This paper reports the application of RC dynamic models for assessing thermal performance of buildings from in-situ tests (obtaining the U value for the walls, and the UA value and gA value for the whole buildings). The following aspects which are relevant to this approach have been systematically analyzed: The effect of the solar radiation on the heat flux through the opaque walls versus the performance of the models including this effect, the optimum number of nodes required to represent the thermal systems, the assignment of inputs and outputs and the length of the test period. Additionally, several options modelling relevant effects using unmeasured variables were studied to evaluate the feasibility to reduce the cost and intrusiveness of the measurement devices required to obtain accurate results. Data series recorded under different experimental conditions were considered to analyze the robustness and validity of the results. The performance of the models for each of these different test conditions is discussed. The uncertainties estimated using the described method for the U values of the opaque walls, and the UA and gA values of the whole building, are, respectively, 2.8%, 4.2% and 2.3%. The feasibility to model relevant effects using unmeasured variables has been demonstrated. A simplified and well-known building has been used as a case study, reinforcing and complementing the validation criteria.


2 December 2022 in Sensors
Verified
Journal Article
Open access
PDF file
CLCarmen Serrano Lapuente
Carmen Serrano Lapuente
Héctor Herrada FernándezHéctor Herrada Fernández
Héctor Herrada Fernández
MJMaría José Jiménez
María José Jiménez
MSM. Nuria Sánchez
M. Nuria Sánchez
The measurement of the CO2 concentration has a wide range of applications. Traditionally, it has been used to assess air quality, with other applications linked to the experimental assessment of occupancy patterns and air renewal rates. More recently, the worldwide dissemination of COVID-19 establishing a relationship between infection risk and the mean CO2 level has abruptly led to the measurement of the CO2 concentration in order to limit the spread of this respiratory disease in the indoor environment. Therefore, the extensive application of this measurement outside of traditional air quality assessment requires an in-depth analysis of the suitability of these sensors for such modern applications. This paper discusses the performance of an array of commercial wall-mounted CO2 sensors, focusing on their application to obtain occupancy patterns and air renovation rates. This study is supported by several long-term test campaigns conducted in an in-use office building located in south-eastern Spain. The results show a spread of 19–101 ppm, with a drift of 28 ppm over 5 years, an offset of 2–301 ppm and fluctuations up to 80 ppm in instantaneous measurements not related to concentration changes. It is proposed that values averaged over 30 min, using a suitable reference value, be used to avoid erroneous results when calibration is not feasible.