Zipeng Liang

Mr. Zipeng Liang


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 April 2019 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
Sideng HuSideng Hu
Sideng Hu
MXMufeng Xiong
Mufeng Xiong
ZLZipeng Liang
Zipeng Liang
HXHe Xiangning
He Xiangning
This paper proposes a torque distributed control strategy for the multiphase machines in the hybrid energy storage system (HESS) application. Different with the conventional energy current regulation method, the system energy management is researched by the machine torque distribution in different sets of windings. The load power is then afforded by the energy storage devices connected with the windings through the inverters. The principle of the distributed torque operation is explored with a dual three-phase PMSM model and the asymmetrical windings operation is explained with the flux vector diagram. The windings decoupling compensation, flux observer and parameter identification methods are presented. Based on the proposed strategy, a power frequency dividing coordinated regulation is achieved. The hybrid energy storage devices can directly response to the average or instantaneous parts in the load torque and power fluctuation. Simulation and experiments are demonstrated with different operation cases.

9 April 2019 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
ZLZipeng Liang
Zipeng Liang
Sideng HuSideng Hu
Sideng Hu
HXHe Xiangning
He Xiangning
Devices and the passive components in the single-phase impedance source network converter are sensitive to the double-line-frequency (DLF) pulsation. Previous research works have studied the power decoupling and the DLF equivalent model for the power pulsation suppression method. This paper explored the DLF transfer routes in the impedance source network. A comprehensive stress derivation of the passive components and switching devices are obtained for the suppression method enhancement and optimization. For the DLF passive suppression method, the explanation for the passive component volume issue is provided from the stress aspect. The component value solution space and corresponding design guidance are presented. For the DLF active suppression method (ASM), a buck-type dc-side ASM suppression method is employed and its optimization is demonstrated with the assistant circuit stress analysis. The total capacitor and inductor values get reduced by 77% and 25%, respectively. The corresponding pulsewidth modulation method implementation and the common-mode leakage current demonstration are also presented. The effectiveness of the theoretical analysis and optimization methods is verified by simulations and experiments.

23 January 2017 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
Sideng HuSideng Hu
Sideng Hu
ZLZipeng Liang
Zipeng Liang
YWYujie Wang
Yujie Wang
Jing ZhouJing Zhou
Jing Zhou
HXHe Xiangning
He Xiangning
For maximizing the power transfer in an inductive power transfer system, the operating frequency of the system is normally designed to be the same as the resonant frequency of the secondary power pick-up. But the load deviation reflected from secondary side to primary side will result in the frequency mismatch issue. Therefore, the contactless load detection technique is significant to ensure the power transfer efficiency and capacity. The emerging technique taking advantages of the amplitude decay rate in a transient process is promising. The robustness and practicability can get enhanced and the complicated steady circuit model is avoided. However, the accuracy for the small resistance application is still a challenge even with sophisticated compensation algorithms. This paper classified the system detectable region through the root locus method. The transient process in different subregions is excavated mathematically. It is revealed that the variation of the system from the second order to fourth order is the key issue for the detection error in the small load resistance application. The analysis brings out a novel automatic contactless load detection method to extend the detection range. Both simulation and experimental results verified the effectiveness of the proposed theory and detection method.

12 November 2020 in Energies
Verified
Journal Article
Open access
PDF file
Sideng HuSideng Hu
Sideng Hu
ZLZipeng Liang
Zipeng Liang
Jing ZhouJing Zhou
Jing Zhou
XYXiaoli Yu
Xiaoli Yu
In this paper, the interaction between the energy storage (ES) power distribution and system efficiency enhancement is researched based on the energy stored quasi-Z-source inverter. The corresponding current counteraction, stress reduction, power loss profile, and efficiency enhancement around the embedded energy storage units are studied in details. Firstly, the current counteraction effect on the device current is presented with the embedded ES source. The corresponding reduction in the device current stress is revealed. Then, the detailed device power loss expressions with current redistribution in the impedance network are explored mathematically. A quasi-inverted-trapezoidal power loss profile is found with the embedded source power distribution. To further increase the overall system efficiency, an optimal energy efficiency tracking strategy is proposed for the ES-qZSI (energy-stored quasi-Z-source inverter) based on the power distribution control. Both the simulation and the experiment verified that the power loss is reduced by over 40% through the proposed efficiency enhancement method. The device current and loss analysis for the embedding of energy storage can also be extended to the operating range optimization in other ES systems.

3 December 2018 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
ZLZipeng Liang
Zipeng Liang
Sideng HuSideng Hu
Sideng Hu
HYHuan YANG
Huan YANG
HXHe Xiangning
He Xiangning