Vera Belova

Ms. Vera Belova

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 March 2020 in PLOS ONE
Verified
Journal Article
Open access
PDF file
DKDmitriy Korostin
Dmitriy Korostin
NKNikolay Kulemin
Nikolay Kulemin
VNVladimir Naumov
Vladimir Naumov
VBVera Belova
Vera Belova
DKDmitriy Kwon
Dmitriy Kwon
AGAlexey Gorbachev
Alexey Gorbachev
The MGISEQ-2000 developed by MGI Tech Co. Ltd. (a subsidiary of the BGI Group) is a new competitor of such next-generation sequencing platforms as NovaSeq and HiSeq (Illumina). Its sequencing principle is based on the DNB and the cPAS technologies, which were also used in the previous version of the BGISEQ-500 device. However, the reagents for MGISEQ-2000 have been refined and the platform utilizes updated software. The cPAS method is an advanced technology based on the cPAL previously created by Complete Genomics. In this paper, the authors compare the results of the whole-genome sequencing of a DNA sample from a Russian female donor performed on MGISEQ-2000 and Illumina HiSeq 2500 (both PE150). Two platforms were compared in terms of sequencing quality, number of errors and performance. Additionally, we performed variant calling using four different software packages: Samtools mpileaup, Strelka2, Sentieon, and GATK. The accuracy of SNP detection was similar in the data generated by MGISEQ-2000 and HiSeq 2500, which was used as a reference. At the same time, a separate indel analysis of the overall error rate revealed similar FPR values and lower sensitivity. It may be concluded with confidence that the data generated by the analyzed sequencing systems is characterized by comparable magnitudes of error and that MGISEQ-2000 and HiSeq 2500 can be used interchangeably for similar tasks like whole genome sequencing.

12 January 2022 in Scientific Reports
Verified
Journal Article
Open access
PDF file
VBVera Belova
Vera Belova
APAnna Pavlova
Anna Pavlova
RARobert Afasizhev
Robert Afasizhev
VMViktoriya Moskalenko
Viktoriya Moskalenko
MKMargarita Korzhanova
Margarita Korzhanova
DKDmitriy Korostin
Dmitriy Korostin
Human exome sequencing is a classical method used in most medical genetic applications. The leaders in the field are the manufacturers of enrichment kits based on hybridization of cRNA or cDNA biotinylated probes specific for a genomic region of interest. Recently, the platforms manufactured by the Chinese company MGI Tech have become widespread in Europe and Asia. The reliability and quality of the obtained data are already beyond any doubt. However, only a few kits compatible with these sequencers can be used for such specific tasks as exome sequencing. We developed our own solution for library pre-capture pooling and exome enrichment with Agilent probes. In this work, using a set of the standard benchmark samples from the Platinum Genome collection, we demonstrate that the qualitative and quantitative parameters of our protocol which we called “RSMU_exome” exceed those of the MGI Tech kit. Our protocol allows for identifying more SNV and indels, generates fewer PCR duplicates, enables pooling of more samples in a single enrichment procedure, and requires less raw data to obtain results comparable with the MGI Tech's protocol. The cost of our protocol is also lower than that of MGI Tech's solution.

Verified
Journal Article
Open access
PDF file
ASAlexandra Semchenkova
Alexandra Semchenkova
EMEkaterina Mikhailova
Ekaterina Mikhailova
AKAlexander Y Komkov
Alexander Y Komkov
MGMarina Gaskova
Marina Gaskova
RARuslan Abasov
Ruslan Abasov
APAlexander popov
Alexander popov
We report incidence and deep molecular characteristics of lineage switch in 182 pediatric patients affected by B-cell precursor acute lymphoblastic leukemia (BCP-ALL), who were treated with blinatumomab. We documented six cases of lineage switch that occurred after or during blinatumomab exposure. Therefore, lineage conversion was found in 17.4% of all resistance cases (4/27) and 3.2% of relapses (2/63). Half of patients switched completely from BCP-ALL to CD19-negative acute myeloid leukemia, others retained CD19-positive B-blasts and acquired an additional CD19-negative blast population: myeloid or unclassifiable. Five patients had KMT2A gene rearrangements; one had TCF3::ZNF384 translocation. The presented cases showed consistency of gene rearrangements and fusion transcripts across initially diagnosed leukemia and lineage switch. In two of six patients, the clonal architecture assessed by IG/TR gene rearrangements was stable, while in others, loss of clones or gain of new clones was noted. KMT2A-r patients demonstrated very few additional mutations, while in the TCF3::ZNF384 case, lineage switch was accompanied by a large set of additional mutations. The immunophenotype of an existing leukemia sometimes changes via different mechanisms and with different additional molecular changes. Careful investigation of all BM compartments together with all molecular –minimal residual disease studies can lead to reliable identification of lineage switch.

27 January 2025 in BMC Genomics
Verified
Journal Article
Open access
PDF file
VBVera Belova
Vera Belova
IVIuliia Vasiliadis
Iuliia Vasiliadis
ZRZhanna Repinskaia
Zhanna Repinskaia
ASAlina Samitova
Alina Samitova
ASAnna Shmitko
Anna Shmitko
DKDmitriy Korostin
Dmitriy Korostin
Whole exome sequencing (WES) is essential for identifying genetic variants linked to diseases. This study compares available to date four exome enrichment kits: Agilent SureSelect Human All Exon v8, Roche KAPA HyperExome, Vazyme VAHTS Target Capture Core Exome Panel, and Nanodigmbio NEXome Plus Panel v1. We evaluated target design, coverage statistics, and variant calling accuracy across these four different exome capture products. All kits showed high target coverage, with 10x coverage exceeding 97.5% and 20x coverage above 95%. Roche exhibited the most uniform coverage, indicated by the lowest fold-80 scores, while Nanodigmbio had more on-target reads due to fewer off-target reads. Variant calling performance, evaluated using in-lab standard E701 DNA sample, showed high recall rates for all kits, especially Agilent v8. All kits achieved an F-measure above 95.87%. Nanodigmbio had the highest precision with the fewest false positives but a slightly lower F-measure than other kits. This study also highlights the performance of new solutions from Vazyme (China) and Nanodigmbio (China), which were comparable to Agilent v8 and Roche KAPA kits. These findings assist researchers and clinicians in selecting appropriate exome capture solutions.

8 February 2022 in International Journal of Systematic and Evolutionary Microbiology
Verified
Journal Article
Open access
ACAndrei Viktorovich Chaplin
Andrei Viktorovich Chaplin
VSViktoria Shcherbakova
Viktoria Shcherbakova
APAlla P. Pikina
Alla P. Pikina
ASAnastasiia Sokolova
Anastasiia Sokolova
MKMargarita Korzhanova
Margarita Korzhanova
BEBoris Efimov
Boris Efimov
Three novel strains of Gram-stain-negative, obligately anaerobic, spore-forming straight or slightly curved rods with pointed ends occurring singly or in pairs were isolated from the faeces of healthy human children. The strains were characterized by mesophilic fermentative metabolism and production of acetate, ethanol and H2 as the end metabolic products. Strains ASD3451 and ASD5720T were motile, fermented lactose and raffinose, and weakly fermented maltose. Strain ASD4241T was non-motile and did not ferment the carbohydrates listed above but fermented starch. Strains ASD3451 and ASD5720T shared average nucleotide identity higher than 98.5 % with each other, while ASD4241T had only 88.5-89 % identity to them. Based on phylogenetic and chemotaxonomic analyses, we propose Diplocloster agilis gen. nov., sp. nov. (ASD5720T=JCM 34353T=VKM B-3497T) and Diplocloster modestus sp. nov. (ASD4241T=JCM 34351T=VKM B-3498T) within the family Lachnospiraceae .

12 August 2022 in BMC Genomics
Verified
Journal Article
Open access
PDF file
VBVera Belova
Vera Belova
ASAnna Shmitko
Anna Shmitko
APAnna Pavlova
Anna Pavlova
RARobert Afasizhev
Robert Afasizhev
VCValery Cheranev
Valery Cheranev
DKDmitriy Korostin
Dmitriy Korostin
Exome sequencing is becoming a routine in health care, because it increases the chance of pinpointing the genetic cause of an individual patient's condition and thus making an accurate diagnosis. It is important for facilities providing genetic services to keep track of changes in the technology of exome capture in order to maximize throughput while reducing cost per sample. In this study, we focused on comparing the newly released exome probe set Agilent SureSelect Human All Exon v8 and the previous probe set v7. In preparation for higher throughput of exome sequencing using the DNBSEQ-G400, we evaluated target design, coverage statistics, and variants across these two different exome capture products. Although the target size of the v8 design has not changed much compared to the v7 design (35.24 Mb vs 35.8 Mb), the v8 probe design allows you to call more of SNVs (+ 3.06%) and indels (+ 8.49%) with the same number of raw reads per sample on the common target regions (34.84 Mb). Our results suggest that the new Agilent v8 probe set for exome sequencing yields better data quality than the current Agilent v7 set.