Background: Coffee is a major dietary source of polyphenols. Previous research found that coffee had a protective effect on periodontal disease. In this study, we aimed to investigate whether coffee extract and its primary phenolic acid, chlorogenic acid, affect the growth and protease activity of a periodontopathogen Porphyromonas gingivalis (P. gingivalis). Methods: Coffee extract and chlorogenic acid were prepared by a two-fold serial dilution. The turbid metric test and plate count method were used to examine the inhibitory effects of chlorogenic acid on P. gingivalis. The time-kill assay was used to measure changes in the viability of P. gingivalis after exposure to chlorogenic acid for 0–24 h. The protease activity of P. gingivalis was analyzed using the optical density of a chromogenic substrate. Results: As a result, the minimum inhibitory concentration (MIC) of chlorogenic acid was 4 mg/mL, and the minimum bactericidal concentration was 16 mg/mL. Chlorogenic acid at concentrations above MIC resulted in a longer-lasting inhibitory effect on P. gingivalis viability and significantly reduced associated protease activity. The coffee extract showed antibacterial activity as observed by the disk diffusion test, whereas these inhibitory effects were not affected by different roast degrees of coffee. Conclusions: Collectively, our novel findings indicate that chlorogenic acid not only has antimicrobial activity but also reduced the protease activity of P. gingivalis. In addition, coffee extract inhibits the proliferation of P. gingivalis, which may partly be attributed to the effect of chlorogenic acid.
The design of the connectors and implant abutments could affect the stress distribution of the tooth-implant supported prosthesis (TISP) entire system after loading. Therefore, the purpose of this study was to investigate the stress distribution of the TISP in different connectors and different implant abutments after loading. The TISP design used in this study was divided into six models. R1, R2 and R3 represented the tooth and the one-piece, two-piece and three-piece abutment implant system connected by a rigid connector, respectively, while NR1, NR2 and NR3 were the corresponding tooth-abutment implant systems connected by a non-rigid connector. A vertical occlusal load of 50 N was applied at a right angle on the 6 occlusal points of the occlusal surface. As a result, regarding the maximum average stress distribution, R1 and NR1 appeared on the implant fixture, and the other four models were on the implant abutment. On the other hand, regardless of the abutment implant system, the maximum von Mises stress generated by the rigid connector was greater than the corresponding non-rigid connector in the cortical bone around implant. In addition, the three-piece abutment implant system had lower von Mises stress than the one-piece and two-piece implant systems in the cortical bone. It is concluded that by adding a flexible non-rigid connector and three-piece abutment device design to TISP, the occlusal load of the implant was dispersed, and the stress could be gradually introduced into the relatively strong implant abutment.
Improving the strength of the bonding of zirconia to composite resins remains a challenge in dental restorations. The purpose of this study was to evaluate the shear strength of the bonding of zirconia to composite resins, thereby verifying the hypothesis that as the power of the non-thermal oxygen plasma increases, the bonding strength of the plasma-treated zirconia is increased. The effects of the oxygen plasma power (100, 200, and 400 W) on the surface structure, chemical composition, and hydrophilicity of the zirconia and the strength of the bonding between zirconia and composite resin were investigated. As a result, after different plasma power treatments, the surface structure and phase composition of zirconia were not different from those of zirconia without treatment. However, the oxygen plasma treatment not only reduced carbon adsorption but also greatly increased the hydrophilicity of the zirconia surface. More importantly, the strength of the bonding between the plasma-treated zirconia and composite resin was significantly higher than that in the corresponding control group without plasma treatment. Regardless of whether the zirconia was pristine or sandblasted, the higher the plasma power, the greater the bond strength obtained. The conclusion is that the oxygen plasma treatment of zirconia can effectively improve the strength of the bonding between the zirconia and composite resin without damaging the microstructure and phase composition of the zirconia.
The bond strength and durability of highly translucent zirconia ceramics to dentin is still unclear. The purpose of this study was to investigate the effect of various surface treatments on the bond strength of self-adhesive resin cements to high-translucent zirconia crowns and dentin. A high-transparent zirconia and three self-adhesive resin cements (G-CEM LinkAce (GCL), RelyX U200 (RXU) and TotalCem (TTC)) were used. The zirconia surface was sandblasted with 50 μm alumina particles or coated with an SR Link primer, while a dentin primer (Tetric N-Bond Universal, TBU) was applied to the surface of the dentin. By using three self-adhesive resin cements, zirconia samples were bonded to the dentin surfaces of human teeth. The shear strength of the specimens was measured before and after 10,000-cycle thermocycling or 90-day aging. When using GCL to bond with the untreated dentin and various zirconia surfaces, the shear bond strength of the sandblasted (ZSB) and RS Link primer-coated (ZLK) groups was significantly higher than that of the untreated control group (Zc). However, in the case of TBU-treated dentin, the shear strength of the ZSB + LK + DTBU group was significantly higher than that of the other groups. After thermocycling and aging, the shear strength of the ZSB + LK + DTBU group using GCL and RXU cements decreased slightly, while the TTC showed no impact. The zirconia surface pretreated by sandblasting and bonding agent, which was sequentially bonded with a primer-treated dentin by using resin cements, can provide excellent shear bond strength and anti-aging performance.
The efficient rapid sintering technique has employed to dental zirconia ceramics for shortening the fabrication time of zirconia restorations. The purpose was to compare the optical properties of two generations of rapid sintered translucent zirconia using two dental colorimeters. Two generations of translucent zirconia ceramics, 3 mol% yttria-tetragonal zirconia polycrystal (3Y-TZP): Copran Zr-i Ultra-T (UT) and Cercon HT (HT), and 5 mol% yttria-tetragonal zirconia polycrystal (5Y-TZP): Cercon xt (XT), of different thicknesses (0.5, 0.8, and 1.2 mm; n = 5) underwent rapid sintering (RS) or conventional sintering (CS). The CIELAB values were measured on the white and black backgrounds, respectively, by digital colorimeters, shadepilot, DeguDent (DD) and Easyshade V, Vita (Vita). Translucency parameter (TP), color difference (ΔE), surface morphology, and surface roughness were evaluated. RS resulted in reduced lightness, except in the XT group. The chromaticity increased slightly after RS. Translucency decreased with increasing material thickness. ΔE values differed between both sintering processes but were clinically acceptable (ΔE < 5). Grain size of XT decreased after RS. RS did not affect the surface roughness. RS is a feasible method for shortening the manufacturing time of zirconia restorations. A significant difference in TP value was only in the XT group between both sintering methods as measured on DD. Color differences in rapid sintered translucent zirconia materials are imperceptible and acceptable. The specimen thickness affected more in the TP values of Vita than DD. DD has higher sensitivity to translucency and color compared with Vita.
Bridge stability under loading was influenced by bridge span with the connector and implant abutment design. Thus, the purpose of this study was to evaluate the effects of rigid and non-rigid connector designs and pontic connections of different abutment systems in the tooth-implant supported prosthesis (TISP) at different span distances on the biomechanical stress distribution of the overall system components. For comparative analysis, rigid and non-rigid bridge connections were fitted with three implant abutment systems (one-piece, two-piece and three-piece), and five implant-to-natural tooth distance configurations (12 mm, 14 mm, 16 mm, 18 mm, and 20 mm) were provided. The maximum stress between TISP components occurred at the distal side of crown margin of cement1 in rigid connector with one-piece group and the bottom of the crown3 in non-rigid connector with one-piece group, while the other groups were more concentrated at the junction between the mesial side of the implant collar and the abutment. In addition, neither the rigid nor non-rigid connector model showed that stress distribution increased proportionally with the bridge span distance. It was clinically recommended that if the implant with a shorter bridge distance of 12 mm from the natural tooth, the rigid connection of the three-piece abutment can be used as the TISP design. If the bridge distance was 18 mm longer, the non-rigid connection of the three-piece abutment could maintain the physiological movement of the natural tooth and avoid the excessive stress on the bone crest around the implant.