Coherent Raman microscopy provides label-free imaging by interrogating the intrinsic vibration of molecules. Here, we present a concept in a 100 MHz dual-comb scheme to facilitate high-speed and broadband coherent anti-Stokes Raman spectroscopic imaging based on down-converted, automatically varying delay-time in spectral focusing excitation. A rapid measurement of vibrational microspectroscopy on submicrosecond scale over a spectral span with a refresh rate of 1.2 kHz provides access to well-resolved molecular signatures within the fingerprint region. We demonstrate hyperspectral images of a mixture of spatially inhomogeneous distributions of chemical substances.
We present a baseline correction method based on improved asymmetrically reweighted penalized least squares (IarPLS) for the Raman spectrum. This method utilizes a new S-type function to reduce the risk of baseline overestimation and speed up the reweighting process. Simulated spectra with different levels of noise and measured spectra with strong fluorescence background from different samples are used to validate the performance of the proposed algorithm. Considering the drawbacks of the weighting rules for the asymmetrically reweighted penalized least squares (arPLS) method, we adapt an inverse square root unit (ISRU) function, which performs well in baseline correction. Compared with previous penalized least squares methods, such as asymmetric least squares, adaptive iteratively reweighted penalized least squares, and arPLS, experiments with the simulated Raman spectra have confirmed that the proposed method yields better outcomes. Experiments with the measured Raman spectra show that the IarPLS method can improve real Raman spectra within 20 ms. The results show that the proposed method can be successfully applied to the practical Raman spectrum as a strong basis for quantitative analysis.
Incorporating the modal and zonal estimation approaches into a unifying scheme, we introduce an improved three-dimensional shape reconstruction version of specular surfaces based on phase measuring deflectometry in this paper. The modal estimation is first implemented to derive the coarse height information of the measured surface as initial iteration values. Then the real shape can be recovered utilizing a modified zonal wavefront reconstruction algorithm to simultaneously achieve consistently high accuracy and dramatically rapid convergence. Moreover, the iterative process based on an advanced successive over-relaxation technique shows a consistent rejection of measurement errors, guaranteeing the stability and robustness in practical applications. The reconstruction results of numerical examples of the sphere, hyperbolic, and arbitrary surfaces, as well as an experimentally measured sphere mirror demonstrate the validity and efficiency of the proposed improved method. In the simulations, the proposed method increases the rate of convergence by fourfold compared with the existing zonal approach and realizes three orders of magnitude improvement in reconstruction accuracy compared with the modal technique when handling the sample points of of a sphere surface. Furthermore, the computation time decreases approximately 74.92% in contrast to the zonal estimation, and the surface error is about 6.68 μm with reconstruction points of of an experimentally measured sphere mirror. In general, this new method can be conducted with fast convergence speed and high accuracy, providing an efficient, stable, and real-time approach for shape reconstruction in practical situations.
In this paper, we introduce a flexible and simple system calibration method for specular surface metrology based on the combination of reflection rays determined by the varied points on a screen and reflection images of a plane mirror without fiducials placed at three different locations. This calibration procedure involves three steps. The camera is first calibrated based on plane patterns. Then the reflection ray directions are measured via correspondence matching. The last calibration step is the pose estimation by the orthogonal iteration algorithm and reflections in a plane mirror. Basically, the concept of replacing the coordinates of the camera center with the reflection ray can alleviate the trouble of imaging aberration. Then global optimization can be operated with the orthogonal projection defined by the reflection ray, providing precise initial values for the process of bundle adjustment, compared to the classical calibration approach directly using the local optimization algorithm. Simulations and experiments both demonstrate the validity, efficiency, and robustness of the proposed improved method. In the simulations, the proposed method achieves the absolute errors of the camera parameters within 3 pixels and the relative errors of the screen pose are below 0.5% when the noise level is 0.6 pixel. Furthermore, the calibration method shows strong anti-noise ability, relying on the application of the reflection rays and the global optimization before the final bundle adjustment. In addition, the reconstruction accuracy in our experiment improves by 60.11% by the proposed method compared with the calibration procedure, which only utilizes the bundle adjustment optimization. In general, this novel calibration method can make the measurement achieve high accuracy and robustness at a low cost and with a simple setup, providing an efficient, economical, and flexible approach for a phase measuring deflectometry system in practical situations.
We present a hybrid mode-locked Er-fiber oscillator whose repetition rate can be tuned from 101.3 to 103.0 MHz. By incorporating saturable absorption and nonlinear polarization evolution in a ring cavity, mode-locked states can be easily accessed with a 3 dB spectral range wider than 50 nm. In addition, by the combination of a computer-controlled optical delay line and a piezo actuator to change the length of the cavity, the repetition rate can be stabilized at any frequency in the tunable range for the long term. When phase locking to an Rb clock for 14 h continuously, the standard deviation of the fundamental repetition rate is 0.2 mHz with a gate time of 1 s. In addition, the feedback bandwidth can be extended to by stabilizing the 10th harmonic instead of the fundamental repetition rate. Furthermore, the linewidth of the comb modes is investigated by beating with a wavelength-tunable diode laser.
We propose an all-fiber-generated, dual-soliton, Stokes-based scheme for background-free coherent anti-Stokes Raman scattering (CARS) under the spectral focusing mechanism. Owing to the strong birefringence and high nonlinearity of a polarization-maintaining PCF (PM-PCF), two soliton pulses can be simultaneously emitted along different eigenpolarization axes and both serve as Stokes pulses, while allowing feasible tunability of frequency distance and temporal interval between them. This proposed scheme, based on an all-fiber light source, exploits a unique combination of slight frequency-shift temporal walk-off of these two solitons to achieve efficient suppression of the nonresonant background and beat the inaccessibility and complexity of the excitation source. Capability is experimentally demonstrated by background-free CARS spectroscopy and unambiguous CARS microscopy in the fingerprint region.