Cheng-Chen Chen

Prof. Cheng-Chen Chen

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 September 2021 in Toxics
Verified
Journal Article
Open access
PDF file
WLWu-Ting Lin
Wu-Ting Lin
CCChung-Yu Chen
Chung-Yu Chen
CLChing-Chang Lee
Ching-Chang Lee
CCCheng-Chen Chen
Cheng-Chen Chen
SLShih-Chi Lo
Shih-Chi Lo
The phthalate and semi-volatile organic compounds (SVOCs) are modern chemical substances and extensively existing in the indoor environment. The European Commission stipulated the “European Unified Test Criteria”, since 2011, for the declared specifications of building products (CEN/TS 16516), based on the “lowest concentrations of interest (LCI)”, the index pollutants, test method, and emission standard of “phthalate” and “SVOC” were specified in detail. The purpose of this study is to use six common indoor floor construction products in Taiwan (regenerated pseudoplastic rubber flooring, healthy pseudoplastic imitation wood floor, regenerated pseudoplastic rubber flooring, PVC floor tile/floor, plastic click floor, composite floor covered with carpet) to detect the changes in the concentration of phthalate emitted to the air. The ISO 16000-25 Indoor air—Part 25: Determination of the emission of semi-volatile organic compounds by building products—micro-chamber method is used to build a DS-BMEMC (glass micro-chamber: volume 630 mL), the SVOC, including phthalate, is collected in two stages, in the stable conditions of temperature 25 °C, relative humidity 50% and air change rate 2 times/h, the Stage 1 emission detection experiment (24 h) is performed, and then the Stage 2 heating-up desorption emission detection experiment (40 min air sampling) is performed, the temperature rises to 200–220 °C, the phthalate and SVOC adsorbed on the glass micro-chamber is desorbed at a high temperature to catch the air substances, the air is caught by Tenax®—TA and Florisil® adsorption tube, and then the GC/MS and LC/MSMS analysis methods are used for qualitative and emission concentration analyses of SVOC of two-stage emission, respectively. The findings show that the floor construction materials emit nine phthalate SVOCs: DEHP, DINP, DNOP, DIDP, BBP, DBP, DIBP, DEP, and DMP, the two-stage emission concentrations are different, Stage 1 (normal temperature) emission concentration of six floor construction materials is 0.01–1.2% of Stage 2 (high temperature) emission concentration, meaning the phthalate SVOC of floor construction materials is unlikely to be volatilized or emitted at normal temperature. An interesting finding is that only S3 was detected DINP 72.6 (μg/m3) in stage 1. Others were detected DINP in stage 2. This might be because S3 has carpet on the surface. This implies that floor material with carpet may have an emission of DINP at normal temperature. The result of this study refers to the limited value evaluation of EU structural material standard emission TSVOC ≤ 0.1 ug/m3, the floor building material emissions are much higher than the evaluation criteria, increasing the health risk of users. The detection method and baseline can be used as the standard for controlling the emission of phthalate SVOC of Taiwan’s green building material labeling system in the future.

17 June 2022 in Polymers
Verified
Journal Article
Open access
PDF file
YLYen-Ting Lin
Yen-Ting Lin
CWChun-Hao Wu
Chun-Hao Wu
WSWei-Lin Syu
Wei-Lin Syu
PHPo-Cheng Ho
Po-Cheng Ho
ZTZi-Ling Tseng
Zi-Ling Tseng
Ting-Yu LiuTing-Yu Liu
Ting-Yu Liu
The flexible, anti-fouling, and bionic surface-enhanced Raman scattering (SERS) biochip, which has a Nepenthes peristome-like structure, was fabricated by photolithography, replicated technology, and thermal evaporation. The pattern of the bionic Nepenthes peristome-like structure was fabricated by two layers of photolithography with SU-8 photoresist. The bionic structure was then replicated by polydimethylsiloxane (PDMS) and grafting the zwitterion polymers (2-methacryloyloxyethyl phosphorylcholine, MPC) by atmospheric plasma polymerization (PDMS-PMPC). The phospholipid monomer of MPC immobilization plays an important role; it can not only improve hydrophilicity, anti-fouling and anti-bacterial properties, and biocompatibility, but it also allows for self-driving and unidirectional water delivery. Ag nanofilms (5 nm) were deposited on a PDMS (PDMS-Ag) substrate by thermal evaporation for SERS detection. Characterizations of the bionic SERS chips were measured by a scanning electron microscope (SEM), optical microscope (OM), X-ray photoelectron spectrometer (XPS), Fourier-transform infrared spectroscopy (FTIR), and contact angle (CA) testing. The results show that the superior anti-fouling capability of proteins and bacteria (E. coli) was found on the PDMS-PMPC substrate. Furthermore, the one-way liquid transfer capability of the bionic SERS chip was successfully demonstrated, which provides for the ability to separate samples during the flow channel, and which was detected by Raman spectroscopy. The SERS intensity (adenine, 10−4 M) of PDMS-Ag with a bionic structure is ~4 times higher than PDMS-Ag without a bionic structure, due to the multi-reflection of the 3D bionic structure. The high-sensitivity bionic SERS substrate, with its self-driving water capability, has potential for biomolecule separation and detection.

14 July 2023 in Buildings
Verified
Journal Article
Open access
PDF file
YLYusen LIN
Yusen LIN
CCCheng-Chen Chen
Cheng-Chen Chen
In this study, our focus was on exploring the changing illuminance of work surfaces in different ambient uniformity spaces in the office, with a specific emphasis on sustainability and energy-saving considerations. To investigate this, we conducted a comprehensive study in a laboratory setting that replicated an office environment. The study involved the participation of 20 adults as subjects. The findings of our study revealed a strong correlation between the uniformity of ambient lighting illuminance within the indoor space and the illuminance levels observed specifically at the task plane. Notably, when the surrounding illuminance exhibited uniformity, we observed a significant reduction in the EH as adjusted by participants during VDT operation. Interestingly, the task illuminance adjusted by the subjects was lower than the usual standard. However, we did not find any significant correlation between the uniformity of indoor ambient lighting illuminance and the appropriate VDT screen luminance. In situations where energy-saving measures are required, it is crucial to maintain an even luminance in the surrounding space to ensure that the minimum lighting level in the office is upheld. Future discussions should delve into task-ambient lighting models, exploring beyond task illuminance standards alone.

9 April 2025 in Buildings
Verified
Journal Article
Open access
PDF file
SASamaneh aghajari
Samaneh aghajari
CCCheng-Chen Chen
Cheng-Chen Chen
Educational buildings are recognized as one of the largest consumers of electrical energy. Inadequate lighting can also have negative physical and psychological effects on these environments. Therefore, optimal lighting design that meets electrical energy needs while providing visual comfort is essential. Reducing glare, primarily caused by artificial lighting in educational environments, is particularly important. Glare can lead to discomfort and eye fatigue, adversely affecting learning performance. To measure and assess this phenomenon, the “Unified Glare Rating (UGR)” metric is employed, which helps designers accurately evaluate the level of glare caused by lighting. This paper examines the parameters of height and surface reflectance as variable factors to achieve an optimal design that reduces lamp demand and minimizes glare, using a three-phase methodology: (1) using Dialux software, two primary scenarios—varying heights (2.5 and 3 m) and reflectance coefficients (ceiling, walls, floor)—were examined, (2) across 100 simulations followed by correlation and regression analyses to assess the effect of each reflectance coefficient (ceiling, walls, floor) on illuminance and the UGR, and (3) energy performance evaluation. Results demonstrate trade-offs: reducing lamps from 15 to 9 lowered energy use by 40% but increased UGR from 13 to 18 (approaching the discomfort threshold of 19), while 12 lamps achieved a balance—20% energy savings, a UGR of 14, and uniformity of 0.67. Surface reflectance emerged as critical, with high-reflectance ceilings (≥85%) and walls (≥80%) contributing 50.9% and 32% to illuminance variance, respectively. This study concludes that multi-parameter optimization—integrating height, lamp quantity, and reflectance—is essential for energy-efficient classroom lighting with acceptable glare levels, providing actionable guidelines for urban educational environments constrained by artificial lighting dependency.

26 January 2023 in Energies
Verified
Journal Article
Open access
PDF file
YLYusen LIN
Yusen LIN
CCCheng-Chen Chen
Cheng-Chen Chen
Yasser Ashraf GandomiYasser Ashraf Gandomi
Yasser Ashraf Gandomi
In this work, we have studied how the vertical illuminance of the human eye position, illuminance of the horizontal work surface, and the brightness of the computer screen in the office space lighting are correlated under an energy-saving environment. This investigation was conducted in a full-scale laboratory that simulates an office space with 20 adults. It was found that when the indoor ambient lighting illuminance changes, the vertical illuminance of the subject’s eye position is affected accordingly, and the two factors are strongly correlated. On the other hand, when the surrounding environment is brighter and the vertical illuminance increases, the illuminance of the horizontal working surface adjusted by the subject during the visual display terminal (VDT) operation is significantly reduced. The horizontal illuminance value can even be lower than the value frequently employed in various countries around the world, since the computer screen brightness will be adjusted accordingly. Therefore, in an energy-saving environment, the illuminance of the horizontal working surface and the brightness of the computer screen adjusted by the users will vary with the ambient lighting. Especially in the current mainstream VDT operating environment and within a certain range of conditions, the interior setting can be lower than the current horizontal illuminance benchmark for additional energy conservation.

9 January 2024 in Engineering Proceedings
Verified
Conference Paper
Open access
PDF file
SASamaneh aghajari
Samaneh aghajari
CCCheng-Chen Chen
Cheng-Chen Chen
Unquestionably, hospital patient rooms require a proper lighting design. Dissimilar to cultural and artistic settings, where artistic discourse on light has significant importance, in medical settings, the most crucial conversation refers to standards. Research indicates that light in hospital settings has an impact on a patient’s physical and mental health. Effective lighting in medical settings can enhance the hospital’s positive experience and the speed at which patients recover from their diseases. It can also increase staff attentiveness and productivity. It is also critical to consider reducing electricity consumption in hospital settings that require lighting 24/7. Due to the high cost of lighting, access to natural light in combination with time-of-day controls minimizes energy consumption when daylight is available and impacts the hospital’s bottom line. The effect of light on hospital users was investigated in this article; therefore, it is important to understand both natural and artificial light sources in this regard. Natural light has many benefits for humans, and when it comes to electricity consumption, it is the best method because it is a free source; but, since natural light is not always available and cannot be used throughout the day, there is a need to have an artificial light source that gives the best lighting effect in terms of visual comfort and visual performance for users. Secondly, proper artificial light sources can reduce electricity consumption; hence, these two critical aspects were underlined in this study.