Olivier Guenat

Prof. Dr. Olivier Guenat

ARTORG Center for Biomedical Engineering Research, University of Bern, 3012 Bern, Switzerland

Research Focus & Metrics

Academic Career Length

29Years (1998-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 December 2014 in Lab on a Chip
Verified
Journal Article
Open access
PDF file
ASAndreas O. Stucki
Andreas O. Stucki
JSJanick D. Stucki
Janick D. Stucki
SHSean R. R. Hall
Sean R. R. Hall
MFMarcel Felder
Marcel Felder
YMYves Mermoud
Yves Mermoud
OGOlivier Guenat
Olivier Guenat
We report a lung-on-a-chip array that mimics the pulmonary parenchymal environment, including the thin alveolar barrier and the three-dimensional cyclic strain induced by breathing movements. The micro-diaphragm used to stretch the alveolar barrier is inspired by the in vivo diaphragm, the main muscle responsible for inspiration. The design of this device aims not only at best reproducing the in vivo conditions found in the lung parenchyma but also at making the device robust and its handling easy. An innovative concept, based on the reversible bonding of the device, is presented that enables accurate control of the concentration of cells cultured on the membrane by easily accessing both sides of the membranes. The functionality of the alveolar barrier could be restored by co-culturing epithelial and endothelial cells that form tight monolayers on each side of a thin, porous and stretchable membrane. We showed that cyclic stretch significantly affects the permeability properties of epithelial cell layers. Furthermore, we also demonstrated that the strain influences the metabolic activity and the cytokine secretion of primary human pulmonary alveolar epithelial cells obtained from patients. These results demonstrate the potential of this device and confirm the importance of the mechanical strain induced by breathing in pulmonary research.

5 February 2021 in Communications Biology
Verified
Journal Article
Open access
PDF file
PZPauline Zamprogno
Pauline Zamprogno
SWSimon Wüthrich
Simon Wüthrich
SASven Achenbach
Sven Achenbach
GTGiuditta Thoma
Giuditta Thoma
JSJanick D. Stucki
Janick D. Stucki
OGOlivier Guenat
Olivier Guenat
The air-blood barrier with its complex architecture and dynamic environment is difficult to mimic in vitro. Lung-on-a-chips enable mimicking the breathing movements using a thin, stretchable PDMS membrane. However, they fail to reproduce the characteristic alveoli network as well as the biochemical and physical properties of the alveolar basal membrane. Here, we present a lung-on-a-chip, based on a biological, stretchable and biodegradable membrane made of collagen and elastin, that emulates an array of tiny alveoli with in vivo-like dimensions. This membrane outperforms PDMS in many ways: it does not absorb rhodamine-B, is biodegradable, is created by a simple method, and can easily be tuned to modify its thickness, composition and stiffness. The air-blood barrier is reconstituted using primary lung alveolar epithelial cells from patients and primary lung endothelial cells. Typical alveolar epithelial cell markers are expressed, while the barrier properties are preserved for up to 3 weeks.

25 September 2018 in Scientific Reports
Verified
Journal Article
Open access
PDF file
JSJanick D. Stucki
Janick D. Stucki
NHNina Hobi
Nina Hobi
AGArtur Galimov
Artur Galimov
ASAndreas O. Stucki
Andreas O. Stucki
NSNicole Schneider-Daum
Nicole Schneider-Daum
OGOlivier Guenat
Olivier Guenat
Organs-on-chips have the potential to improve drug development efficiency and decrease the need for animal testing. For the successful integration of these devices in research and industry, they must reproducein vivocontexts as closely as possible and be easy to use. Here, we describe a ‘breathing’ lung-on-chip array equipped with a passive medium exchange mechanism that provide anin vivo-like environment to primary human lung alveolar cells (hAEpCs) and primary lung endothelial cells. This configuration allows the preservation of the phenotype and the function of hAEpCs for several days, the conservation of the epithelial barrier functionality, while enabling simple sampling of the supernatant from the basal chamber. In addition, the chip design increases experimental throughput and enables trans-epithelial electrical resistance measurements using standard equipment. Biological validation revealed that human primary alveolar type I (ATI) and type II-like (ATII) epithelial cells could be successfully cultured on the chip over multiple days. Moreover, the effect of the physiological cyclic strain showed that the epithelial barrier permeability was significantly affected. Long-term co-culture of primary human lung epithelial and endothelial cells demonstrated the potential of the lung-on-chip array for reproducible cell culture under physiological conditions. Thus, this breathing lung-on-chip array, in combination with patients’ primary ATI, ATII, and lung endothelial cells, has the potential to become a valuable tool for lung research, drug discovery and precision medicine.

1 July 2005 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
LBL. Berdondini
L. Berdondini
PWP.D. van der Wal
P.D. van der Wal
OGOlivier Guenat
Olivier Guenat
NRN.F. de Rooij
N.F. de Rooij
MKM. Koudelka-Hep
M. Koudelka-Hep
SRS. Rohr
S. Rohr

2 June 2015 in Lab on a Chip
Verified
Journal Article
Open access
PDF file
JRJanine Ruppen
Janine Ruppen
FWFranziska D. Wildhaber
Franziska D. Wildhaber
CSChristoph Strub
Christoph Strub
SHSean R. R. Hall
Sean R. R. Hall
RSRalph A Schmid
Ralph A Schmid
OGOlivier Guenat
Olivier Guenat
Cancer is responsible for millions of deaths worldwide and the variability in disease patterns calls for patient-specific treatment. Therefore, personalized treatment is expected to become a daily routine in prospective clinical tests. In addition to genetic mutation analysis, predictive chemosensitive assays using patient's cells will be carried out as a decision making tool. However, prior to their widespread application in clinics, several challenges linked to the establishment of such assays need to be addressed. To best predict the drug response in a patient, the cellular environment needs to resemble that of the tumor. Furthermore, the formation of homogeneous replicates from a scarce amount of patient's cells is essential to compare the responses under various conditions (compound and concentration). Here, we present a microfluidic device for homogeneous spheroid formation in eight replicates in a perfused microenvironment. Spheroid replicates from either a cell line or primary cells from adenocarcinoma patients were successfully created. To further mimic the tumor microenvironment, spheroid co-culture of primary lung cancer epithelial cells and primary pericytes were tested. A higher chemoresistance in primary co-culture spheroids compared to primary monoculture spheroids was found when both were constantly perfused with cisplatin. This result is thought to be due to the barrier created by the pericytes around the tumor spheroids. Thus, this device can be used for additional chemosensitivity assays (e.g. sequential treatment) of patient material to further approach the personalized oncology field.

6 January 2014 in Lab on a Chip
Verified
Journal Article
Open access
PDF file
JRJanine Ruppen
Janine Ruppen
LCLourdes Cortes-Dericks
Lourdes Cortes-Dericks
EMEmanuele Marconi
Emanuele Marconi
GKGolnaz Karoubi
Golnaz Karoubi
RSRalph A Schmid
Ralph A Schmid
OGOlivier Guenat
Olivier Guenat
This study reports on a microfluidic platform on which single multicellular spheroids from malignant pleural mesothelioma (MPM), an aggressive tumor with poor prognosis, can be loaded, trapped and tested for chemotherapeutic drug response.