1 June 2018 in Building and Environment
Verified
Journal Article
Closed access
HAHarald Andersson
Harald Andersson
Mathias CehlinMathias Cehlin
Mathias Cehlin
BMB. Moshfegh
B. Moshfegh

16 October 2020 in Energies
Verified
Journal Article
Open access
PDF file
HAHarald Andersson
Harald Andersson
AKAlan Kabanshi
Alan Kabanshi
Mathias CehlinMathias Cehlin
Mathias Cehlin
BMBahram Moshfegh
Bahram Moshfegh
The performance of three different confluent jets ventilation (CJV) supply devices was evaluated in a classroom environment concerning thermal comfort, indoor air quality (IAQ) and energy efficiency. The CJV supply devices have the acronyms: high-momentum confluent jets (HMCJ), low-momentum confluent jets (LMCJ) and low-momentum confluent jets modified by varying airflow direction (LMCJ-M). A mixing ventilation (MV) slot jet (SJ) supply device was used as a benchmark. Comparisons were made with identical set-up conditions in five cases with different supply temperatures (TS) (16–18 °C), airflow rates (2.2–6.3 ACH) and heat loads (17–47 W/m2). Performances were evaluated based on DR (draft rating), PMV (predicted mean vote), ACE (air change effectiveness) and heat removal effectiveness (HRE). The results show that CJV had higher HRE and IAQ than MV and LMCJ/LMCJ-M had higher ACE than HMCJ. The main effects of lower Ts were higher velocities, DR (HMCJ particularly) and HRE in the occupied zone as well as lower temperatures and PMV-values. HMCJ and LMCJ produce MV conditions at lower airflow rates (<4.2 ACH) and non-uniform conditions at higher airflow rates. LMCJ-M had 7% higher HRE than the other CJV supply devices and produced non-uniform conditions at lower airflow rates (<3.3 ACH). The non-uniform conditions resulted in LMCJ-M having the highest energy efficiency of all devices.

22 February 2022 in Energies
Verified
Journal Article
Open access
PDF file
HAHarald Andersson
Harald Andersson
Mathias CehlinMathias Cehlin
Mathias Cehlin
BMBahram Moshfegh
Bahram Moshfegh
In this study, confluent jets ventilation (CJV) supply devices with three different nozzle arrays (1 × 19, 2 × 19, 3 × 19) were investigated both numerically and experimentally at two different airflow and supply air temperature set-ups. The performance of the CJV supply devices was investigated concerning thermal comfort, indoor air quality (IAQ), and heat removal effectiveness in a conference room environment. A comparison between the experimental and numerical results showed that the  ϑ2¯−f model had the best agreement out of the investigated turbulence models. The numerical results showed that the size of the array had a great impact both on near-field development and on the conditions in the occupied zone. A larger array with multiple rows and a lower momentum conserved the inlet temperature and the mean age of the air better than a single-row array with a higher momentum. A larger array with multiple rows had a higher IAQ and a greater heat removal effectiveness in the occupied zone because the larger array conserved the mean age of air better and the buoyancy driven flow was slightly better at removing the heat. Because of the lower inlet velocities, they also had lower velocities at ankle level, which decreased the risk of draft and thermal discomfort.

19 January 2024 in International Journal of Ventilation
Verified
Journal Article
Open access
HAHarald Andersson
Harald Andersson
MCMathias Cehlin
Mathias Cehlin
BMBahram Moshfegh
Bahram Moshfegh