In order to reduce the loosening of dental implants, surface modification with hydroxyapatite (HA) coating has shown promising results. Therefore, in this present study, the sol-gel technique has been employed to form a tantalum and strontium ion-doped hybrid HA layer coating onto the titanium (Ti)-alloy substrate. In this study, the surface modification was completed by using 3% tantalum pent oxide (Ta2O5), 3% strontium (Sr), and a combination of 1.5% Ta2O5 and 1.5% Sr as additives, along with HA gel by spin coating technique. These additives played a prominent role in producing a porous structure layer coating and further cell growth. The MG63 cell culture assay results indicated that due to the incorporation of strontium ions along with tantalum embedded in HA, cell proliferation increased significantly after a 48 h study. Therefore, the present results, including microstructure, crystal structure, binding energy, and cell proliferation, showed that the additives 1.5% Ta2O5 and 1.5% Sr embedded in HA on the Ti–substrate had an optimized porous coating structure, which will enhance bone in-growth in surface-modified Ti-implants. This material had a proper porous morphology with a roughness profile, which may be suitable for tissue in-growth between a surface-modified textured implant and bone interface and could be applicable for dental implants.
Dental implants are used as a traditional technique to replace missing teeth. In the longterm evaluation of dental implants, the stability and durability of the implant-bone interface are crucial. Furthermore, the success of dental implants depends on several factors, such as osseointegration, implant geometry and surface topography. The aim of the study was to investigate the effects of coating materials on dental implants by altering several parameters, including the material used, the coating thickness, and different combinations of the cortical and cancellous bones. The coating materials used were hydroxyapatite (HAP), monticellite (MTC) and titanium nitride (TiN). The coating thickness was varied as 50 μm, 100 μm, 150 μm, and 200 μm. Five different bone combinations were used for the proposed finite element model. An axial compressive load of 150 N was applied. The FEA showed that the HAP coating material had a significant effect on minimizing the induced stress concentration for all 5 bone combinations. However, the MTC coating material had a significant effect only on 2 bone combinations (combination 2 and combination 3). Meanwhile, the TiN coating material induced higher stress values. Based on finite element analysis (FEA), it was observed that the coating thickness greatly influenced the concentration of the mechanical stress. Indeed, when the coating thickness was relatively high, the stress concentration value significantly decreased.
19 March 2021 in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
Titanium implants are commonly used in dental and other joint replacements and its several modifications have been taken place to improve the adhesion between bone and implant. Different chemical and physical modifications are generally applied to the titanium surface for improving interlocking between bone and implant materials. The present work has been investigated the shear strength stiffness and stress concentration between Representative Volume Element (RVE) model and coating material while the surface of the RVE model modified with different types of surface textures. The surface topology parameters resulted a significant increase in shear strength by 55% and 45% for straight texture and U-shape texture, respectively compared with plain surface. The stiffness reduced significantly by 18% for U-shape and but to 36% only for X-shape, when compared with plain surface. The stress concentration factor in biaxial case both dome shape and X-shape has 45%and 25% in U-shape lower than that of the plain surface. Therefore, this investigation predicted the interfacial shear strength properties generated for different surface topologies to determine the bonding behavior of the implant materials.
2 September 2024 in Frontiers in Bioengineering and Biotechnology
Introduction: This investigation delves into the mechanical behaviour of titanium dental implants, a preferred choice for tooth replacement due to their superior reliability over alternative materials. The phenomenon of implant loosening, frequently induced by masticatory activities, underscores the significance of surface modification or texturing to bolster the interaction between the implant and bone tissue. This research comprehensively examines the effects of four distinct surface texturing techniques and five varied bone quality conditions on the biomechanical performance of these implants.Methods: The scope of this study is delineated by its focus on implants of diameters 4 mm and 6 mm, with lengths measuring 9 mm and 12 mm respectively. Furthermore, the analysis incorporates the evaluation of four different coatings—hydroxyapatite, HA3TO, HA3Sr, and HA1.5TO1.5Sr—to investigate their efficacy in enhancing the osseointegration process on textured surfaces of dental implants.Results: The experimental design entails the assessment of stress distribution within the implant and its coatings, alongside the strain exerted on the surrounding cancellous bone, under the conditions of an average vertical biting force. A comparative analysis between solid implants and those subjected to surface texturing techniques has been conducted. This comparison elucidates the advantageous microstrain profiles presented by certain textured surfaces, which are deemed more conducive to optimal osseointegration.Discussion: Notably, across all examined textures, the application of hydroxyapatite (HA) and a modified HA composition (HA1.5TO1.5Sr) demonstrates significant improvements in mechanical stability, particularly in scenarios involving weak and very weak bone conditions. This study's findings contribute to the ongoing advancement in dental implant technology, emphasizing the critical role of surface texturing and coating strategies in promoting implant longevity and integration within the biomechanical environment of the human oral cavity.
The objective of project is to reduce the micromotion of novel implant under the static loads using function of uniform design for FE analysis. Integrating the features of regular implant, a new implant model has been done. Micromotion of the novel implant was obtained using static structural FE analysis. Compared to the existing International team for implantology implants, the micromotion of the novel implant model was considerably decreased by static structural analysis. Six control factors were taken for achieving minimizes the micromotion of novel dental implant system. In the present work, uniform design technique was used to create a set of finite element analysis simulation: according to the uniform design method, all FE analysis simulation; compared to the original model, the micromotion is 0.01944mm and micromotion of improved design version is 0.01244mm. The improvement rate for the micromotion is 35.02%.