Zhanwen Zhang

Dr. Zhanwen Zhang


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 February 2024 in European Journal of Nuclear Medicine and Molecular Imaging
Verified
Journal Article
Closed access
PDF file
LLLifang Liu
Lifang Liu
JZJiawei Zhong
Jiawei Zhong
ZZZiqi Zhang
Ziqi Zhang
XYXiaoting Ye
Xiaoting Ye
XWXinlu Wang
Xinlu Wang
ZZZhanwen Zhang
Zhanwen Zhang

13 December 2023 in Gastroenterology Report
Verified
Journal Article
Open access
XZXuneng Zhang
Xuneng Zhang
RZRongqin Zhang
Rongqin Zhang
QZQingyang Zheng
Qingyang Zheng
ZHZichuan He
Zichuan He
BLBing Lan
Bing Lan
HWHuaiming Wang
Huaiming Wang
Background: Colorectal cancer is the third-most common type of cancer. When peritoneal metastasis (PM) develops, diagnosing metastatic lesions is difficult and the prognosis is poor. This study aimed to compare the value of fluorine-18 fibroblast activation protein-specific inhibitor (18F-FAPI-42) and fluorine-18 fluorodeoxyglucose (18F-FDG) positron emission tomography/computed tomography (PET/CT) for detecting PM of colorectal cancer and to guide clinical decision-making. Methods: Forty-eight patients with PM who underwent both 18F-FAPI-42 and 18F-FDG PET/CT examinations were studied. The maximum standardized uptake value (SUV max), tumor-to-background ratios (TBRs) and peritoneal cancer index (PCI) of the PM were compared between the two imaging techniques. The intraclass correlation coefficient (ICC) was used to compare the consistency between the PET/CT PCI score and the intraoperative PCI. A receiver-operating characteristic curve was used to predict the accuracy of CC-0 cytoreduction (complete cytoreduction with no visible disease). Results: The sensitivity and accuracy of 18F-FAPI-42 PET/CT for detecting PM were higher than those of 18F-FDG PET/CT (82.1% vs 61.1%, P < 0.01; 84.6% vs 74.5%, P < 0.01). The median SUV max and TBR of PM was greater in 18F-FAPI-42 than in 18F-FDG PET/CT [4.8 (1.9–20.1) vs 4.7 (1.0–11.0), P = 0.02; 4.3 (1.4–14.6) vs 2.9 (0.6–8.0), P < 0.01, respectively]. The median PCI of PM based on 18F-FAPI-42 PET/CT was greater than that based on 18F-FDG PET/CT (15 vs 9, P < 0.01). The ICC for 18F-FAPI-42 PCI was greater than that for 18F-FDG PCI (0.915 vs 0.724, P < 0.01). The cut-off values of the PCI of the PM for 18F-FAPI-42 and 18F-FDG PET/CT to predict CC-0 were <18 and <10, with areas under the curve of 0.80 and 0.79, respectively. Conclusions: 18F-FAPI-42 PET/CT has superior diagnostic efficacy for PM, particularly in the right upper epigastrium and small intestine. The PCI score of 18F-FAPI-42 PET/CT is very close to the intraoperative PCI score and has a high value for predicting CC-0. The individualized management of PM based on the 18F-FAPI-42 PET/CT PCI score is pivotal.

22 February 2023 in Frontiers in Oncology
Verified
Journal Article
Open access
THTianyuan Hu
Tianyuan Hu
RZRongqin Zhang
Rongqin Zhang
BZBing Zhang
Bing Zhang
SHShanzhen He
Shanzhen He
LLLian Liu
Lian Liu
ZZZhanwen Zhang
Zhanwen Zhang
Occult breast cancer is an uncommon type of breast cancer and its diagnosis is challenging. It is usually invisible on multiple imaging examines. Metastases to the rectum and inguinal lymph nodes from occult breast lobular cancer are even rarer. 68Ga-DOTA peptides can image neuroendocrine tumors by targeting specific somatostatin receptors. Besides, other tumors, including breast cancer, have been shown to express somatostatin receptors. In this case, we presented a 63-year-old woman who underwent both 18F-FDG and 68Ga-DOTATATE PET/CT due to a rectal polyp. An endoscopic excision biopsy confirmed metastatic carcinoma of suspected breast origin, but subsequent ultrasound and MRI showed no signs of malignancy in the breast and adnexa uteri. PET/CT showed obvious 68Ga-DOTATATE activity in bilateral axillary and right inguinal lymph nodes with mild 18F-FDG uptake. Final histopathology at the left axillary, right inguinal lymph nodes, and rectum indicated metastases from breast cancer while the origin remained radiologically occult. Additionally, one uterine fibroids was found with positive uptake of 68Ga-DOTATATE and negative uptake of 18F-FDG. This case suggested that 68Ga-DOTATAE PET/CT may be an effective supplement in diagnosing OBC lymph node metastases with mild 18F-FDG uptake, and it may provide a new technology for the clinical diagnosis of occult breast cancer.

3 August 2024 in Abdominal Radiology
Verified
Journal Article
Closed access
PDF file
BWBing Wang
Bing Wang
THTianyuan Hu
Tianyuan Hu
RSRongfang Shen
Rongfang Shen
LLLian Liu
Lian Liu
JQJunwei Qiao
Junwei Qiao
ZZZhanwen Zhang
Zhanwen Zhang

3 January 2024 in BMC Medical Imaging
Verified
Journal Article
Open access
PDF file
RZRongqin Zhang
Rongqin Zhang
MAMeilinuer Abudurexiti
Meilinuer Abudurexiti
WQWanglin Qiu
Wanglin Qiu
PHPinbo Huang
Pinbo Huang
PHPing Hu
Ping Hu
ZZZhanwen Zhang
Zhanwen Zhang
Background: To validate the feasibility of water enema PET/CT (WE-PET/CT) in incidental colorectal 18F-FDG uptake and improve the accuracy of diagnosing colorectal neoplastic lesions. Methods: We retrospectively analysed the electronic records of 338 patients undergoing common PET/CT and WE-PET/CT at our hospital. PET/CT results were correlated with colonoscopy pathology and follow-up results. The ROC contrast curve was plotted to evaluate the accuracy of SUVmax on common PET/CT and WE-PET/CT for detecting neoplastic lesions. SUVmax and the median retention indexes (RIs) of cancerous, precancerous, and benign lesions and physiologic uptake were compared. Results: The sensitivity, specificity and accuracy of diagnosing neoplastic lesions with common PET/CT were 84.0%, 78.3% and 80.2%, respectively. The corresponding results with WE-PET/CT were 95.8%, 96.5% and 96.2%. The AUC of SUVmax on WE-PET/CT was significantly higher than that on common PET/CT (0.935 vs. 0.524, p < 0.001). The median SUVmax on WE-PET/CT was significantly higher than that on common PET/CT in cancerous and precancerous lesions, and significantly decreased in benign lesions and physiologic uptake (p < 0.001). The RI was significantly different between cancerous lesions and physiologic uptake, between precancerous lesions and physiologic uptake, between benign lesions and physiologic uptake, and between cancerous and benign lesions (p < 0.05). Conclusions: WE-PET/CT is a noninvasive, well-tolerated and effective technique for diagnosing incidental colorectal 18F-FDG uptake. It is helpful for a timely colonoscopy and can effectively avoid an unnecessary colonoscopy for incidental colorectal 18F-FDG uptake.

26 October 2020 in Research Square
Verified
Preprint
Open access
PDF file
GTGanghua Tang
Ganghua Tang
SLShaoyu Liu
Shaoyu Liu
PHPing Hu
Ping Hu
HMHui Ma
Hui Ma
XXXianhong Xiang
Xianhong Xiang
ZZZhanwen Zhang
Zhanwen Zhang
BackgroundThe aim of this study was to evaluate the potential value of 2-[18F]fluoropropionic acid ([18F]FPA) for PET imaging of prostate cancer (PCa) and to confirm the correlation between [18F]FPA accumulation and fatty acid synthase (FASN) levels in PCa models. The results of the first [18F]FPA PET study of a PCa patient are reported.MethodsA PET imaging comparison of [18F]FDG and [18F]FPA was performed in LNCaP, PC-3 and DU145 tumors. Additionally, in vivo blocking experiments in those models were conducted with orlistat. Western blotting staining of FASN were performed in the those xenograft tumors.ResultsThe uptake of [18F]FPA in the LNCaP and PC-3 tumors was higher than that of [18F]FDG (P<0.05 and P<0.05), while [18F]FDG was significantly superior to [18F]FPA in detecting DU145 tumors (P<0.05). Grayscale scanning showed that FASN expression in the LNCaP and PC-3 tumors was 33.3% and 10.3% higher than that in the DU145 tumors, respectively. The accumulation (% ID/g) of [18F]FPA in the LNCaP , PC-3 and DU145 tumors decreased by 27.6, 40.5 and 11.7%, respectively, after treatment with orlistat. The [18F]FPA showed higher tumor/background ratios than [18F]FDG in the first PCa patient (P<0.05).ConclusionsThe [18F]FPA uptake in PCa models was positively correlated with FASN expression and could be reduced after administration of a single FASN inhibitor. In addition, the [18F]FPA is a potential broad-spectrum PET imaging agent, and the imaging effect of [18F]FPA may be superior to [18F]FDG in human PCa.