Hybrid electric propulsion in the aviation field is becoming an effective alternative propulsion technology with potential advantages, including fuel savings, lower pollution, and reduced noise emission. On the one hand, the aeroengine manufacturers are working to improve fuel consumption and reduce pollutant emissions with new combustion systems; on the other hand, much attention is given to reducing the weight of the batteries increasing the energy density. Hybrid electric propulsion systems (HEPS) can take advantage of the synergy between two technologies by utilizing both internal combustion engines (ICEs) and electric motors (EMs) together, each operating at their respective optimum conditions. In the present work, some numerical investigations were carried out by using a zero-dimensional code able to simulate the flight mission of a turboprop aircraft, comparing fuel consumption and pollutant emissions of the original engine with other two smaller gas turbines working in hybrid configuration. An algorithm has been implemented to calculate the weight of the batteries for the different configurations examined, evaluating the feasibility of the hybrid propulsion system in terms of number of non-revenue passengers.
Superior fuel economy, higher torque and durability have led to the diesel engine being widely used in a variety of fields of application, such as road transport, agricultural vehicles, earth moving machines and marine propulsion, as well as fixed installations for electrical power generation. However, diesel engines are plagued by high emissions of nitrogen oxides (NOx), particulate matter (PM) and carbon dioxide when conventional fuel is used. One possible solution is to use low-carbon gaseous fuel alongside diesel fuel by operating in a dual-fuel (DF) configuration, as this system provides a low implementation cost alternative for the improvement of combustion efficiency in the conventional diesel engine. An initial step in this direction involved the replacement of diesel fuel with natural gas. However, the consequent high levels of unburned hydrocarbons produced due to non-optimized engines led to a shift to carbon-free fuels, such as hydrogen. Hydrogen can be injected into the intake manifold, where it premixes with air, then the addition of a small amount of diesel fuel, auto-igniting easily, provides multiple ignition sources for the gas. To evaluate the efficiency and pollutant emissions in dual-fuel diesel-hydrogen combustion, a numerical CFD analysis was conducted and validated with the aid of experimental measurements on a research engine acquired at the test bench. The process of ignition of diesel fuel and flame propagation through a premixed air-hydrogen charge was represented the Autoignition-Induced Flame Propagation model included ANSYS-Forte software. Because of the inefficient operating conditions associated with the combustion, the methodology was significantly improved by evaluating the laminar flame speed as a function of pressure, temperature and equivalence ratio using Chemkin-Pro software. A numerical comparison was carried out among full hydrogen, full methane and different hydrogen-methane mixtures with the same energy input in each case. The use of full hydrogen was characterized by enhanced combustion, higher thermal efficiency and lower carbon emissions. However, the higher temperatures that occurred for hydrogen combustion led to higher NOx emissions.
Compression ignition engines will still be predominant in the naval sector: their high efficiency, high torque, and heavy weight perfectly suit the demands and architecture of ships. Nevertheless, recent emission legislations impose limitations to the pollutant emissions levels in this sector as well. In addition to post-treatment systems, it is necessary to reduce some pollutant species, and, therefore, the study of combustion strategies and new fuels can represent valid paths for limiting environmental harmful emissions such as CO2. The use of methane in dual fuel mode has already been implemented on existent vessels, but the progressive decarbonization will lead to the utilization of carbon-neutral or carbon-free fuels such as, in the last case, hydrogen. Thanks to its high reactivity nature, it can be helpful in the reduction of exhaust CH4. On the contrary, together with the high temperatures achieved by its oxidation, hydrogen could cause uncontrolled ignition of the premixed charge and high emissions of NOx. As a matter of fact, a source of ignition is still necessary to have better control on the whole combustion development. To this end, an optimal and specific injection strategy can help to overcome all the before-mentioned issues. In this study, three-dimensional numerical simulations have been performed with the ANSYS Forte® software (version 19.2) in an 8.8 L dual fuel engine cylinder supplied with methane, hydrogen, or hydrogen–methane blends with reference to experimental tests from the literature. A new kinetic mechanism has been used for the description of diesel fuel surrogate oxidation with a set of reactions specifically addressed for the low temperatures together with the GRIMECH 3.0 for CH4 and H2. This kinetics scheme allowed for the adequate reproduction of the ignition timing for the various mixtures used. Preliminary calculations with a one-dimensional commercial code were performed to retrieve the initial conditions of CFD calculations in the cylinder. The used approach demonstrated to be quite a reliable tool to predict the performance of a marine engine working under dual fuel mode with hydrogen-based blends at medium load. As a result, the system modelling shows that using hydrogen as fuel in the engine can achieve the same performance as diesel/natural gas, but when hydrogen totally replaces methane, CO2 is decreased up to 54% at the expense of the increase of about 76% of NOx emissions.
The authors discuss in this paper the potential of two power plant concepts for distributed generation, based on the integration of a cogenerating micro gas turbine with a solar panel array. The first one relies on the adoption of a parabolic trough network with an intermediate thermal carrier, while the second one considers the direct heating of the working air in a solar tower system. The first solution also includes a bottoming organic Rankine cycle (ORC) plant, so that it is mainly addressed to the power output increase. The second one involves a relevant temperature increase of the air entering the combustor, so allowing a direct fuel energy saving, whose amount is strongly variable with both the solar irradiance and the eventual part-load operation. In addition, the latter solar-assisted scheme involves noticeable variations in the conditions for the combustion development. This suggested the authors to proceed with a detailed CFD analysis of the combustion, after a preliminary thermal cycle study for highlighting the main benefits from the solar integration of the power plant.
5 September 2021 in SAE International Journal of Advances and Current Practices in Mobility
Methane supply in diesel engines operating in dual fuel mode has demonstrated to be effective for the reduction of particulate matter and nitric oxides emissions from this type of engine. In particular, methane is injected into the intake manifold to form a premixed charge with air, while a reduced amount of diesel oil is still directly injected to ignite the mixture inside the cylinder. As a matter of fact, the liquid fuel burns following the usual diffusive combustion, so activating the gaseous fuel oxidation in a premixed flame. Clearly, the whole combustion process appears to be more complex to be described in a CFD simulation, mainly because it is not always possible to select in the 3-dimensional codes a different combustion model for each fuel and, also, because other issues arise from the interaction of the two fuels. In this work, the Autoignition-Induced Flame Propagation model, which is included in the ANSYS Forte® tool, is applied since it represents the most appropriate model to describe the dual fuel combustion. Indeed, this model uses the G-equation to track the position and the propagation of the premixed turbulent flame, but the flame activation source is represented by the autoignition kinetics reaction scheme for the n-dodecane. The results discussed in this paper refer to experimental tests carried out on an optically accessible research engine whose real geometry and mesh were reproduced with the K3PREPW tool. Through the use of a system of sensors and optical diagnostic, the combined numerical - experimental study allows a deeper investigation of phenomena that take place in real dual fuel operations characterized by different engine speeds, 1500 and 2000 rpm, load levels, 2 and 5 bar of BMEP, injection timing and a premixed ratio between 86 and 89%.
In recent years, the use of alternative fuels in thermal engine power plants has gained more and more attention, becoming of paramount importance to overcome the use of fuels from fossil sources and to reduce polluting emissions. The present work deals with the analysis of the response to two different gas fuels—i.e., hydrogen and a syngas from agriculture product—of a 30 kW micro gas turbine integrated with a solar field. The solar field included a thermal storage system to partially cover loading requests during night hours, reducing fuel demand. Additionally, a Heat Recovery Unit was included in the plant considered and the whole plant was simulated by Thermoflex® code. Thermodynamics analysis was performed on hour-to-hour basis, for a given day as well as for 12 months; subsequently, an evaluation of cogeneration efficiency as well as energy saving was made. The results are compared against plant performance achieved with conventional natural gas fueling. After analyzing the performance of the plant through a thermodynamic analysis, the study was complemented with CFD simulations of the combustor, to evaluate the combustion development and pollutant emissions formation, particularly of NOx, with the two fuels considered using Ansys-Fluent code, and a comparison was made.