Michael W Vannier

Prof. Michael W Vannier

orcid

Research Focus & Metrics

Academic Career Length

48Years (1979-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 1997 in Nature
Verified
Journal Article
Closed access
WDWayne C. Drevets
Wayne C. Drevets
JPJoseph L. Price
Joseph L. Price
JSJoseph R. Simpson
Joseph R. Simpson
RTRichard D. Todd
Richard D. Todd
TRTheodore Reich
Theodore Reich
MRMarcus E. Raichle
Marcus E. Raichle

30 April 1996 in Proceedings of the National Academy of Sciences
Verified
Journal Article
Closed access
YSY I Sheline
Y I Sheline
PWP W Wang
P W Wang
MGM H Gado
M H Gado
JCJ G Csernansky
J G Csernansky
MVMichael W Vannier
Michael W Vannier
Hippocampal volumes of subjects with a history of major depressive episodes but currently in remission and with no known medical comorbidity were compared to matched normal controls by using volumetric magnetic resonance images. Subjects with a history of major depression had significantly smaller left and right hippocampal volumes with no differences in total cerebral volumes. The degree of hippocampal volume reduction correlated with total duration of major depression. In addition, large (diameter > or = 4.5 mm)-hippocampal low signal foci (LSF) were found within the hippocampus, and their number also correlated with the total number of days depressed. These results suggest that depression is associated with hippocampal atrophy, perhaps due to a progressive process mediated by glucocorticoid neurotoxicity.

1 December 2009 in Inverse Problems
Verified
Journal Article
Closed access
XPXiaochuan Pan
Xiaochuan Pan
ESEmil Y Sidky
Emil Y Sidky
MVMichael W Vannier
Michael W Vannier
Despite major advances in x-ray sources, detector arrays, gantry mechanical design and especially computer performance, one component of computed tomography (CT) scanners has remained virtually constant for the past 25 years—the reconstruction algorithm. Fundamental advances have been made in the solution of inverse problems, especially tomographic reconstruction, but these works have not been translated into clinical and related practice. The reasons are not obvious and seldom discussed. This review seeks to examine the reasons for this discrepancy and provides recommendations on how it can be resolved. We take the example of field of compressive sensing (CS), summarizing this new area of research from the eyes of practical medical physicists and explaining the disconnection between theoretical and application-oriented research. Using a few issues specific to CT, which engineers have addressed in very specific ways, we try to distill the mathematical problem underlying each of these issues with the hope of demonstrating that there are interesting mathematical problems of general importance that can result from in depth analysis of specific issues. We then sketch some unconventional CT-imaging designs that have the potential to impact on CT applications, if the link between applied mathematicians and engineers/physicists were stronger. Finally, we close with some observations on how the link could be strengthened. There is, we believe, an important opportunity to rapidly improve the performance of CT and related tomographic imaging techniques by addressing these issues.

15 November 2022 in Nature Machine Intelligence
Verified
Journal Article
Closed access
PDF file
Ge WangGe Wang
Ge Wang
ABAndreu Badal
Andreu Badal
XJXun Jia
Xun Jia
JMJonathan S. Maltz
Jonathan S. Maltz
KMKlaus Mueller
Klaus Mueller
RZRongping Zeng
Rongping Zeng

1 January 1996 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
Ge WangGe Wang
Ge Wang
DSD.L. Snyder
D.L. Snyder
JOJ.A. O'Sullivan
J.A. O'Sullivan
MVMichael W Vannier
Michael W Vannier
Iterative deblurring methods using the expectation maximization (EM) formulation and the algebraic reconstruction technique (ART), respectively, are adapted for metal artifact reduction in medical computed tomography (CT). In experiments with synthetic noise-free and additive noisy projection data of dental phantoms, it is found that both simultaneous iterative algorithms produce superior image quality as compared to filtered backprojection after linearly fitting projection gaps. Furthermore, the EM-type algorithm converges faster than the ART-type algorithm in terms of either the I-divergence or Euclidean distance between ideal and reprojected data in the authors' simulation. Also, for a given iteration number, the EM-type deblurring method produces better image clarity but stronger noise than the ART-type reconstruction. The computational complexity of EM- and ART-based iterative deblurring is essentially the same, dominated by reprojection and backprojection. Relevant practical and theoretical issues are discussed.

1 January 1985 in Radiology
Verified
Journal Article
Closed access
MVMichael W Vannier
Michael W Vannier
RBR L Butterfield
R L Butterfield
DJD Jordan
D Jordan
WMW A Murphy
W A Murphy
RLR G Levitt
R G Levitt
MGM Gado
M Gado
Magnetic resonance (MR) imaging systems produce spatial distribution estimates of proton density, relaxation time, and flow, in a two dimensional matrix form that is analogous to that of the image data obtained from multispectral imaging satellites. Advanced NASA satellite image processing offers sophisticated multispectral analysis of MR images. Spin echo and inversion recovery pulse sequence images were entered in a digital format compatible with satellite images and accurately registered pixel by pixel. Signatures of each tissue class were automatically determined using both supervised and unsupervised classification. Overall tissue classification was obtained in the form of a theme map. In MR images of the brain, for example, the classes included CSF, gray matter, white matter, subcutaneous fat, muscle, and bone. These methods provide an efficient means of identifying subtle relationships in a multi-image MR study.