kaixuan hu

Mr. kaixuan hu

School of Civil Engineering, Hefei University of Technology

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 April 2021 in Processes
Verified
Journal Article
Open access
PDF file
Jun LiuJun Liu
Jun Liu
Yong SunYong Sun
Yong Sun
SYSanjiang Yv
Sanjiang Yv
JWJiaquan Wang
Jiaquan Wang
kaixuan hukaixuan hu
kaixuan hu
Industrial wastewater contains high concentrations of inorganic salts and organic matter. This experiment studied a system for treating wastewater containing high concentrations of inorganic salts and organic matter. The setup consists of a closed-cycle humidification and dehumidification system and a filter press. Chemical wastewater was used as the treatment solution, and the treatment performance of the system was tested and analyzed. The system effectively reduced the chemical oxygen demand (COD), electric conductivity (EC), total nitrogen (TN), and ammonia nitrogen (NH4-N) in the wastewater and, at the same time, dehydrated sludge was obtained through a filter press. The system maintains a stable removal rate of each index (COD, EC, TN, and NH4-N) in wastewater and can remove inorganic salts and organic matter from wastewater. The system can successfully treat industrial wastewater containing high concentrations of inorganic salts and organic matter.

10 September 2020 in Processes
Verified
Journal Article
Open access
PDF file
Jun LiuJun Liu
Jun Liu
Yong SunYong Sun
Yong Sun
SYSanjiang Yv
Sanjiang Yv
JWJiaquan Wang
Jiaquan Wang
kaixuan hukaixuan hu
kaixuan hu
The use of seawater desalination technology to solve water shortages in energy- and resource-scarce regions has attracted widespread attention worldwide. In this paper, the performance of a closed-cycle humidification–dehumidification desalination system with a heat pump was experimentally investigated. The system is a closed-cycle system, which includes humidifiers, a heat pump, dehumidifiers, and an air heat exchanger. The heat pump is used by the system to carry energy. The effects of different parameters on the system performance were studied. Scale and economic analyses of the system were conducted to explore the application prospects of the system. The maximum gained output ratio of the system was 4.82. The maximum freshwater production was 960 kg/h, and the cost per kilogram of freshwater was USD 0.03, which are more considerable compared with other systems. This system provides an effective way to save energy in remote areas with energy shortages and freshwater resource shortages.