Behrooz Bahrani

Dr. Behrooz Bahrani

Department of Electrical and Computer Systems Engineering, Monash University, Clayton, VIC 3800, Australia

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2015 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
SDSuman Debnath
Suman Debnath
JQJiangchao Qin
Jiangchao Qin
Behrooz BahraniBehrooz Bahrani
Behrooz Bahrani
MSMaryam Saeedifard
Maryam Saeedifard
PBPeter Barbosa
Peter Barbosa
The modular multilevel converter (MMC) has been a subject of increasing importance for medium/high-power energy conversion systems. Over the past few years, significant research has been done to address the technical challenges associated with the operation and control of the MMC. In this paper, a general overview of the basics of operation of the MMC along with its control challenges are discussed, and a review of state-of-the-art control strategies and trends is presented. Finally, the applications of the MMC and their challenges are highlighted.

13 August 2021 in IEEE Access
Verified
Journal Article
Open access
DRDayan B. Rathnayake
Dayan B. Rathnayake
MAMilad Akrami
Milad Akrami
CPChitaranjan Phurailatpam
Chitaranjan Phurailatpam
SMSi Phu Me
Si Phu Me
SHSajjad Hadavi
Sajjad Hadavi
Behrooz BahraniBehrooz Bahrani
Behrooz Bahrani
This paper surveys current literature on modeling methods, control techniques, protection schemes, applications, and real-world implementations pertaining to grid forming inverters (GFMIs). Electric power systems are increasingly being augmented with inverter-based resources (IBRs). While having a growing share of IBRs, conventional synchronous generator-based voltage and frequency control mechanisms are still prevalent in the power industry. Therefore, IBRs are experiencing a growing demand for mimicking the behavior of synchronous generators, which is not possible with conventional grid following inverters (GFLIs). As a solution, the concept of GFMIs is currently emerging, which is drawing increased attention from academia and the industry. This paper presents a comprehensive review of GFMIs covering recent advancements in control technologies, fault ride-through capabilities, stability enhancement measures, and practical implementations. Moreover, the challenges in adding GFMIs into existing power systems, including a seamless transition from grid-connected mode to the standalone mode and vice versa, are also discussed in detail. Recently commissioned projects in Australia, the UK, and the US are taken as examples to highlight the trend in the power industry in adding GFMIs to address issues related to weak grid scenarios. Research directions in terms of voltage control, frequency control, system strength improvement, and regulatory framework are also discussed. This paper serves as a resource for researchers and power system engineers exploring solutions to the emerging problems with high penetration of IBRs, focusing on GFMIs.

18 December 2014 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
MVMohsen Vatani
Mohsen Vatani
Behrooz BahraniBehrooz Bahrani
Behrooz Bahrani
MSMaryam Saeedifard
Maryam Saeedifard
MHMorten Hovd
Morten Hovd
The modular multilevel converter (MMC) is a potential candidate for medium/high-power applications, specifically for high-voltage direct current transmission systems. One of the main challenges in the control of an MMC is to eliminate/minimize the circulating currents while the capacitor voltages are maintained balanced. This paper proposes a control strategy for the MMC using finite control set model predictive control (FCS-MPC). A bilinear mathematical model of the MMC is derived and discretized to predict the states of the MMC one step ahead. Within each switching cycle, the best switching state of the MMC is selected based on evaluation and minimization of a defined cost function. The defined cost function is aimed at the elimination of the MMC circulating currents, regulating the arm voltages, and controlling the ac-side currents. To reduce the calculation burden of the MPC, the submodule (SM) capacitor voltage balancing controller based on the conventional sorting method is combined with the proposed FCS-MPC strategy. The proposed FCS-MPC strategy determines the number of inserted/bypassed SMs within each arm of the MMC while the sorting algorithm is used to keep the SM capacitor voltages balanced. Using this strategy, only the summation of SM capacitor voltages of each arm is required for control purposes, which simplifies the communication among the SMs and the central controller. This paper also introduces a modified switching strategy, which not only reduces the calculation burden of the FCS-MPC strategy even more, but also simplifies the SM capacitor voltage balancing algorithm. In addition, this strategy reduces the SM switching frequency and power losses by avoiding the unnecessary switching transitions. The performance of the proposed strategies for a 20-level MMC is evaluated based on the time-domain simulation studies.

30 August 2010 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
Behrooz BahraniBehrooz Bahrani
Behrooz Bahrani
SKStephan Kenzelmann
Stephan Kenzelmann
Alfred RuferAlfred Rufer
Alfred Rufer
This paper presents a linear direct-quadrature current control strategy for voltage source converters (VSCs) in a rotating reference frame (RRF). The described method is based on multivariable-proportional-integral (PI) regulators and provides fast dynamics and a zero steady-state error. Contrary to the well-known conventional PI-based control strategies in RRFs, the presented method provides practically decoupled axes with a superior disturbance rejection capability. Moreover, its implementation is relatively simple and does not impose excessive structural complexity compared to its conventional PI-based competitors. The method is applicable to both single- and three-phase systems and also to anisotropic three-phase systems, e.g., synchronous motors with different direct and quadrature impedances driven by VSCs. Implementing a three-phase test system, the performance of the presented method is experimentally evaluated.

5 March 2024 in IEEE Open Journal of the Industrial Electronics Society
Verified
Journal Article
Open access
Nabil MohammedNabil Mohammed
Nabil Mohammed
HUHarith Udawatte
Harith Udawatte
WZWeihua Zhou
Weihua Zhou
DHDavid J. Hill
David J. Hill
Behrooz BahraniBehrooz Bahrani
Behrooz Bahrani
Grid-forming inverters (GFMIs) are anticipated to play a leading role in future power systems. In contrast to their counterpart grid-following inverters, which employ phase-locked loops for synchronization with the grid voltage and rely on stable grid connections, GFMIs primarily employ the power-based synchronization concept to form the voltage. Hence, they can not only stably operate in regions of the grid characterized by low strength but also provide critical ancillary services to power systems, including voltage, frequency and inertia support. Several control strategies have been employed for GFMIs, making it crucial to comprehend their stability characteristics for the analysis of small-signal stability and low-frequency oscillations. This article examines the performance of GFMIs when equipped with four different control strategies, namely: droop-based GFMI, virtual synchronous generator (VSG)-based GFMI, compensated generalized VSG (CGVSG)-based GFMI, and adaptive VSG (AVSG)-based GFMI. The comparative analysis assesses the performance and robustness of these four control strategies across various operational scenarios in frequency and time domains. Initially, the impedance-based stability analysis method is employed to evaluate these control strategies across different case studies in terms of grid strengths, grid impedance ratios, the dynamics with/without virtual impedance and inner voltage and current loops, and variations in the inverter's operating points. Subsequently, time domain verification using the electromagnetic transient models are conducted for these case studies as well as to assess the power tracking capability of these control strategies in response to changes in power references. Finally, the robustness of these four controllers is explored against external grid disturbances, including grid frequency deviations, phase jumps, and voltage sags, considering varying levels of disturbance magnitudes in both weak and strong grid connections. In conclusion, the evaluation of these control techniques in various operational scenarios reveals their strengths and weaknesses, offering valuable guidance for the selection of the most appropriate control technique to suit desired practical applications.

23 December 2010 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
Behrooz BahraniBehrooz Bahrani
Behrooz Bahrani
Alfred RuferAlfred Rufer
Alfred Rufer
SKStephan Kenzelmann
Stephan Kenzelmann
LLLuiz A. C. Lopes
Luiz A. C. Lopes
This paper presents an alternative way for the current regulation of single-phase voltage-source dc-ac converters in direct-quadrature (dq) synchronous reference frames. In a dq reference frame, ac (time varying) quantities appear as dc (time invariant) ones, allowing the controller to be designed the same as dc-dc converters, presenting infinite control gain at the steady-state operating point to achieve zero steady-state error. The common approach is to create a set of imaginary quantities orthogonal to those of the real single-phase system so as to obtain dc quantities by means of a stationary-frame to rotating-frame transformation. The orthogonal imaginary quantities in common approaches are obtained by phase shifting the real components by a quarter of the fundamental period. The introduction of such delay in the system deteriorates the dynamic response, which becomes slower and oscillatory. In the proposed approach of this paper, the orthogonal quantities are generated by an imaginary system called fictive axis, which runs concurrently with the real one. The proposed approach, which is referred to as fictive-axis emulation, effectively improves the poor dynamics of the conventional approaches while not adding excessive complexity to the controller structure.