Lorin Maletsky

Dr. Lorin Maletsky

orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2007 in Journal of Biomechanics
Verified
Journal Article
Closed access
LMLorin Maletsky
Lorin Maletsky
JSJunyi Sun
Junyi Sun
NMNicholas A. Morton
Nicholas A. Morton

1 February 2005 in Journal of Biomechanical Engineering
Verified
Journal Article
Closed access
PDF file
LMLorin Maletsky
Lorin Maletsky
BHBen M. Hillberry
Ben M. Hillberry
This work describes the design and capabilities of the Purdue Knee Simulator: Mark II and a sagittal-plane model of the machine. This five-axis simulator was designed and constructed to simulate dynamic loading activities on either cadaveric knee specimens or total knee prostheses mounted on fixtures. The purpose of the machine was to provide a consistent, realistic loading of the knee joint, allowing the kinematics and specific loading of the structures of the knee to be determined based on condition, articular geometry, and simulated activity. The sagittal-plane model of the knee simulator was developed both to predict the loading at the knee from arbitrary inputs and to generate the necessary inputs required to duplicate specified joint loading. Measured tibio-femoral compressive force and quadriceps tension were shown to be in good agreement with the predicted loads from the model. A controlled moment about the ankle-flexion axis was also shown to change the loading on the quadriceps.

29 June 2016 in Journal of Biomechanical Engineering
Verified
Journal Article
Closed access
PDF file
MHMichael D. Harris
Michael D. Harris
ACAdam J. Cyr
Adam J. Cyr
AAAzhar A. Ali
Azhar A. Ali
CFClare K. Fitzpatrick
Clare K. Fitzpatrick
PRPaul J. Rullkoetter
Paul J. Rullkoetter
KSKevin B. Shelburne
Kevin B. Shelburne
Modeling complex knee biomechanics is a continual challenge, which has resulted in many models of varying levels of quality, complexity, and validation. Beyond modeling healthy knees, accurately mimicking pathologic knee mechanics, such as after cruciate rupture or meniscectomy, is difficult. Experimental tests of knee laxity can provide important information about ligament engagement and overall contributions to knee stability for development of subject-specific models to accurately simulate knee motion and loading. Our objective was to provide combined experimental tests and finite-element (FE) models of natural knee laxity that are subject-specific, have one-to-one experiment to model calibration, simulate ligament engagement in agreement with literature, and are adaptable for a variety of biomechanical investigations (e.g., cartilage contact, ligament strain, in vivo kinematics). Calibration involved perturbing ligament stiffness, initial ligament strain, and attachment location until model-predicted kinematics and ligament engagement matched experimental reports. Errors between model-predicted and experimental kinematics averaged <2 deg during varus–valgus (VV) rotations, <6 deg during internal–external (IE) rotations, and <3 mm of translation during anterior–posterior (AP) displacements. Engagement of the individual ligaments agreed with literature descriptions. These results demonstrate the ability of our constraint models to be customized for multiple individuals and simultaneously call attention to the need to verify that ligament engagement is in good general agreement with literature. To facilitate further investigations of subject-specific or population based knee joint biomechanics, data collected during the experimental and modeling phases of this study are available for download by the research community.

15 May 2007 in Journal of Orthopaedic Research
Verified
Journal Article
Open access
PDF file
NMNicholas A. Morton
Nicholas A. Morton
LMLorin Maletsky
Lorin Maletsky
SPSaikat Pal
Saikat Pal
PLPeter J. Laz
Peter J. Laz
Small variability associated with identifying and locating anatomical landmarks on the knee has the potential to affect the joint coordinate systems and reported kinematic descriptions. The objectives of this study were to develop an approach to quantify the effect of landmark location variability on both tibiofemoral and patellofemoral kinematics and to identify the critical landmarks and associated degrees of freedom that most affected the kinematic measures. The commonly used three‐cylindric open‐chain kinematic description utilized measured rigid body kinematics from a cadaveric specimen during simulated gait. A probabilistic analysis was performed with 11 anatomical landmarks to predict the variability in each kinematic. The model predicted the absolute kinematic bounds and offset kinematic bounds, emphasizing profile shape, for each kinematic over the gait cycle, as well as the range of motion. Standard deviations of up to 2 mm were assumed for the anatomical landmark locations and resulted in significant variability in clinically relevant absolute kinematic parameters of up to 6.5° and 4.4 mm for tibiofemoral and 7.6° and 6.5 mm for patellofemoral kinematics. The location of the femoral epicondylar prominences had the greatest effect on both the tibiofemoral and patellofemoral kinematic descriptions. A quantitative understanding of the potential changes in kinematic description caused by anatomical landmark variability is important not only to the accuracy of kinematic gait studies and the evaluation of total knee arthroplasty implant performance, but also may impact component placement decision‐making in computer‐assisted surgery. © 2007 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 25:1221–1230, 2007

29 July 2005 in Journal of Biomechanical Engineering
Verified
Journal Article
Closed access
PDF file
TGTrent M. Guess
Trent M. Guess
LMLorin Maletsky
Lorin Maletsky
As a first step towards reproducing desired three-dimensional joint loading and motion on a dynamic knee simulator, the goal of this study was to develop and verify a three-dimensional computational model that generated control profiles for the simulator using desired knee loading and motion as model inputs. The developed model was verified by predicting tibio-femoral loading on an instrumented analog knee for given actuator forces and the ability to generate simulator control profiles was demonstrated using a three-dimensional walking profile. The model predicted axial tibia loading for a sagittal-plane dual-limb squat within 1% of measured peak loading. Adding out-of-sagittal-plane forces decreased the accuracy of load prediction. The model generated control profiles to the simulator that produced axial tibia loading within 16% of desired for walking. Discrepancies in predicted and measured quadriceps forces influenced the accuracy of the generated control profiles. Future work will replace the analog knee in both the model and machine with a prosthetic knee.

1 January 2014 in Journal of Biomechanics
Verified
Journal Article
Closed access
SSSami Shalhoub
Sami Shalhoub
LMLorin Maletsky
Lorin Maletsky