Se-Jin Jeon

Prof. Se-Jin Jeon

Department of Civil Systems Engineering, Ajou University
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 August 2015 in Materials
Verified
Journal Article
Open access
PDF file
JPJong-Sup Park
Jong-Sup Park
YKYoung Jin Kim
Young Jin Kim
JCJeong-Rae Cho
Jeong-Rae Cho
SJSe-Jin Jeon
Se-Jin Jeon
The strength of Ultra-High Performance Concrete (UHPC) can be sensitively affected by the curing method used. However, in contrast to the precast plant production of UHPC where a standard high-temperature steam curing is available, an optimum curing condition is rarely realized with cast-in-place UHPC. Therefore, the trend of the compressive strength development of UHPC was experimentally investigated in this study, with a focus on early-age strength by assuming the various curing conditions anticipated on site. Concrete specimens were cured under different conditions with variables including curing temperature, delay time before the initiation of curing, duration of curing, and moisture condition. Several conditions for curing are proposed that are required when the cast-in-place UHPC should gain a specified strength at an early age. It is expected that the practical use of UHPC on construction sites can be expedited through this study.

24 September 2018 in International Journal of Concrete Structures and Materials
Verified
Journal Article
Open access
PDF file
YKYoung-Jin Kim
Young-Jin Kim
WCWon-Jong Chin
Won-Jong Chin
SJSe-Jin Jeon
Se-Jin Jeon
When ultra-high performance concrete (UHPC) is fabricated as precast members such as in a UHPC segmental bridge, the joint design between the precast members can significantly affect the overall...

5 January 2022 in International Journal of Concrete Structures and Materials
Verified
Journal Article
Open access
PDF file
SKSang-Hyun Kim
Sang-Hyun Kim
SPSung Yong Park
Sung Yong Park
SKSung Tae Kim
Sung Tae Kim
SJSe-Jin Jeon
Se-Jin Jeon
The proper estimation of prestressing force (PF) distribution is critical to ensure the safety and serviceability of prestressed concrete (PSC) structures. Although the PF distribution can be theoretically calculated based on certain predictive equations, the resulting accuracy of the theoretical PF needs to be further validated by comparison with reliable test data. Therefore, a Smart Strand with fiber optic sensors embedded in a core wire was developed and applied to a full-scale specimen and two long-span PSC girder bridges in this study. The variation in PF distribution during tensioning and anchoring was measured using the Smart Strand and was analyzed by comparison with the theoretical distribution calculated using the predictive equations for short-term prestress losses. In particular, the provisions for anchorage seating loss and elastic shortening loss were reviewed and possible improvements were proposed. A new method to estimate the amount of anchorage slip based on real PF distributions revealed that the general assumption of 3–6-mm slip falls within a reasonable range. Finally, the sensitivity of the PF distribution to a few of the variables included in the equation of the elastic shortening loss was examined. The study results confirmed that the developed Smart Strand can be used to improve the design parameters or equations in PSC structures by overcoming the drawbacks of conventional sensing technologies.

25 April 2022 in Sensors
Verified
Journal Article
Open access
PDF file
SJSe-Jin Jeon
Se-Jin Jeon
SPSung Yong Park
Sung Yong Park
SKSung Tae Kim
Sung Tae Kim
Compared to other types of sensors, fiber optic sensors have improved accuracy and durability. Recently, the Smart Strand was developed to maximize the advantages of fiber optic sensors for measuring the cable forces in prestressed concrete structures or cable-supported bridges. The Smart Strand has fiber Bragg gratings (FBGs) embedded in a core wire of the seven-wire strand. Similar to other sensors, the strain measured at an FBG is affected by temperature; therefore, the temperature effect that is not related to the mechanical strain should be compensated for or corrected in the long-term measurement subjected to temperature variation. However, a temperature compensation procedure for the FBG has yet to be established, and relevant studies have used different formulas for the compensation. Moreover, when the FBG sensors are packaged with a certain material—such as fiber reinforced polymer—for protection, it is important to consider the interaction between the FBG, packaging material, and host material during thermal behavior. Therefore, this study proposed a reasonable procedure for temperature compensation for the FBG sensors embedded in packaging material and host material. In particular, the thermal sensitivity of the Smart Strand was intensively investigated. The proposed theoretical formulas were validated through comparison with data obtained from various specimens in a temperature-controlled chamber. Finally, the procedure was applied to correct the data measured using the Smart Strands in a 20-m-long full-scale specimen for about a year, thus resulting in a realistic trend of the long-term prestressing force.

15 August 2019 in International Journal of Concrete Structures and Materials
Verified
Journal Article
Open access
PDF file
SJSe-Jin Jeon
Se-Jin Jeon
HSHo Shin
Ho Shin
SKSang-Hyun Kim
Sang-Hyun Kim
SPSung Yong Park
Sung Yong Park
JYJun-Mo Yang
Jun-Mo Yang
Although pretensioned concrete structures have increasingly been used worldwide, a number of design issues need to be addressed to further improve the structural performance. Transfer length of pretensioned members was investigated with several test variables in this study by adopting various sensing technologies including the Smart Strands with embedded fiber optic sensors. The effect of increased strength in 2360 MPa high-strength strand on the transfer length was also analyzed. Representative provisions widely used in design were compared with the test results for consistency and appropriate conservatism. The strain distribution required for the transfer length depended partly on the type and location of sensors, which suggests the challenges associated with reasonable determination of the transfer length. According to the results of the analysis, the predictive equation in ACI 318 was relatively accurate and conservative under various conditions including high-strength strands. However, the transfer lengths based on the strand strains rather than the conventional surface strains of concrete require further investigation depending on the bonding behavior between the strand and the surrounding concrete inside a member. Thus, this study also introduces a new sensing technology utilizing the Smart Strand to reliably measure the strain distribution along a strand.

13 June 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
SKSang-Hyun Kim
Sang-Hyun Kim
SPSung Yong Park
Sung Yong Park
SJSe-Jin Jeon
Se-Jin Jeon
The proper distribution of prestressing force (PF) is the basis for the design of prestressed concrete (PSC) structures. However, the PF distribution obtained by predictive equations of prestress losses has not been sufficiently validated by comparison with measured data due to the poor reliability and durability of conventional sensing technologies. Therefore, the Smart Strand with embedded fiber optic sensors was developed and applied to PSC structures to investigate the long-term characteristics of PF distribution as affected by concrete creep and shrinkage. The data measured in a 20 m-long full-scale specimen and a 60 m-long PSC girder bridge were analyzed by comparing them with the theoretical estimation obtained from several design equations. Although the long-term decreasing trend of the PF distribution was similar in the measurement and theory, the equation of Eurocode 2 for estimating the long-term prestress losses showed better agreement with the measurement than ACI 209R and ACI 423.10R did. This can be attributed to the more refined form of the predictive equation of Eurocode 2 in dealing with the time-dependency of the PF. The study results also confirmed the need to compensate for the temperature variation in the long-term monitoring to derive the actual mechanical strain related to the PF. We expect our developed Smart Strand to be applied practically in PF measurement for the reasonable safety assessment and maintenance of PSC structures by improving several of the existing drawbacks of conventional sensors.