Jerzy Sowa

Dr. Jerzy Sowa

Warsaw Univeristy of Technology, Faculty of Building Services, Hydro- and Environmental Engineering
orcid

Research Focus & Metrics

Academic Career Length

33Years (1994-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

17 December 2020 in Energies
Verified
Journal Article
Open access
PDF file
Jerzy SowaJerzy Sowa
Jerzy Sowa
Maciej MijakowskiMaciej Mijakowski
Maciej Mijakowski
Humidity-sensitive, demand-controlled ventilation systems have been in use for many years in regions with oceanic climates. Some attempts have been made to apply this technology in Poland, which has a continental climate. This article evaluates the performance and energy consumption of such a system when applied in an eight-floor, multiunit, residential building, i.e., the virtual reference building described by the National Energy Conservation Agency (NAPE), Poland. Simulations using the computer program CONTAM were performed for the whole heating season based upon the climate in Warsaw. Besides passive stack ventilation, that served as a reference, two ventilation systems were studied: one standard and one “hybrid” system with additional roof fans. This study confirmed that the application of humidity-sensitive, demand-controlled ventilation in multiunit residential buildings in a continental climate (Dfb) led to significant energy savings (up to 11.64 kWh/m2 of primary energy). However, the operation of the system on higher floors was found to be ineffective. Ensuring consistent operation of the system on all floors required supplementary fans. The introduction of a hybrid mode reduced carbon dioxide concentrations by approximately 32% in the units located in the upper part of the building. The energetic effect in such cases depends strongly on the electricity source. In the case of the national energy grid, savings of primary energy would be relatively low, i.e., 1.07 kWh/m2, but in the case of locally produced renewable energy, the energy savings would be equal to 5.18 kWh/m2.

16 November 2020 in Preprints.org
Verified
Preprint
Open access
Jerzy SowaJerzy Sowa
Jerzy Sowa
MMMaciej Mijakowski
Maciej Mijakowski
A humidity-sensitive demand-controlled ventilation system is known for many years. It has been developed and commonly applied in regions with an oceanic climate. Some attempts were made to introduce this solution in Poland in a much severe continental climate. The article evaluates this system's performance and energy consumption applied in an 8-floor multi-unit residential building, virtual reference building described by the National Energy Conservation Agency NAPE, Poland. The simulations using the computer program CONTAM were performed for the whole hating season for Warsaw's climate. Besides passive stack ventilation that worked as a reference, two versions of humidity-sensitive demand-controlled ventilation were checked. The difference between them lies in applying the additional roof fans that convert the system to hybrid. The study confirmed that the application of demand-controlled ventilation in multi-unit residential buildings in a continental climate with warm summer (Dfb) leads to significant energy savings. However, the efforts to ensure acceptable indoor air quality require hybrid ventilation, which reduces the energy benefits. It is especially visible when primary energy use is analyzed.

1 June 2019 in IOP Conference Series: Earth and Environmental Science
Verified
Conference Paper
Open access
PDF file
Jerzy SowaJerzy Sowa
Jerzy Sowa
JHJ Hendiger
J Hendiger
MMM Maziejuk
M Maziejuk
TST Sikora
T Sikora
LOLukasz PaweL Osuchowski
Lukasz PaweL Osuchowski
HKH Kamińska
H Kamińska
Plants are the planet’s source of oxygen and the sink that removes carbon dioxide produced by burning, respiration and decay of organisms. The studies performed in small chambers indicated that plants also reduce volatile organic compounds (VOC’s). All these phenomena result in a fact that potted plants have a potential to improve IAQ and to some extent to support ventilation. Trends to “go green” increase the growing interest in the introduction of a large number of plants to offices. One should remember that work in modern offices is often associated with a high level of stress. Ornamental plants give highly significant reductions in negative mood states – reductions in anger, anxiety, depression, confusion, fatigue and stress. Leaves provide also additional sound attenuation and cooling effect due to evaporation. The paper summarises the R&D project devoted to the development of the efficient, safe and competitive systems of biofiltration based on the properties of potted plants. The paper presents examples of laboratory tests and describes first experiences from applications in two pilot office buildings.

20 January 2025 in Energy and Buildings
Verified
Journal Article
Closed access
ESEliza Szczepańska-Rosiak
Eliza Szczepańska-Rosiak
Jerzy SowaJerzy Sowa
Jerzy Sowa
KMKatarzyna Mastalerz
Katarzyna Mastalerz
Dariusz HeimDariusz Heim
Dariusz Heim

1 January 2015 in Advances in Dermatology and Allergology
Verified
Journal Article
Open access
EKEdyta Krzych-Falta
Edyta Krzych-Falta
Jerzy SowaJerzy Sowa
Jerzy Sowa
KPKarolina Prasek
Karolina Prasek
BPBarbara Piekarska
Barbara Piekarska
Adam J. SybilskiAdam J. Sybilski
Adam J. Sybilski
BSBolesław Samoliński
Bolesław Samoliński
The Allergen Challenge Chamber (ACC) is definitely a serious challenge on the one hand and an innovative solution in allergic rhinitis diagnosis on the other. The gradual validation of the chamber (according to the test protocol) will allow for standardisation, which is a process undertaken by...