Yee Cheong Lam

Prof. Yee Cheong Lam

Nanyang Technological University, School of Mechanical and Aerospace Engineering
orcid

Research Focus & Metrics

Academic Career Length

43Years (1984-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2001 in Langmuir
Verified
Journal Article
Closed access
LLL. Li
L. Li
PTP. M. Thangamathesvaran
P. M. Thangamathesvaran
CYC. Y. Yue
C. Y. Yue
MTMichael K.C. Tam
Michael K.C. Tam
XHXiao ‘Matthew’ Hu
Xiao ‘Matthew’ Hu
Yee Cheong LamYee Cheong Lam
Yee Cheong Lam

14 August 2002 in Langmuir
Verified
Journal Article
Closed access
LLL. Li
L. Li
HSH. Shan
H. Shan
CYC. Y. Yue
C. Y. Yue
Yee Cheong LamYee Cheong Lam
Yee Cheong Lam
MTMichael K.C. Tam
Michael K.C. Tam
XHXiao ‘Matthew’ Hu
Xiao ‘Matthew’ Hu

22 August 2013 in Acta Mechanica
Verified
Journal Article
Closed access
PDF file
ZCZhaoxiang Chen
Zhaoxiang Chen
Kun ZhouKun Zhou
Kun Zhou
XLXuehong Lu
Xuehong Lu
Yee Cheong LamYee Cheong Lam
Yee Cheong Lam

28 November 2008 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
WNWee Yang Ng
Wee Yang Ng
SGShireen Goh
Shireen Goh
Yee Cheong LamYee Cheong Lam
Yee Cheong Lam
CYChun Yang
Chun Yang
IRIsabel Rodríguez
Isabel Rodríguez
This paper presents a novel approach of mixing two laminar flowing streams in microchannels. The mixer consists of a pair of electrodes disposed along a fluidic channel. By energizing the electrodes with a DC-biased (2.5 V) AC voltage (20 Vpp), an electrokinetic flow is induced with a flow profile perpendicular to that of the incoming laminar streams of liquids to be mixed. As a result, the flow lines of the incoming streams and the induced flow are forced to crossover and very efficient stirring and mixing at short mixing length can be achieved. The mixer can be operated from the AC-electroosmotic (ACEO) (σ = 1 mS/m, f = 100 kHz) to the AC-electrothermal (ACET) (σ = 500 mS/m, f = 500 kHz) flow regimes. The mixing efficiency in the ACEO regime was 92%, with a mixing length of 600 µm ( = 2 µL/min), an estimated mixing time of 69 ms and an induced ACEO flow velocity of ∼725 µm/s. The mixing efficiency in the ACET regime was 65% for a mixing length of ∼1200 µm. The mixer is efficient and suitable for mixing reagents in a fluid media from low to high conductivity as required in diverse microfluidic applications.

1 January 2005 in Polymer
Verified
Journal Article
Closed access
LJL. Jiang
L. Jiang
Yee Cheong LamYee Cheong Lam
Yee Cheong Lam
MTMichael K.C. Tam
Michael K.C. Tam
TCT.H. Chua
T.H. Chua
GSG.W. Sim
G.W. Sim
LAL.S. Ang
L.S. Ang

1 May 2018 in Nature Communications
Verified
Journal Article
Open access
PDF file
QXQirong Xiong
Qirong Xiong
CLChun Yee Lim
Chun Yee Lim
JRJinghua Ren
Jinghua Ren
JZJiajing Zhou
Jiajing Zhou
KPKanyi Pu
Kanyi Pu
HDHongwei Duan
Hongwei Duan
Microfluidic biochips hold great potential for liquid analysis in biomedical research and clinical diagnosis. However, the lack of integrated on-chip liquid mixing, bioseparation and signal transduction presents a major challenge in achieving rapid, ultrasensitive bioanalysis in simple microfluidic configurations. Here we report magnetic nanochain integrated microfluidic chip built upon the synergistic functions of the nanochains as nanoscale stir bars for rapid liquid mixing and as capturing agents for specific bioseparation. The use of magnetic nanochains enables a simple planar design of the microchip consisting of flat channels free of common built-in components, such as liquid mixers and surface-anchored sensing elements. The microfluidic assay, using surface-enhanced Raman scattering nanoprobes for signal transduction, allows for streamlined parallel analysis of multiple specimens with greatly improved assay kinetics and delivers ultrasensitive identification and quantification of a panel of cancer protein biomarkers and bacterial species in 1 μl of body fluids within 8 min.