Donghyun Rim

Dr. Donghyun Rim

Department of Architectural Engineering, The Pennsylvania State University, 222 Engineering Unit A, University Park, PA 16801, USA

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 September 2022 in Science
Verified
Journal Article
Closed access
NZNora Zannoni
Nora Zannoni
PLPascale S. J. Lakey
Pascale S. J. Lakey
YWYoungbo Won
Youngbo Won
MSManabu Shiraiwa
Manabu Shiraiwa
DRDonghyun Rim
Donghyun Rim
JWJonathan Williams
Jonathan Williams
Hydroxyl (OH) radicals are highly reactive species that can oxidize most pollutant gases. In this study, high concentrations of OH radicals were found when people were exposed to ozone in a climate-controlled chamber. OH concentrations calculated by two methods using measurements of total OH reactivity, speciated alkenes, and oxidation products were consistent with those obtained from a chemically explicit model. Key to establishing this human-induced oxidation field is 6-methyl-5-hepten-2-one (6-MHO), which forms when ozone reacts with the skin-oil squalene and subsequently generates OH efficiently through gas-phase reaction with ozone. A dynamic model was used to show the spatial extent of the human-generated OH oxidation field and its dependency on ozone influx through ventilation. This finding has implications for the oxidation, lifetime, and perception of chemicals indoors and, ultimately, human health.

17 May 2019 in Communications Chemistry
Verified
Journal Article
Open access
PDF file
PLPascale S. J. Lakey
Pascale S. J. Lakey
GMGlenn C. Morrison
Glenn C. Morrison
YWYoungbo Won
Youngbo Won
KPKrista M. Parry
Krista M. Parry
MDMichael von Domaros
Michael von Domaros
MSManabu Shiraiwa
Manabu Shiraiwa
Multiphase reactions of ozone with human skin oils impact indoor air quality by depleting ozone and forming semi-volatile organic compounds, which can be respiratory and skin irritants. Here we demonstrate the impact of clothing on indoor air composition and human exposure by integrating indoor chemistry modeling over a wide range of different spatial and temporal scales. Constrained by molecular dynamics simulations that provide key kinetic parameters, the kinetic model reproduces experimental measurements and predicts that squalene could persist in clothing for several hours to over a day depending on ozone concentrations. Soiled clothing protects skin from ozone exposure even with high concentrations, but can enhance concentrations of oxidation products to a ppb level depending on air exchange rates. Computational fluid dynamics simulations reveal that primary products have ~1.6–2.0 times higher concentrations in the breathing zone than in bulk room air, while secondary products are distributed more uniformly throughout a room.

16 September 2017 in Building Simulation
Verified
Journal Article
Closed access
PDF file
HAHyeunguk Ahn
Hyeunguk Ahn
DRDonghyun Rim
Donghyun Rim
LLL. James Lo
L. James Lo

1 April 2017 in Science of The Total Environment
Verified
Journal Article
Closed access
PSParichehr Salimifard
Parichehr Salimifard
DRDonghyun Rim
Donghyun Rim
CGCarlos Gomes
Carlos Gomes
PKPaul Kremer
Paul Kremer
JFJames D. Freihaut
James D. Freihaut

12 August 2021 in Communications Chemistry
Verified
Journal Article
Open access
PDF file
PLPascale S. J. Lakey
Pascale S. J. Lakey
YWYoungbo Won
Youngbo Won
DSDavid Shaw
David Shaw
FØFreja F. Østerstrøm
Freja F. Østerstrøm
JMJames Mattila
James Mattila
MSManabu Shiraiwa
Manabu Shiraiwa
Historically air constituents have been assumed to be well mixed in indoor environments, with single point measurements and box modeling representing a room or a house. Here we demonstrate that this fundamental assumption needs to be revisited through advanced model simulations and extensive measurements of bleach cleaning. We show that inorganic chlorinated products, such as hypochlorous acid and chloramines generated via multiphase reactions, exhibit spatial and vertical concentration gradients in a room, with short-lived ⋅OH radicals confined to sunlit zones, close to windows. Spatial and temporal scales of indoor constituents are modulated by rates of chemical reactions, surface interactions and building ventilation, providing critical insights for better assessments of human exposure to hazardous pollutants, as well as the transport of indoor chemicals outdoors.

30 March 2015 in PLOS ONE
Verified
Journal Article
Open access
PDF file
DRDonghyun Rim
Donghyun Rim
SSStefano Schiavon
Stefano Schiavon
WNWilliam W Nazaroff
William W Nazaroff
Providing sufficient amounts of outdoor air to occupants is a critical building function for supporting occupant health, well-being and productivity. In tropical climates, high ventilation rates require substantial amounts of energy to cool and dehumidify supply air. This study evaluates the energy consumption and associated cost for thermally conditioning outdoor air provided for building ventilation in tropical climates, considering Singapore as an example locale. We investigated the influence on energy consumption and cost of the following factors: outdoor air temperature and humidity, ventilation rate (L/s per person), indoor air temperature and humidity, air conditioning system coefficient of performance (COP), and cost of electricity. Results show that dehumidification of outdoor air accounts for more than 80% of the energy needed for building ventilation in Singapore’s tropical climate. Improved system performance and/or a small increase in the indoor temperature set point would permit relatively large ventilation rates (such as 25 L/s per person) at modest or no cost increment. Overall, even in a thermally demanding tropical climate, the energy cost associated with increasing ventilation rate up to 25 L/s per person is less than 1% of the wages of an office worker in an advanced economy like Singapore’s. This result implies that the benefits of increasing outdoor air ventilation rate up to 25 L/s per person — which is suggested to provide for productivity increases, lower sick building syndrome symptom prevalence, and reduced sick leave — can be much larger than the incremental cost of ventilation.