In this work, we present the improved efficiency of 4H-SiC Schottky barrier diodes-based detectors equipped with the thermal neutron converters. This is achieved by optimizing the thermal neutron converter thicknesses. Simulations of the optimal thickness of thermal neutron converters have been performed using two Monte Carlo codes (Monte Carlo N–Particle Transport Code and Stopping and Range of Ions in Matter). We have used 6LiF and 10B4C for the thermal neutron converter material. We have achieved the thermal neutron efficiency of 4.67% and 2.24% with 6LiF and 10B4C thermal neutron converters, respectively.
1 August 2020 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
We report the response of newly designed 4H-SiC Schottky barrier diode (SBD) detector prototype to alpha and gamma radiation. We studied detectors of three different active area sizes (1 × 1, 2 × 2 and 3 × 3 mm2), while all detectors had the same 4H-SiC epi-layer thickness of approximately µm, sufficient to stop alpha particles up to 6.8 MeV, which have been used in this study. The detector response to the various alpha emitters in the 3.27 MeV to 8.79 MeV energy range clearly demonstrates the excellent linear response to alpha emissions of the detectors with the increasing active area. The detector response in gamma radiation field of Co-60 and Cs-137 sources showed a linear response to air kerma and to different air kerma rates as well, up to 4.49 Gy/h. The detector response is not in saturation for the dose rates lower than 15.3 mGy/min and that its measuring range for gamma radiation with energies of 662 keV, 1.17 MeV and 1.33 MeV is from 0.5 mGy/h–917 mGy/h. No changes to electrical properties of pristine and tested 4H-SiC SBD detectors, supported by a negligible change in carbon vacancy defect density and no creation of other deep levels, demonstrates the radiation hardness of these 4H-SiC detectors.
We report on a bistable defect known as M-center, here introduced in n-type 4H-SiC by 2 MeV He ion implantation. Deep levels of the M-center are investigated by means of junction spectroscopy techniques, namely, deep level transient spectroscopy (DLTS) and isothermal DLTS. In addition to previously reported three deep levels arising from the M-center (labeled as M1, M2, and M3), we provide direct evidence on the existence of a fourth transition (labeled as M4) with an activation energy of 0.86 eV. Activation energies and apparent capture cross sections for all four metastable defects are determined. From first-principles calculations, it is shown that the observed features of the M-center, including the charge state character, transition levels, bi-stability dynamics, and annealing, are all accounted for by a carbon self-interstitial.
We report on the effects of large-area 4H-SiC Schottky barrier diodes on the radiation response to ionizing particles. Two different diode areas were compared: 1 mm × 1 mm and 5 mm × 5 mm. 6LiF and 10B4C films, which were placed on top of the diodes, were used as thermal neutron converters. We achieved a thermal neutron efficiency of 5.02% with a 6LiF thermal neutron converter, which is one of the highest efficiencies reported to date. In addition, a temperature-dependent radiation response to alpha particles was presented. Neutron irradiations were performed in a JSI TRIGA dry chamber and an Am-241 wide-area alpha source was used for testing the alpha response of the 4H-SiC Schottky barrier diodes.