Epoxide hydrolases are attractive and industrially important biocatalysts. They can catalyze the enantioselective hydrolysis of epoxides to the corresponding diols as chiral building blocks for bioactive compounds and drugs. In this review article, we discuss the state of the art and development potential of epoxide hydrolases as biocatalysts based on the most recent approaches and techniques. The review covers new approaches to discover epoxide hydrolases using genome mining and enzyme metagenomics, as well as improving enzyme activity, enantioselectivity, enantioconvergence, and thermostability by directed evolution and a rational design. Further improvements in operational and storage stabilization, reusability, pH stabilization, and thermal stabilization by immobilization techniques are discussed in this study. New possibilities for expanding the synthetic capabilities of epoxide hydrolases by their involvement in non-natural enzyme cascade reactions are described.
Screen-printing technology is a game changer in many fields including electrochemical biosensing. Two-dimensional nanomaterial MXene Ti3C2Tx was integrated as a nanoplatform to immobilise enzyme sarcosine oxidase (SOx) onto the interface of screen-printed carbon electrodes (SPCEs). A miniaturised, portable, and cost-effective nanobiosensor was constructed using chitosan as a biocompatible glue for the ultrasensitive detection of prostate cancer biomarker sarcosine. The fabricated device was characterised with energy-dispersive X-ray spectroscopy (EDX), electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV). Sarcosine was detected indirectly via the amperometric detection of H2O2 formed during enzymatic reaction. The nanobiosensor could detect sarcosine down to 7.0 nM with a maximal peak current output at 4.10 ± 0.35 × 10−5 A using only 100 µL of a sample per measurement. The assay run in 100 μL of an electrolyte showed the first linear calibration curve in a concentration window of up to 5 μM with a slope of 2.86 μA·μM−1, and the second linear calibration curve in the range of 5–50 μM with a slope of 0.32 ± 0.01 μA·μM−1 (R2 = 0.992). The device provided a high recovery index of 92.5% when measuring an analyte spiked into artificial urine, and could be used for detection of sarcosine in urine for at least a period of 5 weeks after the preparation.
A novel immobilization matrix for the entrapment of viable whole-cell Baeyer–Villiger monooxygenase was developed. Viable recombinant Escherichia coli cells overexpressing cyclohexanone monooxygenase were entrapped in polyelectrolyte complex beads prepared by a two-step reaction of oppositely-charged polymers including highly defined cellulose sulphate. Immobilized cells exhibited higher operational stability than free cells during 10 repeated cycles of Baeyer–Villiger biooxidations of rac-bicyclo[3.2.0]hept-2-en-6-one to the corresponding lactones (1R,5S)-3-oxabicyclo-[3.3.0]oct-6-en-3-one and (1S,5R)-2-oxabicyclo-[3.3.0]oct-6-en-3-one. The morphology of polyelectrolyte complex beads was characterised by environmental scanning electron microscopy; the spatial distribution of polymers in the beads and cell viability were examined using confocal laser scanning microscopy, and the texture was characterised by the mechanical resistance measurements.