BACKGROUND: The outbreak of COVID-19 caused by a novel Coronavirus (termed SARS-CoV-2) has spread to over 140 countries around the world. Currently, reverse transcription quantitative qPCR (RT-qPCR) is used as the gold standard for diagnostics of SARS-CoV-2. However, the positive rate of RT-qPCR assay of pharyngeal swab samples are reported to vary from 30∼60%. More accurate and sensitive methods are urgently needed to support the quality assurance of the RT-qPCR or as an alternative diagnostic approach. METHODS: We established a reverse transcription digital PCR (RT-dPCR) protocol to detect SARS-CoV-2 on 194 clinical pharyngeal swab samples, including 103 suspected patients, 75 close contacts and 16 supposed convalescents. RESULTS: The limit of blanks (LoBs) of the RT-dPCR assays were ∼1.6, ∼1.6 and ∼0.8 copies/reaction for ORF 1ab, N and E genes, respectively. The limit of detection (LoD) was 2 copies/reaction. For the 103 fever suspected patients, the sensitivity of SARS-CoV-2 detection was significantly improved from 28.2% by RT-qPCR to 87.4% by RT-dPCR. For close contacts, the suspect rate was greatly decreased from 21% down to 1%. The overall sensitivity, specificity and diagnostic accuracy of RT-dPCR were 90%, 100% and 93 %, respectively. In addition, quantification of the viral load for convalescents by RT-dPCR showed that a longer observation period was needed in the hospital for elderly patients. CONCLUSION: RT-dPCR could be a confirmatory method for suspected patients diagnosed by RT-qPCR. Furthermore, RT-dPCR was more sensitive and suitable for low viral load specimens from the both patients under isolation and those under observation who may not be exhibiting clinical symptoms.
20 March 2024 in Analytical and Bioanalytical Chemistry
Background/Aims: Circulating tumor DNA (ctDNA) is becoming a valuable cancer biomarker for clinical decision-making. Nevertheless, the lack of quality control materials to assess the reliability of test results remains a challenge. This study aimed to establish digital PCR (dPCR) assays for detecting TP53 variants (R175H and R248W) and develop a preparation method for ctDNA reference materials to improve detection reliability. Methods: Two dPCR assays targeting TP53-R175H and TP53-R248W variants were developed and validated for repeatability, sensitivity, and linearity. Additionally, a ctDNA reference material preparation protocol was developed by digesting nucleosomes from cultured cancer cell lines with micrococcal nuclease, followed by magnetic beads purification. The size distribution and quality of the generated ctDNA fragments was analyzed, and the developed dPCR assays were applied to detect the variants in the ctDNA samples. Results: The dPCR assays demonstrated high repeatability (RSD of 0.16% to 7.65%) and excellent linearity (R2 values of 1.0000 and 0.9981) across variant allele frequencies of 50%–0.1%. The limits of detection (LOD) and quantification (LOQ) were 0.143% (R175H) and 0.092% (R248W). The ctDNA reference materials exhibited single dominant peaks at 128 bp (R175H) and 143 bp (R248W). The dPCR assays successfully detected variants in these reference materials, confirming their applicability for ctDNA samples. onclusion: Firstly, accurate measurement procedures for TP53-R175H and TP53-R248W variants based on dPCR were established in this study. Furthermore, a protocol for preparing ctDNA reference material was established here. By digesting nucleosomal DNA derived from cancer cell lines with micrococcal nuclease, this method can closely mimic the properties of clinical ctDNA. The dPCR method and ctDNA reference material preparation approach established here could be used in ctDNA detection and for improving its reliability.