and least absolute shrinkage and selection operator algorithms in training set. Multivariate logistic regression analysis was used to develop a clinical model and a combined clinical–radiomics model. Diagnostic performance of models was evaluated using receiver operating characteristic curve analysis, calibration curves and decision curve analysis. Compared with CT and SPECT radiomics models, Rad-scoreSPECT/CT demonstrated the best performance with areas under the receiver operating characteristic curve of 0.94 and 0.91 in the training and test sets, respectively. The combined clinical-radiomics model exhibited significantly better performance in evaluating TAO activity. Our results demonstrate the validity of a multimodal radiomic model of 99mTc-DTPA-SPECT/CT to assess TAO activity. The combined clinical-radiomics model exhibited significantly better diagnostic performance than the clinical model.

15 July 2015 in Clinical Imaging
Verified
Journal Article
Closed access
PDF file
RJRi-Feng Jiang
Ri-Feng Jiang
LZLiang Zhang
Liang Zhang
BCBo Cheng
Bo Cheng
ZHZheng Huang
Zheng Huang
DLDuo-Lan Li
Duo-Lan Li
WCWEI CAO
WEI CAO

27 March 2023 in Frontiers in Medicine
Verified
Journal Article
Open access
YDYing Ding
Ying Ding
YLYu Liu
Yu Liu
LZLi Zhang
Li Zhang
YDYinqian Deng
Yinqian Deng
HCHuanyu Chen
Huanyu Chen
WCWEI CAO
WEI CAO
Background: Early detection of kidney diseases can be challenging as conventional methods such as blood tests or imaging techniques (computed tomography (CT), magnetic resonance imaging (MRI), or ultrasonography) may be insufficient to assess renal function. A single-photon emission CT (SPECT) renal scan provides a means of measuring glomerular filtration rates (GFRs), but its diagnostic accuracy is limited due to its planar imaging modality and semi-quantification property. In this study, we aimed to improve the accuracy of GFR measurement by preparing a positron emission tonometry (PET) tracer 68Ga-Ethylenediaminetetraacetic acid (68Ga-EDTA) and comprehensively evaluating its performance in healthy mice and murine models of renal dysfunction.Methods: Dynamic PET scans were performed in healthy C57BL/6 mice and in models of renal injury, including acute kidney injury (AKI) and unilateral ureter obstruction (UUO) using 68Ga-EDTA. In a 30-min dynamic scan, PET images and time-activity curves (TACs) were acquired. Renal function and GFR values were measured using renograms and validated through serum renal function parameters, biodistribution results, and pathological staining.Results: 68Ga-EDTA dynamic PET imaging quantitatively captured the tracer elimination process. The calculated GFR values were 0.25 ± 0.02 ml/min in healthy mice, 0.01 ± 0.00 ml/min in AKI mice, and 0.25 ± 0.04, 0.29 ± 0.03 and 0.24 ± 0.01 ml/min in UUO mice, respectively. Furthermore, 68Ga-EDTA dynamic PET imaging and GFRPET were able to differentiate mild renal impairment before serum parameters indicated any changes.Conclusions: Our findings demonstrate that 68Ga-EDTA dynamic PET provides a reliable and precise means of evaluating renal function in two murine models of renal injury. These results hold promise for the widespread clinical application of 68Ga-EDTA dynamic PET in the near future.

1 December 2020 in The Annals of Thoracic Surgery
Verified
Journal Article
Closed access
XXXiaotian Xia
Xiaotian Xia
FSFuqiang Shao
Fuqiang Shao
FHFan Hu
Fan Hu
YHYong He
Yong He
WCWEI CAO
WEI CAO

1 January 2022
Verified
Journal Article
Closed access
YDYing Ding
Ying Ding
DZDu Zhang
Du Zhang
MWMin Wang
Min Wang
LZLi Zhang
Li Zhang
YLYu Liu
Yu Liu
WCWEI CAO
WEI CAO