Objective. Electrical stimulation of the peripheral nervous system (PNS) can treat various diseases and disorders, including the healing process after nerve injury. A major challenge when designing electrodes for PNS stimulation is the mechanical mismatch between the nerve and the device, which can lead to non-conformal contact, tissue damage and inefficient stimulation due to current leakage. Soft and stretchable cuff electrodes promise to tackle these challenges but often have limited performance and rely on unconventional materials. The aim of this study is to develop a high performance soft and stretchable cuff electrode based on inert materials for low-voltage nerve stimulation. Approach. We developed 50 µm thick stretchable cuff electrodes based on silicone rubber, gold nanowire conductors and platinum coated nanowire electrodes. The electrode performance was characterized under strain cycling to assess the durability of the electrodes. The stimulation capability of the cuff electrodes was evaluated in an in vivo sciatic nerve rat model by measuring the electromyography response to various stimulation pulses. Main results. The stretchable cuff electrodes showed excellent stability for 50% strain cycling and one million stimulation pulses. Saturated homogeneous stimulation of the sciatic nerve was achieved at only 200 mV due to the excellent conformability of the electrodes, the low conductor resistance (0.3 Ohm sq−1), and the low electrode impedance. Significance. The developed stretchable cuff electrode combines favourable mechanical properties and good electrode performance with inert and stable materials, making it ideal for low power supply applications within bioelectronic medicine.
Laser Speckle Contrast Imaging (LSCI) is a non-invasive and fast technique for measuring microvascular blood flow that recently has found clinical use for burn assessment and evaluation of flaps. Tissue motion caused by for example breathing or patient movements may however affect the measurements in these clinical applications, as may distance between the camera and the skin and tissue curvature. Therefore, the aims of this study were to investigate the effect of frame rate, number of frames/image, movement of the tissue, measuring distance and tissue curvature on the measured perfusion. Methyl nicotinate-induced vasodilation in the forearm skin was measured using LSCI during controlled motion at different speeds, using different combinations of frame rate and number of frames/image, and at varying camera angles and distances. Experiments were made on healthy volunteers and on a cloth soaked in a colloidal suspension of polystyrene microspheres. Measured perfusion increased with tissue motion speed. The relation was independent of the absolute perfusion in the skin and of frame rate and number of frames/image. The measured perfusion decreased with increasing angles (16% at 60°, p = 0.01). Measured perfusion did not vary significantly between measurement distances from 15 to 40 cm (p = 0.77, %CV 0.9%). Tissue motion increases and measurement angles beyond 45° decrease the measured perfusion in LSCI. These findings have to be taken into account when LSCI is used to assess moving or curved tissue surfaces, which is common in clinical applications.
Background: The majority of breast cancer patients who receive radiation treatment are affected by acute radiation-induced skin changes. The assessment of these changes is usually done by subjective methods, which complicates the comparison between different treatments or patient groups. This study investigates the feasibility of new robust methods for monitoring skin microcirculation to objectively assess and quantify acute skin reactions during radiation treatment. Material and methods: Laser Doppler flowmetry, laser speckle contrast imaging, and polarized light spectroscopy imaging were used to measure radiation-induced changes in microvascular perfusion and red blood cell concentration (RBC) in the skin of 15 patients undergoing adjuvant radiation therapy for breast cancer. Measurements were made before treatment, once a week during treatment, and directly after the last fraction. Results: In the treated breast, perfusion and RBC concentration were increased after 1–5 fractions (2.66–13.3 Gy) compared to baseline. The largest effects were seen in the areola and the medial area. No changes in perfusion and RBC concentration were seen in the untreated breast. In contrast, Radiation Therapy Oncology Group (RTOG) scores were increased only after 2 weeks of treatment, which demonstrates the potential of the proposed methods for early assessment of skin changes. Also, there was a moderate to good correlation between the perfusion (r = 0.52) and RBC concentration (r = 0.59) and the RTOG score given a week later. Conclusion: We conclude that radiation-induced microvascular changes in the skin can be objectively measured using novel camera-based techniques before visual changes in the skin are apparent. Objective measurement of microvascular changes in the skin may be valuable in the comparison of skin reactions between different radiation treatments and possibly in predicting acute skin effects at an earlier stage.
Background: Tendon-derived extracellular matrix (ECM) hydrogel has been shown to augment tendon healing in vivo. We hypothesized that reseeding of the gel with adipose-derived stem cells (ASCs) could further assist repopulation of the gel and that combinations of growth factors (GFs) would improve the survival of these cells after reseeding. Methods: A tendon-specific ECM solution was supplemented with varying concentrations of basic fibroblast growth factor (bFGF), insulin-like growth factor–1 (IGF-1), and platelet-derived growth factor–BB (PDGF-BB). Gels were then seeded with ASCs transfected with a green fluorescent protein/luciferin construct. Cell proliferation was determined using the MTT assay and histology, and GF and ASC augmented gels were injected into the back of Sprague Dawley rats. Bioluminescence of seeded gels was continuously followed after reseeding, and cell counts were performed after the gels were explanted at 14 days. Results: Synergistic effects of the GFs were seen, and an optimal combination was determined to be 10 ng/mL bFGF, 100 ng/mL IGF-1, and 100 ng/mL PDGF-BB (2.8-fold increase; P < .05). In vivo bioluminescence showed an improved initial survival of cells in gels supplemented with the optimal concentration of GF compared with the control group (10.6-fold increase at 8 days; P < .05). Cell counts of explants showed a dramatic endogenous repopulation of gels supplemented by GF + ASCs compared with both gels with GF but no ASCs (7.6-fold increase) and gels with ASCs but no GF (1.6-fold increase). Conclusion: Synergistic effects of GFs can be used to improve cellular proliferation of ASCs seeded to a tendon ECM gel. Reseeding with ASCs stimulates endogenous repopulation of the gel in vivo and may be used to further augment tendon healing.
31 January 2023 in Advanced Materials Technologies
Bioelectronic medicine can treat diseases and disorders in humans by electrically interfacing with peripheral nerves. Multielectrode cuffs can be used for selective stimulation of portions of the nerve, which is advantageous for treatment specificity. The biocompatibility and conformability of cuffs can be improved by reducing the mechanical mismatch between nerve tissue and cuffs, but selective stimulation of nerves has yet to be achieved with soft and stretchable cuff electrodes. Here, this paper reports the development of a soft and stretchable multielectrode cuff (sMEC) for selective nerve stimulation. The device is made of 50 µm thick silicone with embedded gold nanowire conductors, which renders it functional at 50% strain, and provides superior conformability for wrapping nerves. By using different stimulation protocols, high functional selectivity is achieved with the sMEC's eight stimulation electrodes in a porcine sciatic nerve model. Finite element modeling is used to predict the potential distribution within the nerve, which correlate well with the achieved stimulation results. Recent studies are showing that mechanical softness is of outermost importance for reducing foreign body response. It is therefore believed that the soft high‐performance sMEC technology is ideal for future selective peripheral nerve interfaces for bioelectronic medicine.
19 April 2021 in Journal of Hand Surgery (European Volume)
We developed a smartphone application to measure wrist motion using the mobile device’s built-in motion sensors or connecting it via Bluetooth to a wearable sensor. Measurement of wrist motion with this method was assessed in 33 participants on two occasions and compared with those obtained with a standard goniometer. The test–retest reproducibility in healthy individuals ranged from good to excellent (intraclass correlation (ICC) 0.76–0.95) for all motions, both with and without the wearable sensor. These results improved to excellent (ICC 0.90–0.96) on the second test day, suggesting a learning effect. The day-to-day reproducibility was overall better with the wearable sensor (mean ICC 0.87) compared with the application without using sensor or goniometer (mean ICC 0.82 and 0.60, respectively). This study suggests that smartphone-based measurements of wrist range of motion are feasible and highly accurate, making it a powerful tool for outcome studies after wrist surgery.