Maksym Tryus

Dr. Maksym Tryus

ELI Beamlines, FZU - Institute of Physics of the Czech Academy of Sciences
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 February 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
TCTimofej Chagovets
Timofej Chagovets
SSStanislav Stancek
Stanislav Stancek
Lorenzo GiuffridaLorenzo Giuffrida
Lorenzo Giuffrida
AVAndriy Velyhan
Andriy Velyhan
Maksym TryusMaksym Tryus
Maksym Tryus
Daniele MargaroneDaniele Margarone
Daniele Margarone
Fast solid target delivery and plasma-ion detection systems have been designed and developed to be used in high intensity laser-matter interaction experiments. We report on recent progress in the development and testing of automated systems to refresh solid targets at a high repetition rate during high peak power laser operation (>1 Hz), along with ion diagnostics and corresponding data collection and real-time analysis methods implemented for future use in a plasma-based ion acceleration beamline for multidisciplinary user applications.

1 April 2016 in Journal of Physics and Chemistry of Solids
Verified
Journal Article
Open access
VYV.O. Yukhymchuk
V.O. Yukhymchuk
VKV.S. Kiselov
V.S. Kiselov
MVM.Ya. Valakh
M.Ya. Valakh
Maksym TryusMaksym Tryus
Maksym Tryus
SMSkoryk Mykola
Skoryk Mykola
ABA.E. Belyaev
A.E. Belyaev

25 February 2015 in physica status solidi (c)
Verified
Journal Article
Closed access
PDF file
SDSerhiy Danylyuk
Serhiy Danylyuk
SHStefan Herbert
Stefan Herbert
PLPeter Loosen
Peter Loosen
RLRainer Lebert
Rainer Lebert
ASAnna Schäfer
Anna Schäfer
LJLarissa Juschkin
Larissa Juschkin

9 October 2022 in Quantum Beam Science
Verified
Journal Article
Open access
PDF file
FSFrancesco Schillaci
Francesco Schillaci
Lorenzo GiuffridaLorenzo Giuffrida
Lorenzo Giuffrida
Maksym TryusMaksym Tryus
Maksym Tryus
FGFilip Grepl
Filip Grepl
SSStanislav Stancek
Stanislav Stancek
Daniele MargaroneDaniele Margarone
Daniele Margarone
We report on the technological commissioning of the Laser–Plasma Ion Accelerator section of the ELIMAIA user beamline at the ELI Beamlines facility in the Czech Republic. The high-peak, high-average power L3-HAPLS laser system was used with an energy of ~10 J and pulse duration of ~30 fs on target, both in single-pulse and high repetition-rate (~0.5 Hz) mode. The laser pulse was tightly focused to reach ultrahigh intensity on target (~1021 W/cm2) and sustain such laser–plasma interaction regime during high repetition-rate operations. The laser beam, ion beam, and laser–plasma emission were monitored on a shot-to-shot basis, and online data analysis at 0.5 Hz was demonstrated through the full set of used diagnostics (e.g., far and near field, laser temporal diagnostics, X- and gamma-ray detectors, Thomson Parabola ion spectrometer, time-of-flight ion detectors, plasma imaging, etc.). The capability and reliability of the ELIMAIA Ion Accelerator was successfully demonstrated at a repetition rate of 0.5 Hz for several hundreds of consecutive laser shots.

1 June 2019 in Thin Solid Films
Verified
Journal Article
Closed access
Maksym TryusMaksym Tryus
Maksym Tryus
KNKonstantin V. Nikolaev
Konstantin V. Nikolaev
IMIgor A. Makhotkin
Igor A. Makhotkin
JSJürgen Schubert
Jürgen Schubert
LKLidia Kibkalo
Lidia Kibkalo
LJLarissa Juschkin
Larissa Juschkin

1 January 2019 in Journal of Nanoscience and Nanotechnology
Verified
Journal Article
Closed access
Maksym TryusMaksym Tryus
Maksym Tryus
SHStefan Herbert
Stefan Herbert
DWDaniel Wilson
Daniel Wilson
LBLukas Bahrenberg
Lukas Bahrenberg
SDSerhiy Danylyuk
Serhiy Danylyuk
LJLarissa Juschkin
Larissa Juschkin
Spatially resolved extreme ultraviolet reflectometry is presented in application to a local characterization of thin non-uniform contamination layers. Sample reflectivity mapping is performed, demonstrating high chemical sensitivity of the technique. Amorphous Al2O3 and carbon are determined as the contaminants of the studied silicon wafer. The results correlate with those obtained by energy-filtering photoemission electron microscopy. A laboratory tool is developed that is capable of multi-angle (2°–15°) and spectrally broadband (9.5–17 nm) extreme ultraviolet reflectometry at grazing incidence combined with a reduced sample illumination spot size, enabling spatially resolved metrology. A minimum EUV spot size of 25×30 μm in the sample plane is achieved experimentally.