Jeong Bong (JB) Lee

Prof. Dr. Jeong Bong (JB) Lee

Department of Electrical and Computer Engineering, The University of Texas at Dallas, Richardson, TX 75080, USA
orcid

Research Focus & Metrics

Academic Career Length

33Years (1994-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 November 2004 in Proceedings of the IEEE
Verified
Journal Article
Closed access
CAC.H. Ahn
C.H. Ahn
JCJin-Woo Choi
Jin-Woo Choi
GBG. Beaucage
G. Beaucage
JNJ.H. Nevin
J.H. Nevin
Jeong Bong (JB) LeeJeong Bong (JB) Lee
Jeong Bong (JB) Lee
RLR.J.Y. Lee
R.J.Y. Lee
This paper presents the development of a disposable plastic biochip incorporating smart passive microfluidics with embedded on-chip power sources and integrated biosensor array for applications in clinical diagnostics and point-of-care testing. The fully integrated disposable biochip is capable of precise volume control with smart microfluidic manipulation without costly on-chip microfluidic components. The biochip has a unique power source using on-chip pressurized air reservoirs, for microfluidic manipulation, avoiding the need for complex microfluidic pumps. In addition, the disposable plastic biochip has successfully been tested for the measurements of partial oxygen concentration, glucose, and lactate level in human blood using an integrated biosensor array. This paper presents details of the smart passive microfluidic system, the on-chip power source, and the biosensor array together with a detailed discussion of the plastic micromachining techniques used for chip fabrication. A handheld analyzer capable of multiparameter detection of clinically relevant parameters has also been developed to detect the signals from the cartridge type disposable biochip. The handheld analyzer developed in this work is currently the smallest analyzer capable of multiparameter detection for point-of-care testing.

3 December 2012 in ACS Applied Materials & Interfaces
Verified
Journal Article
Closed access
DKDaeyoung Kim
Daeyoung Kim
Peter ThissenPeter Thissen
Peter Thissen
GVGloria Viner
Gloria Viner
DLDong-Weon Lee
Dong-Weon Lee
WCWonjae Choi
Wonjae Choi
Jeong Bong (JB) LeeJeong Bong (JB) Lee
Jeong Bong (JB) Lee

25 April 2016 in Advanced Materials
Verified
Journal Article
Closed access
PDF file
JLJae Ah Lee
Jae Ah Lee
AAAli E. Aliev
Ali E. Aliev
JBJulia S. Bykova
Julia S. Bykova
MAMônica Jung de Andrade
Mônica Jung de Andrade
DKDaeyoung Kim
Daeyoung Kim
RBRay H. Baughman
Ray H. Baughman

6 February 2004 in Journal of Micromechanics and Microengineering
Verified
Journal Article
Closed access
KKKabseog Kim
Kabseog Kim
DPDaniel S Park
Daniel S Park
HLHong M Lu
Hong M Lu
WCWooseong Che
Wooseong Che
KKKyunghwan Kim
Kyunghwan Kim
CAChong H Ahn
Chong H Ahn
This paper presents a novel fabrication process for a tapered hollow metallic microneedle array using backside exposure of SU-8, and analytic solutions of critical buckling of a tapered hollow microneedle. An SU-8 mesa was formed on a Pyrex glass substrate and another SU-8 layer, which was spun on top of the SU-8 mesa, was exposed through the backside of the glass substrate. An array of SU-8 tapered pillar structures, with angles in the range of 3.1◦-5◦, was formed on top of the SU-8 mesa. Conformal electrodeposition of metal was carried out followed by a mechanical polishing using a planarizing polymeric layer. All organic layers were then removed to create a metallic hollow microneedle array with a fluidic reservoir on the backside. Both 200 µm and 400 µm tall, 10 by 10 arrays of metallic microneedles with inner diameters of the tip in the range of 33.6-101 µm and wall thickness of 10-20 µm were fabricated. Analytic solutions of the critical buckling of arbitrary-angled truncated cone-shaped columns are also presented. It was found that a single 400 µm tall hollow cylindrical microneedle made of electroplated nickel with a wall thickness of 20 µm, a tapered angle of 3.08◦ and a tip inner diameter of 33.6 µ mh as a critical buckling force of 1.8 N. This analytic solution can be used for square or rectangular cross-sectioned column structures with proper modifications.

22 November 2004 in Applied Physics Letters
Verified
Journal Article
Closed access
WPWounjhang Park
Wounjhang Park
Jeong Bong (JB) LeeJeong Bong (JB) Lee
Jeong Bong (JB) Lee
We report a tunable nanophotonic device concept based on flexible photonic crystal, which is comprised of a periodic array of high-index dielectric material and a low-index flexible polymer. Tunability is achieved by applying mechanical force with nano-/microelectromechanical system actuators. The mechanical stress induces changes in the periodicity of the photonic crystal and consequently modifies the photonic band structure. To demonstrate the concept, we theoretically investigated the effect of mechanical stress on the anomalous refraction behavior and observed a very wide tunability in the beam propagation direction. This concept provides a means to achieve real-time, dynamic control of photonic band structure and will thus expand the utility of photonic crystal structures in advanced nanophotonic systems.

17 November 2016 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
JJJinpyo Jeon
Jinpyo Jeon
Jeong Bong (JB) LeeJeong Bong (JB) Lee
Jeong Bong (JB) Lee
SCSang Kug Kug Chung
Sang Kug Kug Chung
DKDaeyoung Kim
Daeyoung Kim
We report magnetic-field-driven on-demand manipulation of liquid metal in microfluidic channels filled with base or acid.