The fluctuation-noise method for proton-exchange membrane fuel cell diagnostic is suggested. It has been experimentally confirmed that fuel cell technical state has influence on the characteristics of electrical fluctuations and the diagnostic features of fuel cell fluctuation characteristics could be assumed as the basis for fuel cell technical state diagnostics systems development. It has been shown that an incorrect fuel cell water balance can be detected by means of electrical fluctuation parameter measurement.
This work considers the possibility of applying electrochemical noise analysis to fuel cell diagnostics. Theoretical hypothesis and experimental result have shown that spectral characteristics of electrical fluctuations depend on water management processes inside the PEMFC. It has been established that the spectrum of electrical fluctuations in low frequency range has the nature of flicker noise. The frequency ranges of 0.1-1 Hz convenient for single cell as well as for stack diagnostics are revealed. The results show that the proposed approach can be considered as an e ffective tool to diagnose of fuel cells, namely allowing for prediction of drying and flooding.