Michal Ženíšek

Dr. Michal Ženíšek

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 October 2020 in Sustainability
Verified
Journal Article
Open access
PDF file
MŽMichal Ženíšek
Michal Ženíšek
JPJan Pešta
Jan Pešta
MTMartin Tipka
Martin Tipka
Vladimír KočíVladimír Kočí
Vladimír Kočí
Petr HajekPetr Hajek
Petr Hajek
Reinforced concrete (RC) structures represent one of the most widespread building systems around the world. This paper deals with the optimization of load-bearing RC structures in terms of cost and environmental impact. The results of the optimization are the dimensions and reinforcement of structural elements for which the total construction costs and environmental impacts are the lowest. Six variants of RC building structures were designed and analyzed in a case study. The construction cost was evaluated on the basis of the national pricing system. The life cycle assessment (LCA) characterization model according to the ReCiPe methodology version 1.08 was used to assess environmental impacts. The main motivation of this article was to show the possibilities of the multi-criteria optimization of a load-bearing structure, not only from a structural point of view but also from economic and environmental points of view. The presented conclusions correspond to this specific construction of the RC structure used in the case study and may not be generalized. Nevertheless, they point to certain trends and patterns that can also be used in the design of other reinforced concrete structures. The method used in this case study could be applied to the analysis of other structures using specific datasets for cost and environmental impact evaluation.

21 October 2014 in Advanced Materials Research
Verified
Journal Article
Closed access
PDF file
TVTomáš Vlach
Tomáš Vlach
LLLenka Laiblová
Lenka Laiblová
ACAlexandru Chira
Alexandru Chira
MNMagdaléna Novotná
Magdaléna Novotná
CFCtislav Fiala
Ctislav Fiala
Petr HajekPetr Hajek
Petr Hajek
Currently, high performance concrete (HPC) is becoming more and more popular mainly because of its great mechanical parameters. As in the case of ordinary power concrete (OPC) it is necessary to improve the load bearing capacity with using of reinforcement. The present age calls for using of very thin structures for reasons of both environmental parameters and visual quality. Based on this fact, reinforcement start to use durable composite materials, such as technical textiles made of them. Element of HPC with this type of reinforcement is called textile reinforced high performance concrete (TRHPC). It is impossible to use the traditional approach for usually used steel reinforcement if we want to design these extra-thin structures. Modeled structures are very sensitive for input parameters and the development of standards for TRC material lags. The present study is focused on the different method of approach for the determination of tensile modulus of composite reinforcement. Three used methods are compared with each other using numerical analysis of four point bending test of façade element for one type of used reinforcement. Curves from numerical analysis are finally compared with the curve from real experiment and based on this the final evaluation is generated.

1 June 2015 in Advanced Materials Research
Verified
Journal Article
Closed access
PDF file
MŽMichal Ženíšek
Michal Ženíšek
TVTomáš Vlach
Tomáš Vlach
LLLenka Laiblová
Lenka Laiblová
A low water-cement ratio is one of the main characteristics of high performance concrete thanks to high strength of concrete is achieved. However, it leads to deterioration of the rheological properties and therefore it is necessary to use a plasticizing admixtures. Other options to influence workability are introduced in this article. There is studied the correct selection of cement, the temperature of water, the particle size distribution of aggregates (packing density) and the use of ground granulated blast furnace slag (GGBS). The performed experiments show a greater or lesser influence all studied options on the workability. Therefore this options is appropriate to keep in mind during mix design of high performance concrete.

1 June 2019 in IOP Conference Series: Earth and Environmental Science
Verified
Conference Paper
Open access
PDF file
MŽMichal Ženíšek
Michal Ženíšek
PHP Hájek
P Hájek
The volume of CO2 emissions (and other greenhouse gases) has been rising almost continuously for several decades. Concrete is the most used man-made material in the world, thus the construction of reinforced concrete (RC) structures is associated with high environmental impact, mainly due to the consumption of cement as binder for concrete and steel as reinforcement. This article analyses the available options for the design of RC structure to reduce embodied CO2 emissions. The main part of the article is a case study demonstrating optimization of the load-bearing structure of multi-storey building. Emphasis was placed on achieving the optimal variant in terms of CO2 emissions, while maintaining a comparable cost of the construction. The results of this study show that in this particular case the use of concrete with a lower strength brings lower environmental impact than of concrete with higher strength. The reason is that the production of lower strength concrete allows the use of cements with a lower clinker content which is decisive for CO2 emissions. However, the use of concrete with higher strength allows more subtle structural members with lower content of concrete and potentially with higher durability.

24 October 2025 in Buildings
Verified
Journal Article
Open access
PDF file
LŘLuboš Řehounek
Luboš Řehounek
MŽMichal Ženíšek
Michal Ženíšek
In regions where seismic loads pose a significant danger to the structural stability of buildings, developing sustainable solutions for increasing the ductility of structural members is of great importance. One of the contemporary, emerging approaches is to use the greater confinement of concrete using multispiral reinforcement. A numerical model of two variants of Multispiral-Reinforced Concrete Columns (MRCCs) that differ in their axial loads using FEA was developed and validated. A non-linear combined fracture-plasticity concrete model with the crack band approach and an embedded reinforced model with bond slip were used. The main finding is that higher axial loads do not significantly increase the stiffness response, but reduce ductility (achieved drift). The achieved force agreement between the simulation and the experiment is within 2% at the peak and within 24% at the largest column drift in the post-peak region. For the purpose of rapid prototyping, a plugin that enables the user to quickly change various properties of MRCC geometry using an automated approach instead of modeling individual variants from zero is proposed. This overall approach was developed to both save on user time spent modeling and on the great costs that involve manufacturing and testing of real-scale specimens.