Jihad Awad

Prof. Dr. Jihad Awad

Ajman University, Ajman, United Arab Emirates
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 August 2021 in Buildings
Verified
Journal Article
Open access
PDF file
Jihad AwadJihad Awad
Jihad Awad
Chuloh JungChuloh Jung
Chuloh Jung
The Public Health and Safety Department of Dubai Municipality had evaluated the indoor air quality in public buildings in 2013, then established the IAQ (Indoor Air Quality) regulation. Even though IAQ in public building is in control, indoor air pollution in new and renovated housing is still very problematic. The objective of this paper is to measure the indoor air quality of the residential unit in an apartment after renovation to evaluate the actual condition and to analyze the influential factors. As a methodology, field measurements, resident interviews, and observations were conducted for 20 residential units to investigate basic information, renovation contents, ventilation characteristics, and SBS (Sick Building Syndrome) symptoms. The results showed that renovation related to the indoor air quality was the replacement of finishing materials. It was statistically proven that the average CO2 for each house was 683–2309.4 ppm, and 15 houses exceeded the WHO IAQ standards. TVOC had an average concentration of 0–3.0 ppm per house, exceeding the standard in 10 houses. Formaldehyde (CH2O) had an average concentration of 0–1.02 ppm per house, exceeding the WHO IAQ standard (0.1 ppm) in 12 houses. However, even though the indoor air quality was polluted, the residents were hardly aware of it based on subjective response survey. As the amount of renovation increases, the concentration of formaldehyde (CH2O) increases significantly, and excessive renovation should be avoided. This study will serve as a basic dataset to suggest that the new IAQ regulation not be compulsory for residents; rather, they must induce contractors with stipulation to maintain IAQ during and after renovation.

10 June 2021 in Buildings
Verified
Journal Article
Open access
PDF file
Chuloh JungChuloh Jung
Chuloh Jung
Jihad AwadJihad Awad
Jihad Awad
Due to unprecedented urbanization, UAE had built many new residential projects with poor choices of material and ventilation. This social phenomenon is leading UAE to Sick Building Syndrome (SBS) faster than any other countries. The Dubai Municipality regulates the indoor air quality with strict stipulation, but the detailed regulations are still insufficient. The objective of this paper is to measure the indoor air quality of new residential projects in Dubai to suggest the improvement of the regulations for indoor air quality. As a methodology, a field survey was conducted to investigate the status of indoor air pollution in residential buildings. Based on the field survey data, lab experiments for building materials were conducted and a computer simulation on radon gas was conducted. The result had shown that radon gas was mainly detected in new townhouses and labor camp houses, and its concentration was found to exceed the standard. Volatile organic compounds (VOCs) and formaldehyde (CH2O) were mainly detected in showhouses and new townhouses, and the concentration distribution was about 10 times higher than that of outdoors. It was proven that emission concentration of radon gas from various building materials were detected, and the order was red clay, gypsum board, and concrete. Volatile organic compounds (VOCs) are mainly detected in oil paints and PVC floor and the radiation amount of all pollutants increased with temperature increase. In computer simulation, it was found that a new townhouse needs a grace period from 20 days to 6 months to lower the radon gas concentration by 2 pCi/L. This study will serve as a basic data to establish more detailed regulation for the building materials and improve the IAQ standards in Dubai.

4 July 2021 in Buildings
Verified
Journal Article
Open access
PDF file
Chuloh JungChuloh Jung
Chuloh Jung
Jihad AwadJihad Awad
Jihad Awad
The objective of this paper is to investigate the effect of improving indoor air quality with indoor plants. As a methodology, two target classrooms with the same size (120.64 m2) and 32 students per room were selected. Then, 48 areca palm pots (average leaf area of 300 cm2/pot) were placed, and the plant density was 14.68% of the floor area. Subjective assessment for general questions, learning motivation, perceived air quality, and SBS symptoms was conducted at 5 min after the class started and 5 min before the class ended. The results showed that the CO2 concentration by respiration of the students (average of 1873 ppm) exceeded the regulatory standard (1000 ppm), but the students did not recognize the indoor CO2 concentration. The increase in CO2 concentration in the classroom was lower in the case with plant placement (624 ppm) compared with the case without plant placement (about 1205 ppm). It was statistically proven that the CO2 concentration by respiration could be reduced by 50% if the indoor plant leaf area density were maintained at about 14.68% of the floor area. In the case with plant placement, the students perceived the indoor air quality to be 40% fresher and showed a 140% higher acceptability. Moreover, the complaining of SBS symptoms was improved by 108%, and the students’ perception that it was better to focus on learning increased by about 120%. As the awareness of sustainability increases, indoor plants will be more actively placed in the United Arab Emirates. Indoor plants not only provide a visual green effect to improve human comfort but also purify indoor air pollutants.

5 September 2022 in Sustainability
Verified
Journal Article
Open access
PDF file
ACAfaq Hyder Chohan
Afaq Hyder Chohan
Jihad AwadJihad Awad
Jihad Awad
This review study circumscribes wind catchers as vernacular zero-energy systems of passive ventilation. The research reviews various types of wind catchers and analyses their design, effectiveness and utility in building design. Furthermore, the study documented some of the technological transformations of wind catchers and their adaptation (functional and symbolic) in various regions. In this context, the complex design data of various wind catchers were appraised, and adaptable design data is compiled in “Geographical and Regional Influences on Wind Catcher Design “ and “Performance Evaluation of Wind Catchers” of study. The design analysis uncovered interesting facts about the effectiveness of various types of wind catchers; for example, a wind catcher with one side could be employed only as a wind scoop, whereas a multi-sided wind catcher can work simultaneously as a wind scoop and a heat sink (exhaust). The study also revealed that, in the near past, wind catchers were extensively used for ventilation. However, in modern times they are being adapted as an element of urban and architectural (identity) rather than a functional element. Finally, the end results of this study present candid suggestions for using wind catchers in modern buildings and chalks out blueprints (design guidelines) to adapt wind catchers. Towards the adaptation of wind catchers in modern buildings, this study has worked out 14 key design modifications in different types of wind catcher. Most of these findings are related to improving wind intake, preventing dust and rain penetration, the size of a wind catcher’s opening and shaft.

5 November 2021 in Designs
Verified
Journal Article
Open access
PDF file
MAMohammad S. Arar
Mohammad S. Arar
Chuloh JungChuloh Jung
Chuloh Jung
Jihad AwadJihad Awad
Jihad Awad
ACAfaq Hyder Chohan
Afaq Hyder Chohan
The elderly are the most predicted users for smart home technology in the United Arab Emirates and the population over 65 is expected to increase to 24.3% by 2030. Despite the rapid development of smart home technology, research has been mainly focused on technology development. To encourage conservative elderly users, however, smart home technology should be implemented for UAE elderly users to accept and integrate it into their daily lives. The objective of this paper is to analyze the preferences and needs of smart home technologies to understand the behaviors of UAE elderly users, and the factors affecting the acceptance of technology. As a methodology, a survey and interview were conducted for 110 people in their 40s and 60s and a total of 105 valid survey responses were collected and used as data for frequency, mean, cross-analysis, independent sample t-test, one-way variance analysis, and multiple regression analysis with IBM SPSS statistics 27. The results showed that 67.0% of UAE elderly users have chronic diseases such as high blood pressure (16.2%), heart disease (3.8%), diabetes (32.4%), or arthritis (10.5%). Therefore, smart home technology for health management is inevitable to improve overall lifestyles. It was statistically proven that UAE elderly users want automatic fall detection in the living room (39.0%) and bedroom (25.7%). Lifestyle monitoring in living room (44.7%) and bedroom (18.1%); the elderly preferred living room most for daily life assistance (36.2%), environmental control (50.5%), health and biometric monitoring (49.5%), and video conferencing (82.9%). In the case of sensors, elderly preferred the switch at the entrance (36.2%), and motion detecting sensors (42.9%), video cameras (56.2%), and voice recognition (50.5%) sensors in the living room. However, UAE elderly users do not think smart home technology can protect their privacy. It is found that age group and computer technology affinity are the most influential variables and UAE elderly users have an anxiety about technology, which influenced the acceptance of smart home technology.

1 September 2022 in Heritage
Verified
Journal Article
Open access
PDF file
Jihad AwadJihad Awad
Jihad Awad
MAMohammad S. Arar
Mohammad S. Arar
Chuloh JungChuloh Jung
Chuloh Jung
BBBouzid BOUDIAF
Bouzid BOUDIAF
This study investigates the tourism-oriented heritage districts in the United Arab Emirates (UAE) and explores a new approach to fostering heritage tourism. This is envisaged through conducting a post-occupancy evaluation (POE) to detect the characteristics of the tourism-oriented heritage districts from the residents and tourists. The systematic evaluation of opinions is based on indicators developed by UNESCO and ICOMOS international principles. According to the survey results, it is found that Dubai’s approach was successful at reuniting people with their history via modern materials in the restoration works. This has preserved the heritage value and increased their culture and national identity. The social goal to reconnect residents to their cultural history has been realized despite the inconsistencies compared to the specification of the World Heritage Convention, which requires technical authenticity and integrity. People perceived the identities of tourism-oriented heritage districts in Dubai, Sharjah, and Ajman differently. Based on the POE survey, the Shindagha area and Al Fahidi Historical Area in Dubai were perceived as traditional destinations for tourist attractions. The Heart of Sharjah area was perceived as cultural and educational tourism, and the Ajman Heritage District area was perceived as community tourism.