Sıtkı Güner

Dr. Sıtkı Güner

Istanbul Arel University
orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 March 2022 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
AÇAlper Çiçek
Alper Çiçek
ISIbrahim Sengor
Ibrahim Sengor
Sıtkı GünerSıtkı Güner
Sıtkı Güner
FKFurkan Karakus
Furkan Karakus
AEAyse Kubra Erenoglu
Ayse Kubra Erenoglu
João P. S. CatalãoJoão P. S. Catalão
João P. S. Catalão
A significant advancement regarding the electrification of transportation has occurred in recent years due to technological developments, environmental concerns, and geopolitical issues in the energy areas all over the world. In this study, a new concept for the integration of rail-based public transportation systems with electric vehicle (EV) parking lots operated by a “park and ride” strategy is propounded, including also renewable resources based energy production. In the proposed structure, the charging power demand of the EV parking lot is supplied by different charging strategies considering the existing unused energy infrastructure capacity and the regenerative braking energy of the railway system, altogether. Here, the design of a photovoltaic (PV) based carport type renewable energy production unit is also realized in the existing local parking area. The development of an optimal energy management system to effectively manage these inputs is realized and the uncertainties pertaining to EVs’ demand are also taken into account. To demonstrate its efficacy, the concept is tested considering a bench of case studies and comprehensive results are obtained.

29 March 2017 in IET Generation, Transmission & Distribution
Verified
Journal Article
Open access
PDF file
Sıtkı GünerSıtkı Güner
Sıtkı Güner
aydogan ozdemiraydogan ozdemir
aydogan ozdemir
Electric vehicles, EVs, provide temporary distributed energy storage capacity for the evolving distribution grid. An aggregated storage capacity of multiple EVs is more meaningful for a distribution grid. Commercial car parks at metropolitan cities and parking lots (PLs) of hospitals, shopping centres, universities etc. are the potential areas that can be organised for these purposes. This study presents a distributed storage capacity formulation of an EV PL that can be used in distribution system reliability improvement. The storage capacity was determined by sequential Monte‐Carlo simulations. Real car arrival‐departure data provided by the PL authority of Istanbul, technical parameters (SoC of the batteries, battery capacity of EVs, charging and discharging rates), and some side‐specific probabilistic parameters (driver behaviour, mean transportation distance etc.) were used for realistic model development. Special attention was given to some critical time periods when the storage support was more crucial for the utility grid. Moreover, future expectations for city urban planning and for travel behaviour of the community were also included in the model. Finally, impacts of several important parameters on the storage capacity of the PL were determined through sensitivity analysis.

27 November 2020 in IEEE Transactions on Sustainable Energy
Verified
Journal Article
Closed access
ISIbrahim Sengor
Ibrahim Sengor
Sıtkı GünerSıtkı Güner
Sıtkı Güner
OEOzan Erdinc
Ozan Erdinc
Thanks to the demand response (DR), the system operators have a substantial opportunity to manipulate the demand side of the power system. Moreover, the system operators can easily incorporate trending technologies such as electric vehicles (EV) due to the idea of introducing improved level of controllable loads. In this study, a real-time optimization-based energy management model for an EV parking lot (EVPL) is propounded by using linear programming. The proposed algorithm offers a peak load limitation oriented DR program providing operational flexibility from the load-serving entity point of view together with the objective of maximizing the load factor of the EVPL in daily operation. Because of the mobility of the EVs, uncertain arrival/departure times along with the state-of-energy levels upon their arrival are generated by considering historical data to ensure a more realistic approach. In order to prove the validness of the suggested optimization model, a bunch of case studies is performed. Besides, credible results and useful findings are found out by activating the propounded model.

22 March 2021 in IEEE Transactions on Transportation Electrification
Verified
Journal Article
Closed access
ZSZhaleh Sadreddini
Zhaleh Sadreddini
Sıtkı GünerSıtkı Güner
Sıtkı Güner
OEOzan Erdinc
Ozan Erdinc
In metropolitans, the problem of finding available parking slots has changed as finding available parking slots having charging stations due to increasing electric vehicle (EV) deployment. Smart management systems can be used in this manner for obtaining an optimum parking slot in EV parking lots (PLs) considering EV users’ preferences. This article proposes a smart reservation system considering the behavior of EV users, parking slot availability (PSA), state-of-charge (SoC) value of EVs, and PL usage history of EV users. In order to handle weighting the behavior of EV users according to a comprehensive criteria comparison, the analytical hierarchy process (AHP) from multicriteria decision-making (MCDM) techniques is used in the smart reservation system. Thereafter, the proposed ranking function is presented to develop the mentioned quality-of-experience (QoE)-based charging slot allocation considering the reservation requests of EV users sent via a mobile application and to accept the optimal EVs in accordance with the weights assigned by AHP. The proposed concept is tested under different cases generated by changing the individual importance degree of EV user’s criteria. The different case studies demonstrate the effectiveness of the proposed decision-based multicriteria reservation system in terms of EV users’ acceptance ratio. Simulation results show that not only the importance degree related to the EV users’ criteria has an important effect in accepting appropriate EV users but also PSA management is another vital criterion especially in peak-load hours.

1 August 2020 in Electric Power Systems Research
Verified
Journal Article
Closed access
Sıtkı GünerSıtkı Güner
Sıtkı Güner
aydogan ozdemiraydogan ozdemir
aydogan ozdemir

18 November 2010 in International Journal of Energy Research
Verified
Journal Article
Closed access
PDF file
IFİrEm Fırtına
İrEm Fırtına
Sıtkı GünerSıtkı Güner
Sıtkı Güner
AAAyhan Albostan
Ayhan Albostan
Fuel cell is a system that converts chemical energy to electrical energy from an oxidation–reduction reaction of hydrogen and oxygen. In this study, Pt/C catalyst, solvent, and a binder agent were mixed to prepare catalyst ink. First, we applied carbon black ink to the carbon paper to supply hydrophobic and hydrophilic structure on its surface, which is called as microporous layer (MPL). Then catalyst ink was deposited on the treated carbon paper to form gas diffusion layers (GDLs) for anode and cathode side of the fuel cell. At this position, catalyst layer surfaces and carbon paper were analyzed by using scanning electron microscopy (SEM) and it was seen by energy dispersive spectroscopy (EDS) analysis that the catalysts were spread uniformly on a carbon paper. A membrane is fixed between GDLs and hot-pressed at 120°C, 75 kg cm− 2 to compose membrane electrode assembly (MEA). In a fuel cell test unit, MEA has internal resistance, which was evaluated by applying current interrupt method and current–voltage curve was drawn by load application. As a result of the test, I-V curves were formed and compared with characteristic curve of commercial MEA. It was seen that the shapes of the curves are similar. Maximum power values are 100, 275, and 390 mW for homemade MEA without MPL, with MPL, and commercial MEA, respectively. MEA without MPL was susceptible to flooding, especially at high-currrent values. MPL is helpful to increase the porosity of the diffusion layer and this effect can improve the oxygen transfer rate and lead to a higher performance. Compared with commercial MEA, homemade MEA did not reach high-current and -power values due to lots of parameters which affects the fuel cell performance as catalyst activity, conditions of MEA preparation, and disorder of measurement conditions, etc. Copyright © 2010 John Wiley & Sons, Ltd.