Peter Caspers

Dr. Peter Caspers

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 October 2019 in Translational Biophotonics
Verified
Journal Article
Open access
PDF file
PCPeter Caspers
Peter Caspers
CNClaudio Nico
Claudio Nico
TSTom C. Bakker Schut
Tom C. Bakker Schut
JSJohanna de Sterke
Johanna de Sterke
PPPaul D. A. Pudney
Paul D. A. Pudney
GPGerwin Puppels
Gerwin Puppels
This article describes a unique noninvasive capability to determine the concentration (in mg/cm3) and total amount of topically applied materials in the skin (in μg/cm2 of skin surface). It is based on in vivo confocal Raman spectroscopy. A theoretical derivation is given of a general method to calculate a concentration ratio from a Raman spectrum of a material in a medium, which can be a solvent or other matrix, such as the skin. A practical implementation of the method is then presented along with a clarification of the assumptions used and applied to a quantitative analysis of the in vivo skin penetration of trans‐retinol and propylene glycol (PG). A comparison was made between the concentrations profiles of retinol and PG found in the skin and the concentrations of retinol and PG that had been applied to the skin. Determination of the amount of these materials in the skin at different timepoints after topical application also enabled a straightforward calculation of the flux of materials into the skin (in μg cm−2 h).

18 September 2020 in Pharmaceutics
Verified
Journal Article
Open access
PDF file
FIFotis Iliopoulos
Fotis Iliopoulos
PCPeter Caspers
Peter Caspers
GPGerwin Puppels
Gerwin Puppels
MLMajella Lane
Majella Lane
Previously, we reported the use of Confocal Raman Spectroscopy (CRS) to investigate the topical delivery of actives and excipients. We have also correlated the results from CRS with findings from in vitro diffusion studies in human skin. However, until now CRS has only been used as a semi-quantitative method of determining the skin uptake of molecules, with results expressed as arbitrary units of signal intensity. Clearly, this posed challenges for using CRS to determine skin delivery and to assess the drug bioavailability and bioequivalence of topical formulations. In the present work, the permeation of niacinamide (NIA) from various formulations in human skin was studied in vitro using conventional Franz cells and in vivo using a quantitative CRS method under finite dose conditions. The selection of NIA was based on its wide use in pharmaceutical and personal care formulations for many years. This is the first fully quantitative study to compare these methods. The vehicles investigated were neat Transcutol® P (TC); binary combinations of propylene glycol (PG) with propylene glycol monolaurate (PGML); and ternary mixtures of PG, PGML, and isopropyl myristate (IPM). These solvents were selected to encompass a range of physicochemical properties. NIA permeation was evident from all formulations in vitro and in vivo. The vehicles PG:PGML and PG:PGML:IPM delivered comparable amounts across the skin in vitro at 24 h (100.3–106.7 µg/cm2, p > 0.05) that were significantly higher compared with those of TC (1.3 µg/cm2, p < 0.05). An excellent in vitro in vivo correlation (R2 = 0.98) was found following the linear regression of the cumulative amounts of NIA permeated in vitro and the amounts of NIA at 2 μm in the skin measured with CRS. A very good correlation between the cumulative permeation of NIA in vitro and the total amount of NIA that penetrated the stratum corneum (SC) per unit of surface area (μg/cm2) in vivo was also observed, with a Pearson correlation coefficient (R2) of 0.94. The findings support the use of CRS for the quantitative measurement of actives delivered to the skin in vivo. Future studies will focus on exploring the reproducibility and reliability of the method by investigating the delivery of different actives from a wider range of vehicles. Additionally, quantitative CRS will be evaluated further as a method for assessing the bioequivalence of topical formulations.

13 April 2021 in Pharmaceutics
Verified
Journal Article
Open access
PDF file
APAvnish Patel
Avnish Patel
FIFotis Iliopoulos
Fotis Iliopoulos
PCPeter Caspers
Peter Caspers
GPGerwin Puppels
Gerwin Puppels
MLMajella Lane
Majella Lane
The composition of topical and transdermal formulations is known to determine the rate and the extent of drug delivery to and through the skin. However, to date, the role of excipients in these formulations on skin delivery of actives has received little attention from scientists in the field. Monitoring skin absorption of both drug and vehicle may provide insights into the mechanism by which excipients promote permeation and may facilitate the design of effective and safer products. Previously, we have investigated the use of quantitative Confocal Raman Spectroscopy (CRS) to investigate the delivery of an active to the skin, and we also reported the first fully quantitative study that compared this method with the well-established in vitro permeation test (IVPT) model. To further explore the potential of quantitative CRS in assessing topical delivery, the present work investigated the effects of commonly used excipients on the percutaneous absorption of a model drug, ibuprofen (IBU). Permeation of IBU and selected solvents following finite dose applications to human skin was determined in vitro and in vivo by Franz diffusion studies and quantitative CRS, respectively. The solvents used were propylene glycol (PG), dipropylene glycol (DPG), tripropylene glycol (TPG), and polyethylene glycol 300 (PEG 300). Overall, the cumulative amounts of IBU that permeated at 24 h in vitro were similar for PG, DPG, and TPG (p > 0.05). These three vehicles outperformed PEG 300 (p < 0.05) in terms of drug delivery. Concerning the vehicles, the rank order for in vitro skin permeation was DPG ≥ PG > TPG, while PEG 300 did not permeate the skin. A linear relationship between maximum vehicle and IBU flux in vitro was found, with a correlation coefficient (R2) of 0.95. When comparing in vitro with in vivo data, a positive in vitro–in vivo (IVIV) correlation between the cumulative permeation of IBU in vitro and the total amount of IBU that penetrated the stratum corneum (SC) in vivo was observed, with a Pearson correlation coefficient (R2) of 0.90. A strong IVIV correlation, R2 = 0.82, was found following the linear regression of the cumulative number of solvents permeated in vitro and the corresponding skin uptake in vivo measured with CRS. This is the first study to correlate in vivo permeation of solvents measured by CRS with data obtained by in vitro diffusion studies. The IVIV correlations suggest that CRS is a powerful tool for profiling drug and vehicle delivery from dermal formulations. Future studies will examine additional excipients with varying physicochemical properties. Ultimately, these findings are expected to lead to new approaches for the design, evaluation, and optimization of formulations that target actives to and through the skin.

22 February 2024 in Pharmaceutics
Verified
Journal Article
Open access
PDF file
CNClaudio Nico
Claudio Nico
TSTom Bakker Schut
Tom Bakker Schut
PCPeter Caspers
Peter Caspers
GPGerwin Puppels
Gerwin Puppels
We have developed a method to determine the limit of detection (LoD) for quantitative measurement of exogenous analytes in the outer layer of the human skin by in vivo confocal Raman spectroscopy. The method is in accordance with the guidelines of the International Council for Harmonisation of Technical Requirements for Pharmaceuticals for Human Use that have been adopted by regulatory authorities such as the American Food and Drug Administration and the European Medicines Agency. The method can be applied in silico so that the limit of detection can be assessed before starting a skin penetration study, for example, in areas of pharmaceutical formulation, pharmacokinetics, or toxicokinetics. This can significantly reduce the need for expensive and time-consuming feasibility studies. This paper describes the method to calculate this LoD as well as the experimental and methodological factors that can influence the calculation of the LoD.

6 October 2021 in Medical Engineering & Physics
Verified
Journal Article
Open access
YAY. Aaboubout
Y. Aaboubout
MSM.R. Nunes Soares
M.R. Nunes Soares
EBE.M. Barroso
E.M. Barroso
LSL.C. van der Sar
L.C. van der Sar
ABA. Bocharnikov
A. Bocharnikov
GPGerwin Puppels
Gerwin Puppels
This study reports on the effects of insertion velocity, needle tip geometry and needle diameter on tissue deformation and maximum insertion force. Moreover, the effect of multiple insertions with the same needle on the maximum insertion force is reported. The tissue deformation and maximum insertion force strongly depend on the insertion velocity and the tip geometry. No correlation was found between the outer diameter and the maximum insertion force for small needles (30G - 32G). The endurance experiments showed no remarkable difference in the maximum insertion force during 100 insertions.

19 March 2020 in Journal of Biophotonics
Verified
Journal Article
Open access
PDF file
GPGerwin Puppels
Gerwin Puppels
PCPeter Caspers
Peter Caspers
CNClaudio Nico
Claudio Nico
Click on the book chapter title to read more.