Ahmed Menevseoglu

Mr. Ahmed Menevseoglu

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 December 2023 in Food Control
Verified
Journal Article
Closed access
AMAhmed Menevseoglu
Ahmed Menevseoglu
JEJ.A. Entrenas
J.A. Entrenas
NGNurhan GUNES
Nurhan GUNES
MDM.A. Dogan
M.A. Dogan
DPD. Pérez-Marín
D. Pérez-Marín

18 September 2021 in Sensors
Verified
Journal Article
Open access
PDF file
AMAhmed Menevseoglu
Ahmed Menevseoglu
Didem AykasDidem Aykas
Didem Aykas
BHBeatriz Hatta-Sakoda
Beatriz Hatta-Sakoda
VTVictor Hugo Toledo-Herrera
Victor Hugo Toledo-Herrera
Luis Rodriguez-SaonaLuis Rodriguez-Saona
Luis Rodriguez-Saona
Handheld Raman and portable FT-IR spectroscopy devices were evaluated for fast and non-invasive determination of methanol and ethanol levels in Peruvian Pisco. Commercial Peruvian Pisco (n = 171) samples were kindly provided by the UNALM Alliance for Research in Alcohol and its Derivatives (Lima, Peru) and supplemented by purchases at grocery and online stores. Pisco spectra were collected on handheld Raman spectrometers equipped with either a 1064 nm or a 785 nm excitation laser and a portable infrared unit operating in transmission mode. The alcohol levels were determined by GC–MS. Calibration models used partial least-squares regression (PLSR) to develop prediction algorithms. GC–MS data revealed that 10% of Pisco samples had ethanol levels lower than 38%, indicating possible water dilution. Methanol levels ranged from 10 to 130 mg/100 mL, well below the maximum levels allowed for fruit brandies. Handheld Raman equipped with a 1064 nm excitation laser gave the best results for determining ethanol (SEP = 1.2%; RPre = 0.95) and methanol (SEP = 1.8 mg/100 mL; RPre = 0.93). Randomly selected Pisco samples were spiked with methanol (75 to 2800 mg/100 mL), and their Raman spectra were collected through their genuine commercial bottles. The prediction models gave an excellent performance (SEP = 98 mg/100 mL; RPre = 0.97), allowing for the non-destructive and non-contact determination of methanol and ethanol concentrations without opening the bottles.

1 January 2022 in International Dairy Journal
Verified
Journal Article
Closed access
MOMustafa Ozturk
Mustafa Ozturk
MDMuhammed Ali Dogan
Muhammed Ali Dogan
AMAhmed Menevseoglu
Ahmed Menevseoglu
HAHuseyin Ayvaz
Huseyin Ayvaz

14 June 2020 in Journal of Food Measurement and Characterization
Verified
Journal Article
Closed access
PDF file
AMAhmed Menevseoglu
Ahmed Menevseoglu
SDSEVGİN DIBLAN
SEVGİN DIBLAN
MTMeltem Türkyılmaz
Meltem Türkyılmaz
MÖMehmet Özkan
Mehmet Özkan

8 December 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Didem AykasDidem Aykas
Didem Aykas
Christopher BallChristopher Ball
Christopher Ball
AMAhmed Menevseoglu
Ahmed Menevseoglu
Luis Rodriguez-SaonaLuis Rodriguez-Saona
Luis Rodriguez-Saona
This research demonstrates simultaneous predictions of individual and total sugars in breakfast cereals using a novel, handheld near-infrared (NIR) spectroscopic sensor. This miniaturized, battery-operated unit based on Fourier Transform (FT)-NIR was used to collect spectra from both ground and intact breakfast cereal samples, followed by real-time wireless data transfer to a commercial tablet for chemometric processing. A total of 164 breakfast cereal samples (60 store-bought and 104 provided by a snack food company) were tested. Reference analysis for the individual (sucrose, glucose, and fructose) and total sugar contents used high-performance liquid chromatography (HPLC). Chemometric prediction models were generated using partial least square regression (PLSR) by combining the HPLC reference analysis data and FT-NIR spectra, and associated calibration models were externally validated through an independent data set. These multivariate models showed excellent correlation (Rpre ≥ 0.93) and low standard error of prediction (SEP ≤ 2.4 g/100 g) between the predicted and the measured sugar values. Analysis results from the FT-NIR data, confirmed by the reference techniques, showed that eight store-bought cereal samples out of 60 (13%) were not compliant with the total sugar content declaration. The results suggest that the FT-NIR prototype can provide reliable analysis for the snack food manufacturers for on-site analysis.

20 October 2020 in Journal of Food Measurement and Characterization
Verified
Journal Article
Closed access
PDF file
AMAhmed Menevseoglu
Ahmed Menevseoglu
DADidem Peren Aykas
Didem Peren Aykas
EAEda Adal
Eda Adal