Micro-Pirani vacuum sensors usually operate at hundreds of microwatts, which limits their application in battery-powered sensor systems. This paper reports a diode-based, low power consumption micro-Pirani vacuum sensor that has high sensitivity. Optimizations to the micro-Pirani vacuum sensor were made regarding two aspects. On the one hand, a greater temperature coefficient was obtained without increasing power consumption by taking advantage of series diodes; on the other hand, the sensor structure and geometries were redesigned to enlarge temperature variation. After that, the sensor was fabricated and tested. Test results indicated that the dynamic vacuum pressure range of the sensor was from 10−1 to 104 Pa when the forward bias current was as low as 10 μA with a power consumption of 50 μW. Average sensitivity was up to 90 μV/Pa and the sensitivity of unit power consumption increased to 1.8 V/W/Pa. In addition, the sensor could also work at a greater forward bias current for better sensor performance.
6 December 2023 in Journal of Micromechanics and Microengineering
MEMS thermal vacuum sensors have been widely applied in many academic and industry fields, and pressure range is a key performance of MEMS thermal vacuum sensors. To extend the pressure range, a combined MEMS thermal vacuum sensor that consists of two diode-type MEMS thermal vacuum sensors in series is proposed in this work. The two diode-type sensors are designed to have different areas of sensitive region and distances between sensitive region and heat sink, and their responses to the pressure are from 3.0 × 10−3 to 3 × 104 Pa and from 1.7 × 10−2 to 4.4 × 105 Pa, respectively. By series-connecting them, the combined sensor achieves a pressure range of 1.3 × 10−3 to 6.9 × 105 Pa without any additional control circuit. In addition, it possesses a relatively small size of 400 × 300 μm2. These indicate that the combined MEMS thermal vacuum sensor has the characteristics of wide pressure range, high sensitivity and small size.
2 December 2021 in Journal of Micromechanics and Microengineering
Thermopile sensors have a wide range of applications in consumer and industry. Seebeck coefficient is a basic thermal parameter of thermopile sensors. Extracting the Seebeck coefficient of both materials and thermocouple in thermopile sensors is of great importance. In this work, an on-chip test structure is designed. It consists of a substrate, a framework, supporting legs and a sensitive region which has a resistor serving as both heater and temperature detector. A set of on-chip test structures are fabricated along with a thermopile sensor. Its measurement results are analyzed and compared with apparatus measurement results. These results are consistent with each other, and the validity of structure is verified.
Microbolometer is often packaged in a vacuum atmosphere of < 1 Pa to improve its response. The internal pressure of vacuum package always drifts over time. This will lead to the response degradation of microbolometer. To maintain excellent performance and improve device lifetime, a selfcalibration method of microbolometer with vacuum package is presented. This method uses the relative change rate obtained by self-heating response to calibrate the IR response according to the linear dependence of self-heating response and IR response at different pressures. Its validity is verified using a microbolometer with series diodes. The degraded IR voltage responses can be corrected to the normal value when the internal pressure increases from 1 Pa to 500 Pa. Furthermore, the relative standard of calibration deviation is small when the internal pressure is no more than 50 Pa.
29 August 2018 in Materials Science in Semiconductor Processing