Peter Ammann

Prof. Dr. Peter Ammann


Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2003 in JACC
Verified
Journal Article
Closed access
PAPeter Ammann
Peter Ammann
MMMarco Maggiorini
Marco Maggiorini
OBOsmund Bertel
Osmund Bertel
EHEdgar Haenseler
Edgar Haenseler
HJHelen I Joller-Jemelka
Helen I Joller-Jemelka
TFThomas Fehr
Thomas Fehr

29 April 2004 in BMJ
Verified
Journal Article
Closed access
PDF file
PAPeter Ammann
Peter Ammann
MPMatthias Pfisterer
Matthias Pfisterer
TFThomas Fehr
Thomas Fehr
HRHans Rickli
Hans Rickli
References ↵ Braunwald E, Antman EM, Beasley JW, Califf RM, Cheitlin MD, Hochman JS, et al . ACC/AHA guidelines for the management of patients with unstable angina and non-ST-segment elevation myocardial infarction: executive summary and recommendations. A report of the American College of Cardiology/American Heart Association task force on practice guidelines (committee on the management of patients with unstable angina). Circulation 2000; 102: 1193–209. ↵ Myocardial infarction redefined—a consensus document of the Joint European Society of Cardiology/American College of Cardiology committee for the redefinition of myocardial infarction . J Am Coll Cardiol 2000; 36: 959–69. ↵ Ammann P, Fehr T, Minder EI, Gunter C, Bertel O . Elevation of troponin I in sepsis and septic shock. Intensive Care Med 2001; 27: 965–9. ↵ Heidenreich PA, Alloggiamento T, Melsop K, McDonald KM, Go AS, Hlatky MA . The prognostic value of troponin in patients with non-ST elevation acute coronary syndromes: a meta-analysis. J Am Coll Cardiol 2001; 38: 478–85. ↵ Shave R, Dawson E, Whyte G, George K, Ball D, Collinson P, et al . The cardiospecificity of the third-generation troponin T assay after exercise-induced muscle damage. Med Sci Sports Exerc 2002; 34: 651–4. ↵ Tucker JF, Collins RA, Anderson AJ, Hauser J, Kalas J, Apple FS . Early diagnostic efficiency of cardiac troponin I and Troponin T for acute myocardial infarction. Acad Emerg Med 1997; 4: 13–21. ↵ Bertinchant JP, Larue C, Pernel I, Ledermann B, Fabbro-Peray P, Beck L, et al . Release kinetics of serum cardiac troponin I in ischemic myocardial injury. Clin Biochem 1996; 29: 587–94. ↵ Christenson RH, Apple FS, Morgan DL, Alonsozana GL, Mascotti K, Olson M, et al . Cardiac troponin I measurement with the ACCESS immunoassay system: analytical and clinical performance characteristics. Clin Chem 1998; 44: 52–60. ↵ Hamm CW . New serum markers for acute myocardial infarction. N Engl J Med 1994; 331: 607–8. ↵ Brett J, Gerlach H, Nawroth P, Steinberg S, Godman G, Stern D . Tumor necrosis factor/cachectin increases permeability of endothelial cell monolayers by a mechanism involving regulatory G proteins. J Exp Med 1989; 169: 1977–91. ↵ Piper HM, Schwartz P, Spahr R, Hütter JF, Spieckermann PG . Early enzyme release from myocardial cells is not due to irreversible cell damage. J Mol Cell Cardiol 1984; 16: 385–8. ↵ McDonough JL, Arrell DK, Van Eyk JE . Troponin I degradation and covalent complex formation accompanies myocardial ischemia/reperfusion injury. Circ Res 1999; 84: 9–20.

3 February 2010 in PLOS ONE
Verified
Journal Article
Open access
PDF file
DADavid R. Altmann
David R. Altmann
WKWolfgang Korte
Wolfgang Korte
MMMicha T. Maeder
Micha T. Maeder
TFThomas Fehr
Thomas Fehr
PHPhilipp Haager
Philipp Haager
PAPeter Ammann
Peter Ammann
Elevated cardiac troponin I (cTnI) is frequently observed in patients with severe sepsis and septic shock. However, the mechanisms underlying cTnI release in these patients are still unknown. To date no data regarding coagulation disturbances as a possible mechanism for cTnI release during sepsis are available. Consecutive patients with systemic inflammatory response syndrome (SIRS), sepsis or septic shock without evidence of an acute coronary syndrome were analyzed. Coagulation parameters (clotting time (CT), clot formation time (CFT), maximum clot firmness (MCF), α-angle) were assessed in native whole blood samples, and using specific activators to evaluate the extrinsic and intrinsic as well as the fibrin component of the coagulation pathway with the use of rotational thrombelastometry (ROTEM). Thirty-eight patients were included and 22 (58%) were cTnI-positive. Baseline characteristics between TnI-positive and -negative patients were similar. The CT, CFT, MCF and the α-angle were similar between the groups with trends towards shorter CT in the extrinsic and fibrin activation. We found no differences in coagulation parameters analyzed with rotational thrombelastometry between cTnI-positive and -negative patients with SIRS, severe sepsis, and septic shock. These findings suggest that pathophysiological mechanisms other than thrombus-associated myocardial damage might play a major role, including reversible myocardial membrane leakage and/or cytokine mediated apoptosis in these patients.

21 April 2003 in Catheterization and Cardiovascular Interventions
Verified
Journal Article
Closed access
PDF file
PAPeter Ammann
Peter Ammann
HRHans P. Brunner‐La Rocca
Hans P. Brunner‐La Rocca
WAWalter Angehrn
Walter Angehrn
HRHans Roelli
Hans Roelli
MSMarkus Sagmeister
Markus Sagmeister
HRHans Rickli
Hans Rickli

21 June 2005 in Annals of Internal Medicine
Verified
Journal Article
Closed access
PDF file
PAPeter Ammann
Peter Ammann
CSChristian Sticherling
Christian Sticherling
DKDietrich Kalusche
Dietrich Kalusche
JEJens Eckstein
Jens Eckstein
ABAlain Bernheim
Alain Bernheim
SOStefan Osswald
Stefan Osswald
Loss of left ventricular capture in patients with cardiac resynchronization devices may account for worsening heart failure and can be difficult to diagnose without a programmer. To determine whether distinct morphologic changes on the surface electrocardiogram indicate loss of left ventricular capture. After analysis of the R–S spike ratio in the 12-lead electrocardiogram during right ventricular and biventricular pacing in 10 patients, an algorithm to detect loss of left ventricular capture was developed. University hospital. 54 patients with a cardiac resynchronization device and underlying left bundle-branch block. Leads V1 and I of a 12-lead electrocardiogram were assessed after biventricular pacing was confirmed and after the device was programmed to right ventricular pacing only (simulating loss of left ventricular capture). The sensitivity of the algorithm to correctly identify loss of left ventricular capture was 94% (95% CI, 88.2% to 97.7%), and the specificity was 93% (CI, 86.3% to 95.8%). The likelihood ratio of a positive test result was 12.8 (CI, 6.443 to 23.310), and the likelihood ratio of a negative test result was 0.06 (CI, 0.024 to 0.137). The algorithm was tested in patients in whom the right ventricular electrode was placed in the apex of the right ventricle only. Presence of biventricular capture—the prerequisite for successful cardiac resynchronization therapy—and loss of left ventricular capture can be accurately detected by an algorithm based on analysis of the R–S ratio on leads V1 and I of the surface electrocardiogram.

16 February 2005 in Journal of Cardiovascular Electrophysiology
Verified
Journal Article
Closed access
PDF file
CBChristian Binggeli
Christian Binggeli
HRHans Rickli
Hans Rickli
PAPeter Ammann
Peter Ammann
CBCorinna Brunckhorst
Corinna Brunckhorst
UHUrs Hufschmid
Urs Hufschmid
FDFirat Duru
Firat Duru