Yau Kei Chan

Dr. Yau Kei Chan

Department of Ophthalmology, The University of Hong Kong, Hong Kong, China
orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 September 2020 in Acta Ophthalmologica
Verified
Journal Article
Closed access
PDF file
YCYing Chen
Ying Chen
VKVictoria R Kearns
Victoria R Kearns
LZLiangyu Zhou
Liangyu Zhou
TSTeresa Sandinha
Teresa Sandinha
WLWai Ching Lam
Wai Ching Lam
Yau Kei ChanYau Kei Chan
Yau Kei Chan

8 June 2015 in ACS Applied Materials & Interfaces
Verified
Journal Article
Closed access
YSYang Song
Yang Song
Yau Kei ChanYau Kei Chan
Yau Kei Chan
QMQingming Ma
Qingming Ma
ZLZhou Liu
Zhou Liu
HSHo Cheung Shum
Ho Cheung Shum

15 February 2022 in Survey of Ophthalmology
Verified
Journal Article
Closed access
MMMarco King In Ma
Marco King In Ma
CSChinmoy Saha
Chinmoy Saha
SPStephanie Hiu Ling Poon
Stephanie Hiu Ling Poon
RYRachel Sze Wan Yiu
Rachel Sze Wan Yiu
KSKendrick Co Shih
Kendrick Co Shih
Yau Kei ChanYau Kei Chan
Yau Kei Chan

1 December 2011 in Investigative Ophthalmology & Visual Science
Verified
Journal Article
Open access
PDF file
Yau Kei ChanYau Kei Chan
Yau Kei Chan
CNChiu On Ng
Chiu On Ng
PKPaul C. Knox
Paul C. Knox
MGMichael J. Garvey
Michael J. Garvey
RWRachel Williams
Rachel Williams
DWDavid Wong
David Wong
Purpose.: Emulsification is an inherent problem of silicone oil used in vitreoretinal surgery. It has been shown that silicone oil can be made more resistant to emulsification and easier to inject by adding high-molecular-weight components (5% or 10% 423-kDa polydimethylsiloxane [PDMS]) to normal 1000 mPa · s silicone oil. The authors hypothesize that this might also reduce the movement of oil within an eye. Methods.: A model eye chamber made of surface-modified poly(methyl methacrylate) was driven by a computer and a stepper motor to mimic saccadic eye movement. Seven silicone oils with different shear and extensional viscosities were tested. Two sets of eye movements were used: (amplitude 9°, angular velocity 390°/s, duration 50 ms) and (amplitude 90 °, angular velocity 360°/s, duration 300 ms). The movements were captured and analyzed by video recording. Results.: The angular velocity of an oil bubble relative to the eye chamber appears to form an exponential relationship with its shear viscosity. Depending on the thickness of the film of aqueous between the eye wall and the oil bubble, the shear rate was estimated to be between 6 and 14 × 104 s−1. The addition of 10% of 423-kDa PDMS to 1000 mPa · s silicone oil significantly reduced the peak relative velocity compared with the base oil of 1000 mPa · s but not 5000 mPa · s. Conclusions.: The addition of high molecular components to a base oil increases its extensional and shear viscosity. Although the extensional viscosity affected the ease with which the oil could be injected, the results showed that it was the shear viscosity that determined the relative velocity between the oil and the wall of the vitreous cavity, and thus the propensity to emulsify.

11 November 2016 in Macromolecular Chemistry and Physics
Verified
Journal Article
Closed access
PDF file
HYHao Yuan
Hao Yuan
QMQingming Ma
Qingming Ma
YSYang Song
Yang Song
MTMatthew Y. H. Tang
Matthew Y. H. Tang
Yau Kei ChanYau Kei Chan
Yau Kei Chan
Ho Cheung (Anderson) ShumHo Cheung (Anderson) Shum
Ho Cheung (Anderson) Shum

25 November 2014 in Graefe's Archive for Clinical and Experimental Ophthalmology
Verified
Journal Article
Closed access
PDF file
Yau Kei ChanYau Kei Chan
Yau Kei Chan
NCNing Cheung
Ning Cheung
WCWing Suet Catherine Chan
Wing Suet Catherine Chan
DWDavid Wong
David Wong